On-line image guidance for frameless stereotactic radiotherapy of lung malignancies by cone beam CT: Comparison between target localization and alignment on bony anatomy
Authors:
Open Access
- 1 January 2008
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 47 (7) , 1422-1431
Abstract
Introduction. Free-breathing stereotactic radiotherapy for lung malignancies requires reliable prediction of respiratory motion and accurate target localization. A protocol was adopted for reproducibility and reduction of respiratory motion and for target localization by CBCT image guidance. Tumor respiratory displacements and tumor positioning errors relative to bony anatomy alignment are analyzed. Materials and method. Image guided SRT was performed for 99 lung malignancies. Two groups of patients were considered: group A did not perform any breathing control; group B controlled visually their respiratory cycle and volumes on an Active Breathing Coordinator (ABC) monitor during the acquisition of simulation CT and CBCT, and treatment delivery. GTV on end inhale and exhale CT data sets were fused in an ITV and the extent of tumor motion evaluated between these 2 phases. A pre-treatment CBCT was acquired and aligned to the reference CT using bony anatomy; for tumor positioning the ITV contour on the reference CT was matched to the visible tumor on CBCT. Interobserver variability of tumor positioning was evaluated. ITV and CBCT tumor dimensions were compared. Results. 3D tumor breathing displacement (mean±SD) was significantly higher for group A (14.7±9.9 mm) than for group B (4.7±3.1 mm). The detected differences between tumor and bony structure alignment below 3 mm were 68% for group B and 45% for group A, reaching statistical significance. Interobserver variability was 1.7±1.1 mm (mean±SD). Dimensions of tumor image on CBCT were consistent with ITV dimensions for group B (max difference 14%). Conclusions. The adopted protocol seems effective in reducing respiratory internal movements and margin. Tumor positioning errors relative to bony anatomy are also reduced. However bony anatomy as a surrogate of the target may still lead to some relevant positioning errors. Target visualization on CBCT is essential for an accurate localization in lung SRT.Keywords
This publication has 16 references indexed in Scilit:
- Relevance of Biologically Equivalent Dose Values in Outcome Evaluation of Stereotactic Radiotherapy for Lung NodulesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- Cone-Beam CT Localization of Internal Target Volumes for Stereotactic Body Radiotherapy of Lung LesionsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Kilo-Voltage Cone-Beam Computed Tomography Setup Measurements for Lung Cancer Patients; First Clinical Results and Comparison With Electronic Portal-Imaging DeviceInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Active breathing control (ABC): Determination and reduction of breathing-induced organ motion in the chestInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Benefit of three-dimensional image-guided stereotactic localization in the hypofractionated treatment of lung cancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumorsActa Oncologica, 2006
- Respiration correlated cone-beam computed tomography and 4DCT for evaluating target motion in Stereotactic Lung Radiation TherapyActa Oncologica, 2006
- Internal movement, set-up accuracy and margins for stereotactic body radiotherapy using a stereotactic body frameActa Oncologica, 2006
- Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatmentSeminars in Radiation Oncology, 2004
- Stereotactic Radiotherapy of Malignancies in the Abdomen: Methodological aspectsActa Oncologica, 1994