Abstract
In this study, drift of microelectromechanical system (MEMS) accelerometers stored at room temperature for one year is investigated by both finite element analysis (FEA) simulation and experiments. In the simulation, a comprehensive FEA model considering the die-attach adhesive viscoelasticity was established to emulate the deformation of the sensor package structure during storage. Then drift models of scale factor and bias of the accelerometer were built according to the deformed structure. To validate the simulation results, several accelerometers were packaged and their outputs were tested and recorded once per month. The two parameters displayed a continuous drift owing to the release of the packaging stress in the chip. The scale factor drifts were negative and about 2500 ppm for different types of the sensors. However, the bias drifts were positive or negative, and their magnitudes were ranging from 12 mg to 32 mg in storage. Moreover, they reached a steady state after about 10 months (<50 ppm per month for scale factor) and 6 months (<1 mg per month for bias) room temperature storage. The results in this paper provide meaningful guidance for the application of MEMS accelerometers.
Funding Information
  • Natural Science Foundation of Sichuan Province of China (2022NSFSC2013)
  • Chunhui Project Foundation of the Education Department of China (182559)
  • Sichuan Science and Technology Support Project (2020YFQ0017)
  • National Natural Science Foundation of China (52075082)

This publication has 46 references indexed in Scilit: