Yong Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yong Wang has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Yongsheng Zhou
Peking University School and Hospital of Stomatology
6 shared publications - Yuchun Sun
Chinese Academy of Medical Sciences & NMPA Key Laboratory for Dental Materials
6 shared publications - Hongqiang Ye
Department of Prosthodontics, Peking University School and Hospital of Stomatology, National Center of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, No. 22 Zhongguancun South Avenue, Haidian District, Beijing, China, 86 13066994235
4 shared publications - Hu Chen
Chinese Academy of Medical Sciences
3 shared publications - Hefei Bai
Chinese Academy of Medical Sciences
2 shared publications Hefei Bai
Center of Digital Dentistry Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology & NHC Key Laboratory of Digital Stomatology (Key Laboratory of Digital Stomatology Chinese Academy of Medical Sciences) Beijing P. R. China
1 shared publication
Latest Publications
- 21 September 2024
- Published by Wiley in Journal of Prosthodontics
- Vol. 33 (9) , 869-877
Template‐aided and freehand guiding plane preparation for removable partial dentures: A randomized controlled trial
Purpose: To evaluate the accuracy of guiding plane preparation for removable partial dentures (RPDs) using 3D‐printed templates compared to the freehand method.Materials and Methods: Twenty partially edentulous patients requiring RPDs were randomly divided into two groups: the template‐aided group (n = 10) and the freehand group (n = 10). Fifty‐six guiding planes were prepared by a single clinician using two different methods. The angle deviation between the prepared guiding plane and the RPD path of placement was measured for both groups. The 3D deviations between the prepared guiding plane and the designed guiding plane were measured for the template‐aided group. Patient satisfaction with the RPD was evaluated 2 weeks post‐RPD wearing.Results: The angular deviation observed in the template‐aided group (1.77±1.11 degrees) was significantly lower than that (6.29±4.18 degrees) in the freehand group (p < .001). Additionally, the 3D deviation between the prepared guiding plane and the designed guiding plane of the template‐aided group was 106.2±40.9 µm. No significant difference in patient satisfaction scores related to RPD wearing was found between the two groups.Conclusions: Utilizing the cobalt‐chromium (CoCr) alloy template significantly improved the accuracy of guiding plane preparation in the clinic, irrespective of the site of the abutment tooth.
- 21 September 2024
- Published by Wiley in Journal of Prosthodontics
- Vol. 33 (9) , 869-877
Template‐aided and freehand guiding plane preparation for removable partial dentures: A randomized controlled trial
Purpose: To evaluate the accuracy of guiding plane preparation for removable partial dentures (RPDs) using 3D‐printed templates compared to the freehand method.Materials and Methods: Twenty partially edentulous patients requiring RPDs were randomly divided into two groups: the template‐aided group (n = 10) and the freehand group (n = 10). Fifty‐six guiding planes were prepared by a single clinician using two different methods. The angle deviation between the prepared guiding plane and the RPD path of placement was measured for both groups. The 3D deviations between the prepared guiding plane and the designed guiding plane were measured for the template‐aided group. Patient satisfaction with the RPD was evaluated 2 weeks post‐RPD wearing.Results: The angular deviation observed in the template‐aided group (1.77±1.11 degrees) was significantly lower than that (6.29±4.18 degrees) in the freehand group (p < .001). Additionally, the 3D deviation between the prepared guiding plane and the designed guiding plane of the template‐aided group was 106.2±40.9 µm. No significant difference in patient satisfaction scores related to RPD wearing was found between the two groups.Conclusions: Utilizing the cobalt‐chromium (CoCr) alloy template significantly improved the accuracy of guiding plane preparation in the clinic, irrespective of the site of the abutment tooth.
- 10 August 2022
- Published by Wiley in Journal of Prosthodontics
- Vol. 32 (5) , 111-117
The accuracies of three intraoral scanners with regard to shade determination: An in vitro study
Purpose: To compare the accuracies of three intraoral scanners for shade determination function in vitro, and to preliminarily investigate the shade‐matching characteristics of the three intraoral scanners.Materials and Methods: The shade of the middle third region of each shade tab on the Vita Classical A1‐D4 shade guide (VC) was measured with a spectrophotometer (Vita Easyshade V, VE) and three intraoral scanners, including CEREC Omnicam (OM), 3Shape TRIOS 3 (T3), and TRIOS 4 (T4). A conversion table between VC values and CIELAB values was established from the database of VE to analyze the trueness. The reproducibility of the instruments was then compared by repeating the measurements five times.Results: The mean color difference for each instrument was highest in the OM, followed by the T4, and lowest in the T3 and VE, respectively. The L* and a* value for OM, and the b* value for T4, were significantly different from those for VE (p <0.05). The reproducibility of the instrument was highest in the VE (Fleiss’ kappa: 0.95), followed by the T3 (Fleiss’ kappa: 0.89), T4 (Fleiss’ kappa: 0.87), and OM (Fleiss’ kappa: 0.78).Conclusions: Of the three intraoral scanners, the trueness was best on the T3. The reproducibility of all the instruments was excellent.
