Kağan Çeken
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kağan Çeken has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Ayşe Keven
Akdeniz University School of Medicine, Akdeniz University
3 shared publications - Adnan Kabaalioğlu
Department of Radiology, Koç University School of Medicine, Istanbul, Turkey
2 shared publications - Ahmet Faruk Gürbüz
Akdeniz University School of Medicine, Akdeniz University
2 shared publications - Havva Serap Toru
Department of Pathology, Akdeniz University, School of Medicine, Antalya, Turkey
2 shared publications - Ali Apaydin
Department of Radiology, Akdeniz University Faculty of Medicine, Antalya, Turkey
1 shared publication Ali Apaydın
Medical Faculty, Department of Radiology, Akdeniz University, Dumlupınar bulvarı, Akdeniz Üniversitesi Hastanesi, Arapsuyu, 07059, Antalya, Turkey
1 shared publication
Latest Publications
- 13 July 2026
- Published by Springer Nature in Journal of Ultrasound
- Vol. 29 (3) , 617-627
Noninvasive assessment of chronic rejection in kidney transplant recipients with linear probe shear wave elastography
To compare linear and convex probe shear wave elastography (SWE) for the diagnosis of chronic rejection in renal transplant recipients. In this prospective study, 84 patients (42 with stable and 42 with unstable graft function) underwent SWE examinations using linear and convex probes. Elasticity values, resistive index (RI), and laboratory parameters (creatinine, eGFR, and proteinuria) were analyzed. Chronic rejection was confirmed by biopsy in patients with unstable graft function. Linear probe SWE values were significantly higher in patients with rejection than in those without rejection (15.91 vs. 12.3 kPa, p < 0.05). A cutoff value of 15.45 kPa predicted rejection with 66.7% sensitivity and 80% specificity (AUC: 0.76). Convex probe SWE showed no diagnostic utility. Linear SWE values correlated with elevated creatinine levels (p < 0.05), increased proteinuria (p < 0.05), and reduced eGFR (r = -0.436). RI values were not predictive. Linear probe SWE provides superior performance compared with convex probe SWE in detecting chronic rejection, representing a potential noninvasive tool to support biopsy decisions and monitor fibrosis.
- 13 July 2026
- Published by Springer Nature in Journal of Ultrasound
- Vol. 29 (3) , 617-627
Noninvasive assessment of chronic rejection in kidney transplant recipients with linear probe shear wave elastography
To compare linear and convex probe shear wave elastography (SWE) for the diagnosis of chronic rejection in renal transplant recipients. In this prospective study, 84 patients (42 with stable and 42 with unstable graft function) underwent SWE examinations using linear and convex probes. Elasticity values, resistive index (RI), and laboratory parameters (creatinine, eGFR, and proteinuria) were analyzed. Chronic rejection was confirmed by biopsy in patients with unstable graft function. Linear probe SWE values were significantly higher in patients with rejection than in those without rejection (15.91 vs. 12.3 kPa, p < 0.05). A cutoff value of 15.45 kPa predicted rejection with 66.7% sensitivity and 80% specificity (AUC: 0.76). Convex probe SWE showed no diagnostic utility. Linear SWE values correlated with elevated creatinine levels (p < 0.05), increased proteinuria (p < 0.05), and reduced eGFR (r = -0.436). RI values were not predictive. Linear probe SWE provides superior performance compared with convex probe SWE in detecting chronic rejection, representing a potential noninvasive tool to support biopsy decisions and monitor fibrosis.
