Yafeng Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yafeng Li has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Xi Zhang
Department of Traumatology and Orthopedics, Tianjin Hospital, China
8 shared publicationsJing Zhang
School of Mechanical Engineering, Purdue University, Indianapolis, IN 46202, USA; School of Materials Engineering, Purdue University, Indianapolis, IN 46202, USA
7 shared publicationsZichun Zou
School of Mechanical Engineering, Tiangong University, Tianjin 300387, China; Tianjin Key Laboratory of Advanced Mechatronics Equipment Technology, Tiangong University, Tianjin 300387, China
6 shared publicationsZhifeng Tian
Traumatic Orthopedics, Tianjin Hexi District Liulin Hospital, Tianjin, 300222, China
5 shared publicationsBopeng Zhang
School of Mechanical Engineering, Tiangong University, Tianjin, 300387, China
4 shared publicationsFengyuan Lu
School of Mechanical Engineering, Tiangong University, Tianjin 300387, China; Tianjin Key Laboratory of Advanced Mechatronics Equipment Technology, Tiangong University, Tianjin 300387, China
4 shared publications
Latest Publications
- 2 November 2026
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Fluid-solid coupled biomechanical analysis of implants and the microenvironment in Pauwels type III fractures
Pauwels type III femoral neck fractures are characterized by a steep fracture orientation and substantial shear loading. Increasing knee flexion during loaded activities alters hip joint loading and may affect both fixation mechanics and the poroelastic behavior of the interfragmentary healing tissue. How these effects differ among fixation constructs and postoperative tissue states remains unclear. This study compared cannulated compression screws (CCS), the dynamic hip screw (DHS), and the femoral neck system (FNS) using poroelastic finite element models based on Biot’s theory, with material properties representing two postoperative tissue states nominally corresponding to 1 and 12 weeks postoperatively. Hip joint reaction forces obtained from musculoskeletal simulations of squatting for the study subject were applied under five loading conditions corresponding to prescribed knee flexion targets of 60°, 75°, 90°, 105°, and 120°. The results showed that under the condition representing 1 week after surgery and at a prescribed knee flexion target of 120°, implant stresses were 1175.38, 928.77, and 634.35 MPa for CCS, DHS, and FNS, respectively, with FNS exhibiting lower stress than CCS and DHS. The early tissue state also produced large localized principal strain and pronounced pore pressure gradients. Under the 12-week condition, implant stresses decreased below 162 MPa and tissue strain remained below 0.013, although peak pore pressure was higher. The higher assigned tissue stiffness enhanced load sharing and reduced deformation. Overall, knee flexion and tissue state jointly affected fixation mechanics and the local poroelastic behavior, providing a biomechanical insight for postoperative load evaluation.
- 2 November 2026
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Fluid-solid coupled biomechanical analysis of implants and the microenvironment in Pauwels type III fractures
Pauwels type III femoral neck fractures are characterized by a steep fracture orientation and substantial shear loading. Increasing knee flexion during loaded activities alters hip joint loading and may affect both fixation mechanics and the poroelastic behavior of the interfragmentary healing tissue. How these effects differ among fixation constructs and postoperative tissue states remains unclear. This study compared cannulated compression screws (CCS), the dynamic hip screw (DHS), and the femoral neck system (FNS) using poroelastic finite element models based on Biot’s theory, with material properties representing two postoperative tissue states nominally corresponding to 1 and 12 weeks postoperatively. Hip joint reaction forces obtained from musculoskeletal simulations of squatting for the study subject were applied under five loading conditions corresponding to prescribed knee flexion targets of 60°, 75°, 90°, 105°, and 120°. The results showed that under the condition representing 1 week after surgery and at a prescribed knee flexion target of 120°, implant stresses were 1175.38, 928.77, and 634.35 MPa for CCS, DHS, and FNS, respectively, with FNS exhibiting lower stress than CCS and DHS. The early tissue state also produced large localized principal strain and pronounced pore pressure gradients. Under the 12-week condition, implant stresses decreased below 162 MPa and tissue strain remained below 0.013, although peak pore pressure was higher. The higher assigned tissue stiffness enhanced load sharing and reduced deformation. Overall, knee flexion and tissue state jointly affected fixation mechanics and the local poroelastic behavior, providing a biomechanical insight for postoperative load evaluation.