- 10 August 2022
- Published by Wiley in Journal of Prosthodontics
- Vol. 32 (5) , 111-117
The accuracies of three intraoral scanners with regard to shade determination: An in vitro study
Purpose: To compare the accuracies of three intraoral scanners for shade determination function in vitro, and to preliminarily investigate the shade‐matching characteristics of the three intraoral scanners.Materials and Methods: The shade of the middle third region of each shade tab on the Vita Classical A1‐D4 shade guide (VC) was measured with a spectrophotometer (Vita Easyshade V, VE) and three intraoral scanners, including CEREC Omnicam (OM), 3Shape TRIOS 3 (T3), and TRIOS 4 (T4). A conversion table between VC values and CIELAB values was established from the database of VE to analyze the trueness. The reproducibility of the instruments was then compared by repeating the measurements five times.Results: The mean color difference for each instrument was highest in the OM, followed by the T4, and lowest in the T3 and VE, respectively. The L* and a* value for OM, and the b* value for T4, were significantly different from those for VE (p <0.05). The reproducibility of the instrument was highest in the VE (Fleiss’ kappa: 0.95), followed by the T3 (Fleiss’ kappa: 0.89), T4 (Fleiss’ kappa: 0.87), and OM (Fleiss’ kappa: 0.78).Conclusions: Of the three intraoral scanners, the trueness was best on the T3. The reproducibility of all the instruments was excellent.
- Open Access
- 28 April 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 146, 105564
Comparison of four CAD-CAM guides for preparing guiding planes of removable partial dentures
- 28 April 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 146, 105564
Open AccessComparison of four CAD-CAM guides for preparing guiding planes of removable partial dentures
- 19 April 2022
- Published by Emerald Publishing in Rapid Prototyping Journal
- Vol. 28 (9) , 1625-1635
Effects of selective laser melting process parameters on the accuracy of the intaglio surface of maxillary removable partial denture frameworks
Purpose: This in vitro study aims to explore the effects of selective laser melting (SLM) process parameters on the accuracy of the intaglio surface of cobalt–chromium alloy (Co–Cr), commercially pure titanium (CP Ti) and titanium alloy (Ti–6Al–4V) maxillary removable partial denture (RPD) frameworks and optimize these process parameters. Design/methodology/approach: Maxillary RPD framework specimens designed on a benchmark model were built. The process parameters, including contour scan speed and laser power, infill scan speed and laser power, hatch space, build orientation and metallic powder type, were arranged through the Taguchi design. Three-dimensional deviations of the clasps area, connector area and overall area of maxillary RPD frameworks were analyzed by using root mean square (RMS) as a metric. One-way analyses of variance with the above RMSs as the dependent variable were carried out (α = 0.05). Findings: Maxillary RPD frameworks built horizontally had a more accurate intaglio surface than those built at other orientation angles; CP Ti or Ti–6Al–4V maxillary RPD frameworks had a more accurate intaglio surface than Co–Cr ones; the Maxillary RPD framework built with a higher infill scan speed and lower infill laser power had the more accurate intaglio surface than the one built with other levels of these two process parameters. Originality/value: A novel benchmark model for evaluating the accuracy of the intaglio surface of maxillary RPD frameworks manufactured by SLM is proposed. The accuracy of the intaglio surface of maxillary RPD frameworks can be improved by adjusting SLM process parameters. The optimal setting of process parameters concerning the accuracy of the intaglio surface of maxillary RPD frameworks was given.
- 19 April 2022
- Published by Emerald Publishing in Rapid Prototyping Journal
- Vol. 28 (9) , 1625-1635
Effects of selective laser melting process parameters on the accuracy of the intaglio surface of maxillary removable partial denture frameworks
Purpose: This in vitro study aims to explore the effects of selective laser melting (SLM) process parameters on the accuracy of the intaglio surface of cobalt–chromium alloy (Co–Cr), commercially pure titanium (CP Ti) and titanium alloy (Ti–6Al–4V) maxillary removable partial denture (RPD) frameworks and optimize these process parameters. Design/methodology/approach: Maxillary RPD framework specimens designed on a benchmark model were built. The process parameters, including contour scan speed and laser power, infill scan speed and laser power, hatch space, build orientation and metallic powder type, were arranged through the Taguchi design. Three-dimensional deviations of the clasps area, connector area and overall area of maxillary RPD frameworks were analyzed by using root mean square (RMS) as a metric. One-way analyses of variance with the above RMSs as the dependent variable were carried out (α = 0.05). Findings: Maxillary RPD frameworks built horizontally had a more accurate intaglio surface than those built at other orientation angles; CP Ti or Ti–6Al–4V maxillary RPD frameworks had a more accurate intaglio surface than Co–Cr ones; the Maxillary RPD framework built with a higher infill scan speed and lower infill laser power had the more accurate intaglio surface than the one built with other levels of these two process parameters. Originality/value: A novel benchmark model for evaluating the accuracy of the intaglio surface of maxillary RPD frameworks manufactured by SLM is proposed. The accuracy of the intaglio surface of maxillary RPD frameworks can be improved by adjusting SLM process parameters. The optimal setting of process parameters concerning the accuracy of the intaglio surface of maxillary RPD frameworks was given.
