Seyed Morteza Raziee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Seyed Morteza Raziee has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Bernd Ponick
Institute for Drive Systems and Power Electronics, Leibniz Universität Hannover, Hanover, Germany
4 shared publications- Bernd Ponick
Institute for Drive Systems and Power Electronics (IAL), Leibniz University Hannover, Hannover, Germany
4 shared publications Onur Misir
Institute for Drive Systems and Power Electronics, Leibniz Universität Hannover, Hanover, Germany
4 shared publications- Jörn Steinbrink
Institute for Drive Systems and Power Electronics, Leibniz University Hannover, Hannover, Germany
2 shared publications - Onur Misir
Volkswagen AG, 38440 Wolfsburg, Germany
2 shared publications A. Omati
1 shared publication
Latest Publications
- 21 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-11
Performance and NVH Analysis of Comparable Synchronous Machines With Single- and Double-Layer Fractional-Slot Distributed Windings
Fractional-slot distributed windings can be used to reduce the amplitude of the critical sideband with 12·f1 and the resultant mode 0, related to the slot harmonics of integral-slot windings when considering the acoustic noise and vibration of synchronous machines. Due to the design complexity, the single-layer fractional-slot distributed windings have not been comprehensively analyzed yet. Therefore, this article analyzes comparable highly utilized electrically excited synchronous machines equipped with single- and double-layer fractional-slot distributed windings, considering the experimental results of performance, acoustic noise, and electromagnetic-based vibration. The rotating field theory and winding analysis are applied to explain the presence of dominant sidebands of the measured electromagnetic-based vibration.
- 21 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-11
Performance and NVH Analysis of Comparable Synchronous Machines With Single- and Double-Layer Fractional-Slot Distributed Windings
Fractional-slot distributed windings can be used to reduce the amplitude of the critical sideband with 12·f1 and the resultant mode 0, related to the slot harmonics of integral-slot windings when considering the acoustic noise and vibration of synchronous machines. Due to the design complexity, the single-layer fractional-slot distributed windings have not been comprehensively analyzed yet. Therefore, this article analyzes comparable highly utilized electrically excited synchronous machines equipped with single- and double-layer fractional-slot distributed windings, considering the experimental results of performance, acoustic noise, and electromagnetic-based vibration. The rotating field theory and winding analysis are applied to explain the presence of dominant sidebands of the measured electromagnetic-based vibration.
- 12 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 39 (2) , 988-998
Winding Factor Equation for Main Pattern of Single-Layer Fractional-Slot Distributed Windings
The winding factor is important to compare windings, to estimate the performance of electrical machines and to find the origin of electromagnetic NVH excitations analytically. Besides the available calculation methods, it is applicable to find calculation equations valid for the winding factor of all spatial harmonics in the case of symmetrical windings. There are such calculation equations for integral-slot and double-layer fractional-slot windings. However, there is no valid equation for single-layer fractional-slot distributed windings. This article reviews the already suggested equations in literature in a coherent notation and then derives a new one for the most applicable single-layer fractional-slot distributed windings.
- 12 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 39 (2) , 988-998
Winding Factor Equation for Main Pattern of Single-Layer Fractional-Slot Distributed Windings
The winding factor is important to compare windings, to estimate the performance of electrical machines and to find the origin of electromagnetic NVH excitations analytically. Besides the available calculation methods, it is applicable to find calculation equations valid for the winding factor of all spatial harmonics in the case of symmetrical windings. There are such calculation equations for integral-slot and double-layer fractional-slot windings. However, there is no valid equation for single-layer fractional-slot distributed windings. This article reviews the already suggested equations in literature in a coherent notation and then derives a new one for the most applicable single-layer fractional-slot distributed windings.
- 10 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 39 (1) , 504-515
Design of Single-Layer Fractional-Slot Distributed Windings
Besides the usual winding design method based on the star of slots , the winding index is proposed in this article. In compliance with the presented counterexamples, it can be shown that the star of slots is unable to design most of single-layer fractional-slot distributed windings. In some restricted cases, it is possible to apply the introduced additional step to extract the winding layout from the double-layer fractional-slot distributed winding for the same number of phases, number of slots and number of pole pairs. Generally, the winding index can be applied to design symmetrical windings such as single-layer fractional-slot distributed windings and windings with a variable zone width. However, a systematic design procedure based on the winding index has not yet been suggested in literature, which is the focus of this article.