- 18 March 2026
- Published by Springer Nature in Applied Physics A
- Vol. 132 (4) , 300
Fracture mechanisms of ceramics with intersecting defects under uniaxial compressive loading using discrete element method
- 18 March 2026
- Published by Springer Nature in Applied Physics A
- Vol. 132 (4) , 300
Fracture mechanisms of ceramics with intersecting defects under uniaxial compressive loading using discrete element method
- 16 December 2025
- Published by Elsevier in Journal of Orthopaedics
- Vol. 73, 198-205
Biomechanical analysis of femoral stress response during squatting: A combined multibody dynamics and finite element approach
- 16 December 2025
- Published by Elsevier in Journal of Orthopaedics
- Vol. 73, 198-205
Biomechanical analysis of femoral stress response during squatting: A combined multibody dynamics and finite element approach
- 13 December 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 196, 113110
Corrigendum to “Analysis of intrinsic contributing factors in geriatric tibial plateau fractures using extended finite element method” [J. Biomech. 194 (2026) 113060]
- 13 December 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 196, 113110
Corrigendum to “Analysis of intrinsic contributing factors in geriatric tibial plateau fractures using extended finite element method” [J. Biomech. 194 (2026) 113060]
- 6 November 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 194, 113060
Analysis of intrinsic contributing factors in geriatric tibial plateau fractures using extended finite element method
- 6 November 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 194, 113060
Analysis of intrinsic contributing factors in geriatric tibial plateau fractures using extended finite element method
- 13 May 2025
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 141 (1) , 104359
Non-uniform assignment method for skeletal materials based on slope difference distribution and experimental validation
A modeling method of non-uniform material assignment based on Slope Difference Distribution (SDD) is proposed to establish a complete and effective finite element (FE) model of the lower limb tibia. The validity and accuracy of the model based on in vitro mechanical experiments are verified. An initial tibia model was established based on Computed Tomography (CT) images. The numerical distribution of the extracted Hounsfield Unit histograms of the tibia mesh elements was fitted as a smooth curve. The critical point of the slope difference distribution curve was computed and selected to establish a tibia FE model with non-uniform material properties through numerical variations. The composite tibia's area of interest was subjected to data acquisition and analysis of displacement and strain at three gaits through a Digital Image Correlation (DIC) device. The slopes of the stress-strain straight fitting lines for slope difference distribution and structural FE models are 47.17 and 36.45. A comparison of the results of the previous experiments revealed that the FE model based on the material assignment method of slope difference distribution is more accurate. The assignment method is not limited to tibia models but also provides a method for modeling other human bones and reduces the cost of mechanical testing for accurate prediction in the simulation of bone biomechanics.
- 13 May 2025
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 141 (1) , 104359
Non-uniform assignment method for skeletal materials based on slope difference distribution and experimental validation
A modeling method of non-uniform material assignment based on Slope Difference Distribution (SDD) is proposed to establish a complete and effective finite element (FE) model of the lower limb tibia. The validity and accuracy of the model based on in vitro mechanical experiments are verified. An initial tibia model was established based on Computed Tomography (CT) images. The numerical distribution of the extracted Hounsfield Unit histograms of the tibia mesh elements was fitted as a smooth curve. The critical point of the slope difference distribution curve was computed and selected to establish a tibia FE model with non-uniform material properties through numerical variations. The composite tibia's area of interest was subjected to data acquisition and analysis of displacement and strain at three gaits through a Digital Image Correlation (DIC) device. The slopes of the stress-strain straight fitting lines for slope difference distribution and structural FE models are 47.17 and 36.45. A comparison of the results of the previous experiments revealed that the FE model based on the material assignment method of slope difference distribution is more accurate. The assignment method is not limited to tibia models but also provides a method for modeling other human bones and reduces the cost of mechanical testing for accurate prediction in the simulation of bone biomechanics.
- 24 August 2024
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 238 (8-9) , 897-908
Computational analysis of the biomechanical stability of internal fixation of the lateral tibial plateau fracture: A mechanical stability study
The selection of internal fixation as the primary fixation modality for the patient is one of the challenges for the surgeon treating the patient in question. A model of the lateral tibial plateau fracture was established. Three different configurations of internal fixators namely L bone plate, T bone plate, and screw-washer were analyzed. Three stages after surgery were simulated to assess the displacement of bone plates, screws, washers, and the stress shielding ratio in the fracture area. At three stages after surgery, the T bone plate showed better stability for patients during rehabilitation compared with the remaining two schemes, and the screw-washer scheme was the least stable due to the larger internal fixation displacement and stress shielding ratio in the fracture area. In contrast, the L bone plate scheme showed better stability in the early stages after surgery but was second only to the screw-washer scheme in the middle and late stages after surgery. The T bone plate showed better stability and became a new selection for surgeons to treat related patients. At three stages after surgery, the T bone plate has better biomechanical stability compared to the L bone plate and screw-washer schemes.
- 24 August 2024
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 238 (8-9) , 897-908
Computational analysis of the biomechanical stability of internal fixation of the lateral tibial plateau fracture: A mechanical stability study
The selection of internal fixation as the primary fixation modality for the patient is one of the challenges for the surgeon treating the patient in question. A model of the lateral tibial plateau fracture was established. Three different configurations of internal fixators namely L bone plate, T bone plate, and screw-washer were analyzed. Three stages after surgery were simulated to assess the displacement of bone plates, screws, washers, and the stress shielding ratio in the fracture area. At three stages after surgery, the T bone plate showed better stability for patients during rehabilitation compared with the remaining two schemes, and the screw-washer scheme was the least stable due to the larger internal fixation displacement and stress shielding ratio in the fracture area. In contrast, the L bone plate scheme showed better stability in the early stages after surgery but was second only to the screw-washer scheme in the middle and late stages after surgery. The T bone plate showed better stability and became a new selection for surgeons to treat related patients. At three stages after surgery, the T bone plate has better biomechanical stability compared to the L bone plate and screw-washer schemes.