- Open Access
- 12 January 2023
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 29 (2) , 212-218
A Comparison between superb microvascular imaging technique and conventional doppler ultrasound in evaluating chronic allograft damage in renal transplant recipients
The present study comparatively evaluates the performance of conventional Doppler ultrasound and superb microvascular imaging (SMI) in delineating the cortical microvessels of the transplanted kidney and compares the chronic allograft damage index (CADI) based on the examination of biopsy specimens with Doppler ultrasound and SMI findings. Sixty-eight renal transplant recipients underwent kidney biopsy with the pre-diagnosis of rejection before undergoing renal Doppler ultrasound examination between January 2020 and October 2020. The distance between the kidney capsule and the vascular structure closest to the kidney capsule was measured at the level of the lower pole in the transplanted kidney using color Doppler ultrasound (CDUS), power Doppler ultrasound (PDUS), and the SMI technique. The kidney size, resistive index at the level of the arcuate artery in the lower pole of the kidney, and renal artery flow rates were also measured. The mean distance between the kidney capsule and the vessel was 2.44 ± 2.0 mm on CDUS, 1.34 ± 1.2 mm on PDUS, 0.99 ± 1.8 mm using the color SMI (cSMI) technique, and 0.86 ± 1.8 mm using the monochrome SMI (mSMI) technique. The study found that the SMI technique was superior to CDUS and PDUS in delineating the cortical microvasculature of the kidney. Both Doppler ultrasound examinations and the SMI technique proved effective in predicting the CADI (P = 0.006 for CDUS, P = 0.002 for PDUS, P = 0.018 for cSMI, and P = 0.027 for mSMI). Among conventional Doppler ultrasound examinations and the SMI technique, PDUS had the highest sensitivity, and cSMI had the highest specificity in differentiating high and low CADI values. Both the cSMI and mSMI techniques had similar sensitivity values, whereas only cSMI exhibited high specificity. CDUS had the lowest specificity value (P = 0.003 for CDUS, P = 0.002 for PDUS, P = 0.005 for cSMI, and P = 0.004 for mSMI). The present study is the first in the literature to demonstrate the utility of the distance between the kidney capsule and the vessels in predicting the CADI score and to compare the Doppler ultrasound examinations and SMI technique in doing so.
- 12 January 2023
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 29 (2) , 212-218
Open AccessA Comparison between superb microvascular imaging technique and conventional doppler ultrasound in evaluating chronic allograft damage in renal transplant recipients
The present study comparatively evaluates the performance of conventional Doppler ultrasound and superb microvascular imaging (SMI) in delineating the cortical microvessels of the transplanted kidney and compares the chronic allograft damage index (CADI) based on the examination of biopsy specimens with Doppler ultrasound and SMI findings. Sixty-eight renal transplant recipients underwent kidney biopsy with the pre-diagnosis of rejection before undergoing renal Doppler ultrasound examination between January 2020 and October 2020. The distance between the kidney capsule and the vascular structure closest to the kidney capsule was measured at the level of the lower pole in the transplanted kidney using color Doppler ultrasound (CDUS), power Doppler ultrasound (PDUS), and the SMI technique. The kidney size, resistive index at the level of the arcuate artery in the lower pole of the kidney, and renal artery flow rates were also measured. The mean distance between the kidney capsule and the vessel was 2.44 ± 2.0 mm on CDUS, 1.34 ± 1.2 mm on PDUS, 0.99 ± 1.8 mm using the color SMI (cSMI) technique, and 0.86 ± 1.8 mm using the monochrome SMI (mSMI) technique. The study found that the SMI technique was superior to CDUS and PDUS in delineating the cortical microvasculature of the kidney. Both Doppler ultrasound examinations and the SMI technique proved effective in predicting the CADI (P = 0.006 for CDUS, P = 0.002 for PDUS, P = 0.018 for cSMI, and P = 0.027 for mSMI). Among conventional Doppler ultrasound examinations and the SMI technique, PDUS had the highest sensitivity, and cSMI had the highest specificity in differentiating high and low CADI values. Both the cSMI and mSMI techniques had similar sensitivity values, whereas only cSMI exhibited high specificity. CDUS had the lowest specificity value (P = 0.003 for CDUS, P = 0.002 for PDUS, P = 0.005 for cSMI, and P = 0.004 for mSMI). The present study is the first in the literature to demonstrate the utility of the distance between the kidney capsule and the vessels in predicting the CADI score and to compare the Doppler ultrasound examinations and SMI technique in doing so.