- 10 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 39 (1) , 504-515
Design of Single-Layer Fractional-Slot Distributed Windings
Besides the usual winding design method based on the star of slots , the winding index is proposed in this article. In compliance with the presented counterexamples, it can be shown that the star of slots is unable to design most of single-layer fractional-slot distributed windings. In some restricted cases, it is possible to apply the introduced additional step to extract the winding layout from the double-layer fractional-slot distributed winding for the same number of phases, number of slots and number of pole pairs. Generally, the winding index can be applied to design symmetrical windings such as single-layer fractional-slot distributed windings and windings with a variable zone width. However, a systematic design procedure based on the winding index has not yet been suggested in literature, which is the focus of this article.
- 13 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (10) , 7468-7479
Multiple Multiphase Combined Star–Polygon Winding Analysis
In order to improve the efficiency and to reduce the field amplitudes of spatial harmonics influencing noise and vibration of electrical machines, three- and five-phase combined star-polygon windings have been suggested in the literature. Besides, the efficiency of an electrical machine is dependent on the fundamental winding factor and the noise/vibration level is related to the winding factors of some higher/lower harmonics. However, there is no systematic method to calculate the winding factor of each spatial harmonic for a multiple topology. This paper deals with proposing different topologies of multiple series multiphase combined star-polygon windings and accordingly with the calculation methods of winding factors for all spatial harmonics and the harmonic leakage factor. The results of winding function approach and symmetrical components of electromotive forces (EMFs) are perfectly in compliance with each other, provided that the fast Fourier transform (FFT) analysis is sufficiently accurate. The results obtained from measurements on an unskewed electrically excited synchronous machine are applied for validating the results given by the sum of EMFs and the proposed calculation formula. The sum of EMFs, considering just one set of a multiple topology, can give the same results as the proposed winding analysis methods for the fundamental or the slot harmonic winding factors.
- 13 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (10) , 7468-7479
Multiple Multiphase Combined Star–Polygon Winding Analysis
In order to improve the efficiency and to reduce the field amplitudes of spatial harmonics influencing noise and vibration of electrical machines, three- and five-phase combined star-polygon windings have been suggested in the literature. Besides, the efficiency of an electrical machine is dependent on the fundamental winding factor and the noise/vibration level is related to the winding factors of some higher/lower harmonics. However, there is no systematic method to calculate the winding factor of each spatial harmonic for a multiple topology. This paper deals with proposing different topologies of multiple series multiphase combined star-polygon windings and accordingly with the calculation methods of winding factors for all spatial harmonics and the harmonic leakage factor. The results of winding function approach and symmetrical components of electromotive forces (EMFs) are perfectly in compliance with each other, provided that the fast Fourier transform (FFT) analysis is sufficiently accurate. The results obtained from measurements on an unskewed electrically excited synchronous machine are applied for validating the results given by the sum of EMFs and the proposed calculation formula. The sum of EMFs, considering just one set of a multiple topology, can give the same results as the proposed winding analysis methods for the fundamental or the slot harmonic winding factors.
- 28 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 54 (5) , 4315-4323
Performance Analysis of Synchronous Machines After Disconnecting Stator Coils
This paper offers methods to analyze the performance of three-phase synchronous machines operating with an unsymmetrical stator winding caused by cutting out and bypassing coils. The resulting unsymmetrical current distribution in the stator winding tends to produce overheating in parts of the stator and damper windings at full load as well as torque pulsations. Thus, the main objective of this study is to determine the maximal load, under which the unsymmetrical machine may operate without exceeding the permissible temperature limit. Based on the multi-loop method, a mathematical model of a synchronous machine with missing coils in the stator winding is developed. In order to determine the current distribution, the machines' system of differential equations is solved by using a numerical integration method (Runge-Kutta method). As an alternative method, the system of differential equations in the steady state is reduced to a system of algebraic equations, which can be solved with the Gaussian elimination method. Both methods are validated by the measurement results of a 25-kW salient pole synchronous machine. Furthermore, both the circulating current within the parallel branches and the line currents of the different phases as a result of coil or coil group cut-outs are analyzed for a large 41-MW cylindrical-rotor synchronous motor.
- 28 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 54 (5) , 4315-4323
Performance Analysis of Synchronous Machines After Disconnecting Stator Coils
This paper offers methods to analyze the performance of three-phase synchronous machines operating with an unsymmetrical stator winding caused by cutting out and bypassing coils. The resulting unsymmetrical current distribution in the stator winding tends to produce overheating in parts of the stator and damper windings at full load as well as torque pulsations. Thus, the main objective of this study is to determine the maximal load, under which the unsymmetrical machine may operate without exceeding the permissible temperature limit. Based on the multi-loop method, a mathematical model of a synchronous machine with missing coils in the stator winding is developed. In order to determine the current distribution, the machines' system of differential equations is solved by using a numerical integration method (Runge-Kutta method). As an alternative method, the system of differential equations in the steady state is reduced to a system of algebraic equations, which can be solved with the Gaussian elimination method. Both methods are validated by the measurement results of a 25-kW salient pole synchronous machine. Furthermore, both the circulating current within the parallel branches and the line currents of the different phases as a result of coil or coil group cut-outs are analyzed for a large 41-MW cylindrical-rotor synchronous motor.
