Improved absolute frequency measurement of the strontium ion clock using a GPS link to the SI second
- 25 November 2022
- journal article
- research article
- Published by IOP Publishing in Metrologia
- Vol. 60 (1) , 015007
Abstract
We report on an improved absolute frequency measurement of the 5 s 2 S 1 / 2 – 4 d 2 D 5 / 2 optical transition of a single trapped strontium ion using a Global Positioning System (GPS) link to the SI second. Compared to our previous measurement, the systematic uncertainty of the optical clock has been reduced from 1.5 × 10 − 17 to 1.2 × 10 − 17 . The measurement campaign was performed over a two-week period in June 2017, with a total measurement time of 92 h. The traceability to the SI second through International Atomic Time was achieved through a GPS link using the Precise Point Positioning method. The dead time uncertainty of the link between the optical clock and the maser was evaluated using standard methods based on a model of the maser noise and on the optical frequency measurement uptimes. The measured frequency of the 88Sr+ ion 5 s 2 S 1 / 2 – 4 d 2 D 5 / 2 transition is 444 779 044 095 485.49 ( 19 ) Hz. This result is in excellent agreement with our previous measurements and the uncertainty has been reduced by almost a factor of four, from a fractional frequency uncertainty of 1.7 × 10 − 15 to 4.3 × 10 − 16 .Keywords
This publication has 54 references indexed in Scilit:
- Absolute frequency measurement of1S0(F= 1/2)–3P0(F= 1/2) transition of171Yb atoms in a one-dimensional optical lattice at KRISSMetrologia, 2013
- Improved accuracy of the NPL-CsF2 primary frequency standard: evaluation of distributed cavity phase and microwave lensing frequency shiftsMetrologia, 2011
- A theoretical and experimental analysis of frequency transfer uncertainty, including frequency transfer into TAIMetrologia, 2010
- First accuracy evaluation of the NPL-CsF2 primary frequency standardMetrologia, 2010
- Fiber-laser-based clockwork for long-term measurements and comparisons of visible optical frequency standardsThe European Physical Journal D, 2010
- Uncertainty evaluation of the caesium fountain clock PTB-CSF2Metrologia, 2009
- Uncertainty of a frequency comparison with distributed dead time and measurement interval offsetMetrologia, 2007
- Influence of Chirped Excitation Pulses in an Optical Clock With Ultracold Calcium AtomsIEEE Transactions on Instrumentation and Measurement, 2005
- Hertz-Level Measurement of the Optical Clock Frequency in a Single 88 Sr + IonScience, 2004
- Measurement of the Electric Quadrupole Moment of theLevel inPhysical Review Letters, 2004