- 18 February 2021
- Published by SRUMB - Romanian Society for Ultrasonography in Medicine and Biology in Medical Ultrasonography
- Vol. 23 (1) , 89-93
Imaging appearance of post umbilical venous catheter displacement: liver collections in children
Umbilical venous catheters (UVCs) have become a part of routine perinatal care. In the case of its misplacement, extravasation into liver parenchyma might be observed and unusual findings might be detected and a suspicion of tumoral lesions emerges during the ultrasound examination. To avoid the unnecessary liver biopsies and catastrophic complications of UVC misplacement in the pediatric population, clinicians and radiologists must be familiar with the radiological findings. We aimed to present sonographic and computed tomographic images of liver collections resulting from UVC malposition
- 18 February 2021
- Published by SRUMB - Romanian Society for Ultrasonography in Medicine and Biology in Medical Ultrasonography
- Vol. 23 (1) , 89-93
Imaging appearance of post umbilical venous catheter displacement: liver collections in children
Umbilical venous catheters (UVCs) have become a part of routine perinatal care. In the case of its misplacement, extravasation into liver parenchyma might be observed and unusual findings might be detected and a suspicion of tumoral lesions emerges during the ultrasound examination. To avoid the unnecessary liver biopsies and catastrophic complications of UVC misplacement in the pediatric population, clinicians and radiologists must be familiar with the radiological findings. We aimed to present sonographic and computed tomographic images of liver collections resulting from UVC malposition
- 14 September 2005
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 26 (S 1) , P102
UMBILICAL CORD PSEUDOCYST IN A FETUS WITH TRISOMY 21
Purpose: Umbilical cord cysts are often categorized as true cysts or pseudocysts. Pseudocysts tend to be located close to the fetal insertion of the cord. These cysts can be found in the first trimester, if they insist on occurring in the second trimester, they are strongly associated with chromosomal disorders and structural defects, especially with Trisomy 18 in which other abnormalities are often detected in the ultrasonography. However, these cystic masses have attracted little attention in trisomy 21, especially when they are isolated. We aim to present the isolated umbilical pseudocyst in trisomy 21. Methods and Materials: A cystic mass in the umbilical cord was found by sonography in a 19-year-old patient in 28th week of her first pregnancy. Results: In the gray scale images, it was located near the fetal insertion of the cord and lying through abdominal wall. Color Doppler imaging revealed that there was no blood stream in the cyst which encircled the three umbilical vessels. Although we could not find any additional findings of chromosomal abnormalities except for pseudocyst in the detailed fetal ultrasonographic examination, we decided to do amniocentesis. Karyotyping confirmed the diagnosis of trisomy 21. Conclusions: In our case, isolated umbilical pseudocyst led us to the karyotype analysis. If the umbilical cord cysts are detected in the second trimester of pregnancy, we recommend detailed sonographic examination and amniocentesis.
- 14 September 2005
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 26 (S 1) , P102
UMBILICAL CORD PSEUDOCYST IN A FETUS WITH TRISOMY 21
Purpose: Umbilical cord cysts are often categorized as true cysts or pseudocysts. Pseudocysts tend to be located close to the fetal insertion of the cord. These cysts can be found in the first trimester, if they insist on occurring in the second trimester, they are strongly associated with chromosomal disorders and structural defects, especially with Trisomy 18 in which other abnormalities are often detected in the ultrasonography. However, these cystic masses have attracted little attention in trisomy 21, especially when they are isolated. We aim to present the isolated umbilical pseudocyst in trisomy 21. Methods and Materials: A cystic mass in the umbilical cord was found by sonography in a 19-year-old patient in 28th week of her first pregnancy. Results: In the gray scale images, it was located near the fetal insertion of the cord and lying through abdominal wall. Color Doppler imaging revealed that there was no blood stream in the cyst which encircled the three umbilical vessels. Although we could not find any additional findings of chromosomal abnormalities except for pseudocyst in the detailed fetal ultrasonographic examination, we decided to do amniocentesis. Karyotyping confirmed the diagnosis of trisomy 21. Conclusions: In our case, isolated umbilical pseudocyst led us to the karyotype analysis. If the umbilical cord cysts are detected in the second trimester of pregnancy, we recommend detailed sonographic examination and amniocentesis.