- 21 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 33 (1) , 383-394
Combined Star-Delta Winding Analysis
The combined star-delta winding has been attracting the attention of industry because of its potential to improve the efficiency of electrical machines. In order to show the efficiency benefits of this type of winding, many authors have used methods to determine the improvements in winding factors, published in different papers, which have not been validated yet. Some of these methods contradict each other. Furthermore, as a demerit of this winding, a unidirectional rotation has been reported. In this paper, a set of new formulas to calculate the winding factors for combined star-delta windings is proposed. In order to check the validity of the proposed formulas, a 2-D FEM and experimental tests on a salient pole synchronous machine are presented, which allows different combined star-delta winding connections. In contrast to other publications, the measurements show that combined windings can be applied for both directions of rotation without any problems.
- 21 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 33 (1) , 383-394
Combined Star-Delta Winding Analysis
The combined star-delta winding has been attracting the attention of industry because of its potential to improve the efficiency of electrical machines. In order to show the efficiency benefits of this type of winding, many authors have used methods to determine the improvements in winding factors, published in different papers, which have not been validated yet. Some of these methods contradict each other. Furthermore, as a demerit of this winding, a unidirectional rotation has been reported. In this paper, a set of new formulas to calculate the winding factors for combined star-delta windings is proposed. In order to check the validity of the proposed formulas, a 2-D FEM and experimental tests on a salient pole synchronous machine are presented, which allows different combined star-delta winding connections. In contrast to other publications, the measurements show that combined windings can be applied for both directions of rotation without any problems.
- 6 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 53 (10) , 1-9
Winding Function Approach for Winding Analysis
The winding factor is an operand in order to consider the effect of winding distribution and chording on the spatial distribution of the magnetic field in the air gap of synchronous and induction machines. The sinusoidal functions for winding factor calculation presented in literature are not defined and valid for every irregular winding, e.g., single-layer fractional-slot, combined star-delta, multilayer (greater than two), and asymmetrical windings. Although the summation of induced voltage phasors (star of slots) is the most accurate method, asymmetrical windings require to be decomposed in symmetrical components. In this paper, in addition to deriving the symmetrical components for asymmetrical multiphase windings, the analytical formulation is presented to relate the harmonic content of winding functions to winding factors. The harmonic leakage factor is accurately formulated from the winding function instead of the Görges diagram without the need for summing up an infinite number of normalized winding factors quadratically. Without restriction of the number of layers and the distribution of the winding, including full-pitch, chorded and fractional-slot symmetrical and asymmetrical windings, the suggested analysis method is validated with the star of slots and sinusoidal functions of distribution and pitch factors, where applicable.
- 6 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 53 (10) , 1-9
Winding Function Approach for Winding Analysis
The winding factor is an operand in order to consider the effect of winding distribution and chording on the spatial distribution of the magnetic field in the air gap of synchronous and induction machines. The sinusoidal functions for winding factor calculation presented in literature are not defined and valid for every irregular winding, e.g., single-layer fractional-slot, combined star-delta, multilayer (greater than two), and asymmetrical windings. Although the summation of induced voltage phasors (star of slots) is the most accurate method, asymmetrical windings require to be decomposed in symmetrical components. In this paper, in addition to deriving the symmetrical components for asymmetrical multiphase windings, the analytical formulation is presented to relate the harmonic content of winding functions to winding factors. The harmonic leakage factor is accurately formulated from the winding function instead of the Görges diagram without the need for summing up an infinite number of normalized winding factors quadratically. Without restriction of the number of layers and the distribution of the winding, including full-pitch, chorded and fractional-slot symmetrical and asymmetrical windings, the suggested analysis method is validated with the star of slots and sinusoidal functions of distribution and pitch factors, where applicable.
- 12 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 53 (4) , 3579-3587
Prediction of Losses and Efficiency for Three-Phase Induction Machines Equipped With Combined Star–Delta Windings
Combined star–delta windings in electrical machines result in a higher fundamental winding factor and cause a smaller spatial harmonic content. This leads to lower I2R losses in the stator and the rotor windings, and thus to an increased efficiency. However, compared with an equivalent six-phase winding, additional spatial harmonics are generated due to the different magnetomotive forces in the star and the delta parts of the winding. In this paper, a complete theory and analysis method for the analytical calculation of the efficiency for induction motors equipped with combined star–delta windings is developed. The method takes into account the additional harmonic content due to the different magnetomotive forces in the star and delta parts. To check the analysis’ validity, an experimental test is reported both on a cage induction motor equipped with a combined star–delta winding in the stator and on a reference motor with the same core, but with a classical three-phase winding.
