The accuracies of three intraoral scanners with regard to shade determination: An in vitro study
- 10 August 2022
- journal article
- research article
- Published by Wiley in Journal of Prosthodontics
- Vol. 32 (5) , 111-117
Abstract
Purpose: To compare the accuracies of three intraoral scanners for shade determination function in vitro, and to preliminarily investigate the shade‐matching characteristics of the three intraoral scanners.Materials and Methods: The shade of the middle third region of each shade tab on the Vita Classical A1‐D4 shade guide (VC) was measured with a spectrophotometer (Vita Easyshade V, VE) and three intraoral scanners, including CEREC Omnicam (OM), 3Shape TRIOS 3 (T3), and TRIOS 4 (T4). A conversion table between VC values and CIELAB values was established from the database of VE to analyze the trueness. The reproducibility of the instruments was then compared by repeating the measurements five times.Results: The mean color difference for each instrument was highest in the OM, followed by the T4, and lowest in the T3 and VE, respectively. The L* and a* value for OM, and the b* value for T4, were significantly different from those for VE (p <0.05). The reproducibility of the instrument was highest in the VE (Fleiss’ kappa: 0.95), followed by the T3 (Fleiss’ kappa: 0.89), T4 (Fleiss’ kappa: 0.87), and OM (Fleiss’ kappa: 0.78).Conclusions: Of the three intraoral scanners, the trueness was best on the T3. The reproducibility of all the instruments was excellent.Keywords
This publication has 51 references indexed in Scilit:
- Recent advances in dental optics – Part I: 3D intraoral scanners for restorative dentistryOptics and Lasers in Engineering, 2014
- Randomized multi-centre study on the effect of training on tooth shade matchingJournal of Dentistry, 2013
- A comparison of Cohen’s Kappa and Gwet’s AC1 when calculating inter-rater reliability coefficients: a study conducted with personality disorder samplesBMC Medical Research Methodology, 2013
- Visual and instrumental evaluation of color match ability of 2 shade guides on a ceramic systemThe Journal of Prosthetic Dentistry, 2012
- Dental color matching instruments and systems. Review of clinical and research aspectsJournal of Dentistry, 2010
- Reliability and accuracy of four dental shade-matching devicesThe Journal of Prosthetic Dentistry, 2009
- Performance assessment of dental shade guidesJournal of Dentistry, 2009
- Color measurement in dentistryJournal of Dentistry, 2009
- Color distribution of a shade guide in the value, chroma, and hue scaleThe Journal of Prosthetic Dentistry, 2008
- Performance Assessment of Colorimetric Devices on Dental PorcelainsJournal of Dental Research, 1989