Evaluation of UR-UVGI System for Sterilization Effect on Microorganism Contamination in Negative Pressure Isolation Ward
Open Access
- 6 September 2018
- journal article
- research article
- Published by MDPI AG in Sustainability
- Vol. 10 (9) , 3192
Abstract
A negative pressure isolation ward prevents the outflow of airborne microorganisms from inside the ward, minimizing the spread of airborne contamination causing respiratory infection. In response to recent outbreaks of severe acute respiratory syndrome (SARS) and Middle East respiratory syndrome (MERS), Korea has increased the number of these facilities. However, airborne contaminants that flow into the ward from adjacent areas may cause secondary harm to patients. In this study, the sterilization effect of upper-room ultraviolet germicidal irradiation (UR-UVGI) on microorganisms generated within the negative pressure isolation ward and those flowing inward from adjacent areas was evaluated through field experiments and computational fluid dynamics (CFD) analysis, to assess the potential of this approach as a supplementary measure to control such microorganisms. The sterilization effect was found to be not high because of high-level ventilation. CFD analysis under various conditions shows that the sterilization effect for indoor-generated microorganisms varies with the level of UV radiation, the source locations of the indoor-generated microorganisms, air supplies and exhausts, the UVGI system, and the airflow formed under the specified conditions. Our results show that when the UVGI system is installed in the upper part of the ward entrance, contaminated air from adjacent area is strongly sterilized.Keywords
Funding Information
- National Research Foundation of Korea (NRF-2017R1D1A1B03033016)
This publication has 21 references indexed in Scilit:
- Using Computational Fluid Dynamics Modeling to Evaluate the Design of Hospital Ultraviolet Germicidal Irradiation Systems for Inactivating Airborne Mycobacteria†Photochemistry and Photobiology, 2013
- Ultraviolet Germicidal Irradiation Safety Concerns: A Lesson from the Tuberculosis Ultraviolet Shelter Study Murphy's Law AffirmedPhotochemistry and Photobiology, 2012
- Application of CFD Simulation to Predicting Upper‐Room UVGI EffectivenessPhotochemistry and Photobiology, 2012
- Applications of ultraviolet germicidal irradiation disinfection in health care facilities: Effective adjunct, but not stand-alone technologyAmerican Journal of Infection Control, 2010
- Distribution of Airborne Influenza Virus and Respiratory Syncytial Virus in an Urgent Care Medical ClinicClinical Infectious Diseases, 2010
- 2007 Guideline for Isolation Precautions: Preventing Transmission of Infectious Agents in Health Care SettingsAmerican Journal of Infection Control, 2007
- Use of CFD Modelling to Optimise the Design of Upper-room UVGI Disinfection Systems for Ventilated RoomsIndoor and Built Environment, 2006
- Development of a numerical model to simulate the biological inactivation of airborne microorganisms in the presence of ultraviolet lightJournal of Aerosol Science, 2004
- Efficacy of ultraviolet germicidal irradiation of upper-room air in inactivating airborne bacterial spores and mycobacteria in full-scale studiesAtmospheric Environment, 2003
- Effect of Ultraviolet Germicidal Lamps on Airborne Microorganisms in an Outpatient Waiting RoomApplied Occupational and Environmental Hygiene, 1992