Combined AM and PM signal analysis with applications to the dynamic testing of phasor measurement units
Authors:
- 1 August 2014
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 682-683
Abstract
Phasor measurement units (PMU) need to satisfy dynamic performance requirements. One of such requirements is phasor, frequency and rate of change of frequency measurements with a specified level of combined amplitude and phase modulation of the power signals. A simple method for estimating parameters of such modulated signals from digital sampling data is presented. Prior information available to metrologists about the signal components allows the reduction of the dimensionality of the search algorithm with consequent time savings.Keywords
This publication has 6 references indexed in Scilit:
- Calibration of Phasor Measurement Unit at NISTIEEE Transactions on Instrumentation and Measurement, 2013
- Calculating combined amplitude and phase modulated power signal parameters2011
- A Simple Algorithm for Bayesian Signal Analysis With Applications to MetrologyIEEE Transactions on Instrumentation and Measurement, 2011
- Reference Values for Dynamic Calibration of PMUs2008
- Precision Measurement of Power Harmonics and FlickerIEEE Transactions on Instrumentation and Measurement, 2005
- A new scheme for generating and measuring active, reactive, and apparent power at power frequencies with uncertainties of 2.5×10/sup -6/IEEE Transactions on Instrumentation and Measurement, 1999