High-resolution monolithic LYSO detector with 6-layer depth-of-interaction for clinical PET
- 30 July 2021
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (15) , 155014
Abstract
The system spatial resolution of whole-body positron emission tomography (PET) is limited to around 2 mm due to positron physics and the large diameter of the bore. To stay below this ‘physics’-limit a scintillation detector with an intrinsic spatial resolution of around 1.3 mm is needed. Currently used detector technology consists of arrays of 2.6–5 mm segmented scintillator pixels which are the dominant factor contributing to the system resolution. Pixelated detectors using smaller pixels exist but face major drawbacks in sensitivity, timing, energy resolution and cost. Monolithic continuous detectors, where the spatial resolution is determined by the shape of the light distribution on the photodetector array, are a promising alternative. Without having the drawbacks of pixelated detectors, monolithic ones can also provide depth-of-interaction (DOI) information. In this work we present a monolithic detector design aiming to serve high-resolution clinical PET systems while maintaining high sensitivity. A 50 × 50 × 16 mm 3 Lutetium–Yttrium oxyorthosilicate scintillation crystal with silicon photomultiplier (SiPM) backside readout is calibrated in singles mode by a collimated beam obtaining a reference dataset for the event positioning. A mean nearest neighbour (MNN) algorithm and an artificial neural network for positioning are compared. The targeted intrinsic detector resolution of 1.3 mm needed to reach a 2 mm resolution on system level was accomplished with both algorithms. The neural network achieved a mean spatial resolution of 1.14 mm FWHM for the whole detector and 1.02 mm in the centre (30 × 30 mm 2 ). The MNN algorithm performed slightly worse with 1.17 mm for the whole detector and 1.13 mm in the centre. The intrinsic DOI information will also result in uniform system spatial resolution over the full field of view.Keywords
Funding Information
- Sphynx (BOF.COF.2018.0002.01)
- ERA-Net PHOTONICS (AIO.ONO.2018.0003.01)
- Fonds Wetenschappelijk Onderzoek (FWO.HZW.2018.0001.01)
This publication has 43 references indexed in Scilit:
- Experimental Validation of an Efficient Fan-Beam Calibration Procedure for $k$-Nearest Neighbor Position Estimation in Monolithic Scintillator DetectorsIEEE Transactions on Nuclear Science, 2015
- Multiplexing strategies for monolithic crystal PET detector modulesPhysics in Medicine & Biology, 2014
- DigiPET: sub-millimeter spatial resolution small-animal PET imaging using thin monolithic scintillatorsPhysics in Medicine & Biology, 2014
- Influence of detector pixel size, TOF resolution and DOI on image quality in MR-compatible whole-body PETPhysics in Medicine & Biology, 2013
- Fast calibration of SPECT monolithic scintillation detectors using un-collimated sourcesPhysics in Medicine & Biology, 2013
- Sparse Signal Recovery Methods for Multiplexing PET Detector ReadoutIEEE Transactions on Medical Imaging, 2013
- 3D position estimation using an artificial neural network for a continuous scintillator PET detectorPhysics in Medicine & Biology, 2013
- Depth of interaction decoding of a continuous crystal detector modulePhysics in Medicine & Biology, 2007
- Towards a continuous crystal APD-based PET detector designNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007
- Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolutionPhysics in Medicine & Biology, 2000