- 12 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 53 (4) , 3579-3587
Prediction of Losses and Efficiency for Three-Phase Induction Machines Equipped With Combined Star–Delta Windings
Combined star–delta windings in electrical machines result in a higher fundamental winding factor and cause a smaller spatial harmonic content. This leads to lower I2R losses in the stator and the rotor windings, and thus to an increased efficiency. However, compared with an equivalent six-phase winding, additional spatial harmonics are generated due to the different magnetomotive forces in the star and the delta parts of the winding. In this paper, a complete theory and analysis method for the analytical calculation of the efficiency for induction motors equipped with combined star–delta windings is developed. The method takes into account the additional harmonic content due to the different magnetomotive forces in the star and delta parts. To check the analysis’ validity, an experimental test is reported both on a cage induction motor equipped with a combined star–delta winding in the stator and on a reference motor with the same core, but with a classical three-phase winding.
- 3 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 166-172
Calculation method of three-phase induction machines equipped with combined star-delta windings
Combined star-delta windings in electrical machines result in a higher fundamental winding factor and cause a smaller spatial harmonic content. This leads to lower I2R losses in the stator and the rotor winding and thus to an increased efficiency. However, compared to an equivalent six-phase winding, additional spatial harmonics are generated due to the different magnetomotive force in the star and delta part of the winding. In this paper, a complete theory and analysis method for the analytical calculation of the efficiency of induction motors equipped with combined star-delta windings is developed. The method takes into account the additional harmonic content due to the different magnetomotive force in the star and delta part. To check the analysis' validity, an experimental test is reported both on a cage induction motor equipped with a combined star-delta winding in the stator and on a reference motor with the same core but with a classical three-phase winding.
- 3 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 166-172
Calculation method of three-phase induction machines equipped with combined star-delta windings
Combined star-delta windings in electrical machines result in a higher fundamental winding factor and cause a smaller spatial harmonic content. This leads to lower I2R losses in the stator and the rotor winding and thus to an increased efficiency. However, compared to an equivalent six-phase winding, additional spatial harmonics are generated due to the different magnetomotive force in the star and delta part of the winding. In this paper, a complete theory and analysis method for the analytical calculation of the efficiency of induction motors equipped with combined star-delta windings is developed. The method takes into account the additional harmonic content due to the different magnetomotive force in the star and delta part. To check the analysis' validity, an experimental test is reported both on a cage induction motor equipped with a combined star-delta winding in the stator and on a reference motor with the same core but with a classical three-phase winding.
- 13 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 52 (5) , 3792-3804
Determination of the Inductances of Salient Pole Synchronous Machines Based on the Voltage Equation of a Single Coil in the Stator Winding
An improved model for calculating the current distribution of salient pole synchronous machines with internal faults in the stator winding is established using the multiloop method. For this purpose, good knowledge of the time-depending inductances is necessary. In this paper, a calculation method is presented to determine the inductances of a salient pole synchronous machine based on the voltage equation of a single coil in the stator winding, in particular, the mutual- and self-inductances of the stator coils, the mutual inductances between the stator coils and the field winding, the self-inductance of the field winding, the mutual inductance between the stator coils and the damper loops, the mutual inductance between the field winding and the damper loops, as well as the mutual inductance between the damper loops. The method presented here considers the analytical calculation of the magnetic flux density based on the magnetomotive force and the time-depending air-gap permeance function of the salient pole synchronous machine. The analytical approach has been validated with the finite-element method and experimental results for two different salient pole synchronous motors.
- 13 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 52 (5) , 3792-3804
Determination of the Inductances of Salient Pole Synchronous Machines Based on the Voltage Equation of a Single Coil in the Stator Winding
An improved model for calculating the current distribution of salient pole synchronous machines with internal faults in the stator winding is established using the multiloop method. For this purpose, good knowledge of the time-depending inductances is necessary. In this paper, a calculation method is presented to determine the inductances of a salient pole synchronous machine based on the voltage equation of a single coil in the stator winding, in particular, the mutual- and self-inductances of the stator coils, the mutual inductances between the stator coils and the field winding, the self-inductance of the field winding, the mutual inductance between the stator coils and the damper loops, the mutual inductance between the field winding and the damper loops, as well as the mutual inductance between the damper loops. The method presented here considers the analytical calculation of the magnetic flux density based on the magnetomotive force and the time-depending air-gap permeance function of the salient pole synchronous machine. The analytical approach has been validated with the finite-element method and experimental results for two different salient pole synchronous motors.