- Open Access
- 1 January 2022
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 66 (3) , 445-451
Three-dimensional digital evaluation of thickness accuracy of mock-ups fabricated by silicone matrices: An in vitro study
Purpose: Although mock-ups have been widely used in dental esthetic rehabilitation, their accuracy has not been quantitatively evaluated, and the methods of fabricating mock-ups are various. This in vitro study investigated the thickness accuracy of mock-ups fabricated with different silicone matrices.Methods: Mock-ups of maxillary anterior teeth were respectively fabricated by 72 silicone matrices that were equally divided into four groups (n=18 for each group) according to two variables of the silicone matrices: labial margin position (equigingival or cover labial gingiva for 1−2 mm) and palatal notches (with or without notches on the palatal side of silicone matrices). The thickness accuracy of the mock-ups was analyzed using 3D scanning and 3D deviation analysis techniques compared with diagnostic waxing. The thickness change ratios of the mock-ups were compared using a two-way analysis of variance (ANOVA). One-way ANOVA and Kruskal-Wallis tests were used to compare differences in thickness change ratios between different teeth in each group.Results: The thickness accuracy of the mock-ups was significantly affected by the labial margin position and the palatal notches of the silicone matrices, respectively, in the labial area and the incisal area. The most accurate mock-ups were made using silicone matrices with equigingival labial margins and palatal notches. The thickness accuracy of the mock-ups was also inconsistent on different teeth.Conclusions: The mock-ups fabricated by silicone matrices were thicker than the diagnostic waxing. The application of silicone matrices to equigingival labial margins and palatal notches was beneficial to the thickness accuracy of mock-ups.
- 1 January 2022
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 66 (3) , 445-451
Open AccessThree-dimensional digital evaluation of thickness accuracy of mock-ups fabricated by silicone matrices: An in vitro study
Purpose: Although mock-ups have been widely used in dental esthetic rehabilitation, their accuracy has not been quantitatively evaluated, and the methods of fabricating mock-ups are various. This in vitro study investigated the thickness accuracy of mock-ups fabricated with different silicone matrices.Methods: Mock-ups of maxillary anterior teeth were respectively fabricated by 72 silicone matrices that were equally divided into four groups (n=18 for each group) according to two variables of the silicone matrices: labial margin position (equigingival or cover labial gingiva for 1−2 mm) and palatal notches (with or without notches on the palatal side of silicone matrices). The thickness accuracy of the mock-ups was analyzed using 3D scanning and 3D deviation analysis techniques compared with diagnostic waxing. The thickness change ratios of the mock-ups were compared using a two-way analysis of variance (ANOVA). One-way ANOVA and Kruskal-Wallis tests were used to compare differences in thickness change ratios between different teeth in each group.Results: The thickness accuracy of the mock-ups was significantly affected by the labial margin position and the palatal notches of the silicone matrices, respectively, in the labial area and the incisal area. The most accurate mock-ups were made using silicone matrices with equigingival labial margins and palatal notches. The thickness accuracy of the mock-ups was also inconsistent on different teeth.Conclusions: The mock-ups fabricated by silicone matrices were thicker than the diagnostic waxing. The application of silicone matrices to equigingival labial margins and palatal notches was beneficial to the thickness accuracy of mock-ups.
- Open Access
- 1 January 2021
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 13 (6) , 361-372
Evaluation of functional suitable digital complete denture system based on 3D printing technology
Deng K, et al. J Adv Prosthodont. 2021 Dec;13(6):361-372. https://doi.org/10.4047/jap.2021.13.6.361
- 1 January 2021
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 13 (6) , 361-372
Open AccessEvaluation of functional suitable digital complete denture system based on 3D printing technology
Deng K, et al. J Adv Prosthodont. 2021 Dec;13(6):361-372. https://doi.org/10.4047/jap.2021.13.6.361