- 15 July 2024
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 47 (4) , 1461-1468
Finite element simulation of treatment with locking plate for distal fibula fractures
An improved Finite Element Model(FEM) is applied to compare the biomechanical stability of plates with three different options in the treatment of distal fibula fractures in this study. The Computed Tomography(CT) scan of the knee to ankle segment of a volunteer was performed. A 3D fibula FEM was reconstructed based on the CT data. Three different loads (uni-pedal standing, torsion, and twisting) were applied, the same as in the experiments in the literature. The stresses and strains of the three options were compared under the same loads, using a 4-hole locking plate (Option A), a 5-hole locking plate (Option B), and a 6-hole locking plate (Option C) in a standard plate for lateral internal fixation. The simulation results show that all three options showed a stress masking effect. Option C had the best overall biomechanical performance and could effectively distribute the transferred weight. This is because option C has greater torsional stiffness and better biomechanical stability than options A and B, and therefore, option C is the recommended internal fixation method for distal fibula fractures. The Finite Element Analysis(FEA) method developed in this work applies to the stress analysis of fracture treatment options in other body parts.
- 15 July 2024
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 47 (4) , 1461-1468
Finite element simulation of treatment with locking plate for distal fibula fractures
An improved Finite Element Model(FEM) is applied to compare the biomechanical stability of plates with three different options in the treatment of distal fibula fractures in this study. The Computed Tomography(CT) scan of the knee to ankle segment of a volunteer was performed. A 3D fibula FEM was reconstructed based on the CT data. Three different loads (uni-pedal standing, torsion, and twisting) were applied, the same as in the experiments in the literature. The stresses and strains of the three options were compared under the same loads, using a 4-hole locking plate (Option A), a 5-hole locking plate (Option B), and a 6-hole locking plate (Option C) in a standard plate for lateral internal fixation. The simulation results show that all three options showed a stress masking effect. Option C had the best overall biomechanical performance and could effectively distribute the transferred weight. This is because option C has greater torsional stiffness and better biomechanical stability than options A and B, and therefore, option C is the recommended internal fixation method for distal fibula fractures. The Finite Element Analysis(FEA) method developed in this work applies to the stress analysis of fracture treatment options in other body parts.
- 18 January 2024
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 238 (2) , 207-218
Finite element model with realistic bone geometries for the optimal design of internal fixation during the fibula healing process
A finite element model with realistic bone geometries is developed to design optimal internal fixation during the fibula healing process in this study. The effect of bone plate parameters on fibula fracture healing is studied. The relationship between differences in plate length, thickness and working length, and bone healing performance is focused. The optimal combination form of the bone plate parameters was selected by the orthogonal experimental design and fracture block strain to achieve bone healing maximize the performance. The model results show that the maximum equivalent force of the bone plate was below the material yield limit; the higher mean contact stresses in the bone fragments indicate that the bone plate is prone to higher contact stresses when they are long. The working length of the bone plate has a greater effect on callus healing than the thickness and length of the bone plate. The optimal internal fixation option for distal fibula fractures is achieved when it provides the stability required for internal fixation during bone healing. It ensures lower contact stresses in the fibula as well as maximum Young’s modulus during callus healing process.
- 18 January 2024
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 238 (2) , 207-218
Finite element model with realistic bone geometries for the optimal design of internal fixation during the fibula healing process
A finite element model with realistic bone geometries is developed to design optimal internal fixation during the fibula healing process in this study. The effect of bone plate parameters on fibula fracture healing is studied. The relationship between differences in plate length, thickness and working length, and bone healing performance is focused. The optimal combination form of the bone plate parameters was selected by the orthogonal experimental design and fracture block strain to achieve bone healing maximize the performance. The model results show that the maximum equivalent force of the bone plate was below the material yield limit; the higher mean contact stresses in the bone fragments indicate that the bone plate is prone to higher contact stresses when they are long. The working length of the bone plate has a greater effect on callus healing than the thickness and length of the bone plate. The optimal internal fixation option for distal fibula fractures is achieved when it provides the stability required for internal fixation during bone healing. It ensures lower contact stresses in the fibula as well as maximum Young’s modulus during callus healing process.
- Open Access
- 30 October 2023
- Published by Elsevier in Computational Particle Mechanics
- Vol. 11 (4) , 1565-1577
Discrete element model for cracking in defective ceramics under uniaxial compression
- 30 October 2023
- Published by Elsevier in Computational Particle Mechanics
- Vol. 11 (4) , 1565-1577
Open AccessDiscrete element model for cracking in defective ceramics under uniaxial compression