Optimal Balance between Heating, Cooling and Environmental Impacts: A Method for Appropriate Assessment of Building Envelope’s U-Value
Open Access
Abstract
In Europe, the recent application of regulations oriented to zero-energy buildings and climate neutrality in 2050 has led to a reduction in energy consumption for heating and cooling in the construction sector. The thermal insulation of the building envelope plays a key role in this process and the requirements about the maximum allowable thermal transmittance are defined by country-specific guidelines. Typically, high insulation values provide low energy consumption for heating; however, they may also entail a risk of overheating in summer period and thus negatively affect the overall performance of the building. In addition, the embodied energy and related emissions caused by the manufacturing and transportation processes of thermal insulation cannot be further neglected in the evaluation of the best optimal solution. Therefore, this paper aims to evaluate the influence in terms of embodied and operational energy of various walls’ thermal insulation thicknesses on residential buildings in Europe. To this end, the EnergyPlus engine was used for the energy simulation within the Ladybug and Honeybee tools, by parametrically conducting multiple iterations; 53 variations of external wall U-value, considering high- and low-thermal-mass scenarios, were simulated for 100 representative cities of the European context, using a typical multifamily building as a reference. The results demonstrate that massive walls generally perform better than lightweight structures and the best solution in terms of energy varies according to each climate. Accordingly, the wall’s thermal transmittance for the samples of Oslo, Bordeaux, Rome and Almeria representative of the Continental, oceanic temperate, Mediterranean, and hot, semi-arid climates were, respectively: 0.12, 0.26, 0.42, and 0.64 W/m2K. The optimal solutions are graphically reported on the map of Europe according to specific climatic features, providing a guidance for new constructions and building retrofit.Keywords
All Related Versions
Funding Information
- EU Research and Innovation programme Horizon 2020 (768921—HEART)
This publication has 22 references indexed in Scilit:
- Evaluation of the optimal thermal insulation thickness for an office building in different climates by means of the basic and modified “cost-optimal” methodologyJournal of Building Engineering, 2019
- Retrofitting a Building’s Envelope: Sustainability Performance of ETICS with ICB or EPSApplied Sciences, 2019
- How can life cycle thinking support sustainability of buildings? Investigating life cycle assessment applications for energy efficiency and environmental performanceJournal of Cleaner Production, 2018
- Assessment of Energetic, Economic and Environmental Performance of Ground-Coupled Heat PumpsEnergies, 2018
- Integrated life cycle assessment and thermodynamic simulation of a public building’s envelope renovation: Conventional vs. Passivhaus proposalApplied Energy, 2018
- Thermal inertia and energy efficiency – Parametric simulation assessment on a calibrated case studyApplied Energy, 2015
- Optimization of thermal insulation to achieve energy savings in low energy house (refurbishment)Energy Conversion and Management, 2014
- Life cycle energy analysis of a residential building with different envelopes and climates in Indian contextApplied Energy, 2012
- Updated world map of the Köppen-Geiger climate classificationHydrology and Earth System Sciences, 2007
- Energy use in the life cycle of conventional and low-energy buildings: A review articleEnergy and Buildings, 2007