Fractional-slot distributed windings can be used to reduce the amplitude of the critical sideband with 12·f1 and the resultant mode 0, related to the slot harmonics of integral-slot windings when considering the acoustic noise and vibration of synchronous machines. Due to the design complexity, the single-layer fractional-slot distributed windings have not been comprehensively analyzed yet. Therefore, this article analyzes comparable highly utilized electrically excited synchronous machines equipped with single- and double-layer fractional-slot distributed windings, considering the experimental results of performance, acoustic noise, and electromagnetic-based vibration. The rotating field theory and winding analysis are applied to explain the presence of dominant sidebands of the measured electromagnetic-based vibration.