A Comparison between superb microvascular imaging technique and conventional doppler ultrasound in evaluating chronic allograft damage in renal transplant recipients
Open Access
- 12 January 2023
- journal article
- research article
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 29 (2) , 212-218
Abstract
The present study comparatively evaluates the performance of conventional Doppler ultrasound and superb microvascular imaging (SMI) in delineating the cortical microvessels of the transplanted kidney and compares the chronic allograft damage index (CADI) based on the examination of biopsy specimens with Doppler ultrasound and SMI findings. Sixty-eight renal transplant recipients underwent kidney biopsy with the pre-diagnosis of rejection before undergoing renal Doppler ultrasound examination between January 2020 and October 2020. The distance between the kidney capsule and the vascular structure closest to the kidney capsule was measured at the level of the lower pole in the transplanted kidney using color Doppler ultrasound (CDUS), power Doppler ultrasound (PDUS), and the SMI technique. The kidney size, resistive index at the level of the arcuate artery in the lower pole of the kidney, and renal artery flow rates were also measured. The mean distance between the kidney capsule and the vessel was 2.44 ± 2.0 mm on CDUS, 1.34 ± 1.2 mm on PDUS, 0.99 ± 1.8 mm using the color SMI (cSMI) technique, and 0.86 ± 1.8 mm using the monochrome SMI (mSMI) technique. The study found that the SMI technique was superior to CDUS and PDUS in delineating the cortical microvasculature of the kidney. Both Doppler ultrasound examinations and the SMI technique proved effective in predicting the CADI (P = 0.006 for CDUS, P = 0.002 for PDUS, P = 0.018 for cSMI, and P = 0.027 for mSMI). Among conventional Doppler ultrasound examinations and the SMI technique, PDUS had the highest sensitivity, and cSMI had the highest specificity in differentiating high and low CADI values. Both the cSMI and mSMI techniques had similar sensitivity values, whereas only cSMI exhibited high specificity. CDUS had the lowest specificity value (P = 0.003 for CDUS, P = 0.002 for PDUS, P = 0.005 for cSMI, and P = 0.004 for mSMI). The present study is the first in the literature to demonstrate the utility of the distance between the kidney capsule and the vessels in predicting the CADI score and to compare the Doppler ultrasound examinations and SMI technique in doing so.Keywords
This publication has 26 references indexed in Scilit:
- Green Tagging in Displaying Color Doppler Aliasing: A Comparison to Standard Color Mapping in Renal Artery StenosisUltrasound in Medicine & Biology, 2013
- Renal Vascular Perfusion Index in a Canine ModelUltrasound in Medicine & Biology, 2009
- Evaluation of Cortical Perfusion in Renal Transplants: Application of Quantified Power Doppler UltrasonographyTransplantation Proceedings, 2008
- Histologic and Clinical Findings in Living Donor Allografts with Long-Term Stable FunctionAmerican Journal of Nephrology, 2006
- Real-Time Contrast-Enhanced Sonography of Renal Transplant Recipients Predicts Chronic Allograft NephropathyAmerican Journal of Transplantation, 2006
- Correlation Between the Resistive Index by Doppler Ultrasound and Kidney Function and HistologyAmerican Journal of Kidney Diseases, 2005
- Protocol core needle biopsy and histological chronic allograft damage index as surrogate endpoint for Long-Term graft survivalTransplantation Proceedings, 2004
- PERCUTANEOUS NEEDLE BIOPSY OF THE RENAL ALLOGRAFTTransplantation, 1990
- Intrarenal arterial Doppler sonography in patients with nonobstructive renal disease: correlation of resistive index with biopsy findings.American Journal of Roentgenology, 1990
- Duplex Doppler US of renal allografts: causes of elevated resistive index.Radiology, 1989