Pierre Dubé
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Pierre Dubé has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Marina Gertsvolf
National Research Council Canada, Ottawa, ON K1A 0R6, Canada
3 shared publications - Bin Jian
Metrology Research Centre, National Research Council Canada
2 shared publications - Kosuke Kato
National Research Council Canada, Metrology Research Centre, Ottawa, Ontario K1A 0R6, Canada
2 shared publications A Malimon
VNIIFTRI, Mendeleevo, Moskovskaâ, RUSSIAN FEDERATION
1 shared publication- Amar C. Vutha
University of Toronto
1 shared publication B. P. Stoicheff
Department of Physics, University of Toronto, and Ontario Laser and Lightwave Research Centre, Toronto, Ontario M5S 1A7, Canada
1 shared publication
Latest Publications
- Open Access
- 25 June 2025
- Published by IOP Publishing in Metrologia
- Vol. 62 (4) , 045001
Absolute frequency measurement of a 88Sr+ clock by direct comparison to a primary frequency standard
We report on a measurement of the absolute frequency of the 88Sr+ clock transition via a direct comparison to our cesium fountain clock, National Research Council Canada (NRC)-FCs2. The measurement yield a value of 444 779 044 095 485.404 ± 0.045 Hz. The corresponding fractional uncertainty of 1.0 × 10 − 16 is, to our knowledge, the lowest so far reported for an absolute frequency measurement. The low uncertainty obtained is primarily a consequence of improvements to NRC-FCs2, specifically a systematic uncertainty of 9.3 × 10 − 17 and a stability of 6.3 × 10 − 14 / τ . The measurement was made over a period of 37 days with 68% uptime, for a total measurement time of 2.16 × 10 6 s. The 88Sr+ frequency was also compared to terrestrial time via a global navigation satellite system (GNSS) link to Universal Coordinated Time, yielding a frequency value of 444 779 044 095 485.406 ± 0.089 Hz, which is in agreement with the direct comparison with NRC-FCs2.
- 25 June 2025
- Published by IOP Publishing in Metrologia
- Vol. 62 (4) , 045001
Open AccessAbsolute frequency measurement of a 88Sr+ clock by direct comparison to a primary frequency standard
We report on a measurement of the absolute frequency of the 88Sr+ clock transition via a direct comparison to our cesium fountain clock, National Research Council Canada (NRC)-FCs2. The measurement yield a value of 444 779 044 095 485.404 ± 0.045 Hz. The corresponding fractional uncertainty of 1.0 × 10 − 16 is, to our knowledge, the lowest so far reported for an absolute frequency measurement. The low uncertainty obtained is primarily a consequence of improvements to NRC-FCs2, specifically a systematic uncertainty of 9.3 × 10 − 17 and a stability of 6.3 × 10 − 14 / τ . The measurement was made over a period of 37 days with 68% uptime, for a total measurement time of 2.16 × 10 6 s. The 88Sr+ frequency was also compared to terrestrial time via a global navigation satellite system (GNSS) link to Universal Coordinated Time, yielding a frequency value of 444 779 044 095 485.406 ± 0.089 Hz, which is in agreement with the direct comparison with NRC-FCs2.
- Top Cited PapersOpen Access
- 22 January 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (1) , 012001
Roadmap towards the redefinition of the second
This paper outlines the roadmap towards the redefinition of the second, which was recently updated by the CCTF Task Force created by the CCTF in 2020. The main achievements of optical frequency standards (OFS) call for reflection on the redefinition of the second, but open new challenges related to the performance of the OFS, their contribution to time scales and UTC, the possibility of their comparison, and the knowledge of the Earth’s gravitational potential to ensure a robust and accurate capacity to realize a new definition at the level of 10−18uncertainty. The mandatory criteria to be achieved before redefinition have been defined and their current fulfilment level is estimated showing the fields that still needed improvement. The possibility to base the redefinition on a single or on a set of transitions has also been evaluated. The roadmap indicates the steps to be followed in the next years to be ready for a sound and successful redefinition.
- 22 January 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (1) , 012001
Top Cited PapersOpen AccessRoadmap towards the redefinition of the second
This paper outlines the roadmap towards the redefinition of the second, which was recently updated by the CCTF Task Force created by the CCTF in 2020. The main achievements of optical frequency standards (OFS) call for reflection on the redefinition of the second, but open new challenges related to the performance of the OFS, their contribution to time scales and UTC, the possibility of their comparison, and the knowledge of the Earth’s gravitational potential to ensure a robust and accurate capacity to realize a new definition at the level of 10−18uncertainty. The mandatory criteria to be achieved before redefinition have been defined and their current fulfilment level is estimated showing the fields that still needed improvement. The possibility to base the redefinition on a single or on a set of transitions has also been evaluated. The roadmap indicates the steps to be followed in the next years to be ready for a sound and successful redefinition.
- 15 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Development of Room Temperature and Cryogenic Strontium Ion Clocks With Low Uncertainties
SummaryWe are developing a transportable room temperature strontium ion clock at the National Research Council Canada (NRC) and a laboratory-based cryogenic strontium ion clock at the University of Toronto. These clocks are designed to minimize the systematic frequency shifts and meet the mandatory accuracy criteria for the redefinition of the SI second. The expected performances of the new optical clocks are compared to the well-characterized NRC strontium ion frequency standard that has been operational for more than a decade.
- 15 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Development of Room Temperature and Cryogenic Strontium Ion Clocks With Low Uncertainties
SummaryWe are developing a transportable room temperature strontium ion clock at the National Research Council Canada (NRC) and a laboratory-based cryogenic strontium ion clock at the University of Toronto. These clocks are designed to minimize the systematic frequency shifts and meet the mandatory accuracy criteria for the redefinition of the SI second. The expected performances of the new optical clocks are compared to the well-characterized NRC strontium ion frequency standard that has been operational for more than a decade.
- 25 November 2022
- Published by IOP Publishing in Metrologia
- Vol. 60 (1) , 015007
Improved absolute frequency measurement of the strontium ion clock using a GPS link to the SI second
We report on an improved absolute frequency measurement of the 5 s 2 S 1 / 2 – 4 d 2 D 5 / 2 optical transition of a single trapped strontium ion using a Global Positioning System (GPS) link to the SI second. Compared to our previous measurement, the systematic uncertainty of the optical clock has been reduced from 1.5 × 10 − 17 to 1.2 × 10 − 17 . The measurement campaign was performed over a two-week period in June 2017, with a total measurement time of 92 h. The traceability to the SI second through International Atomic Time was achieved through a GPS link using the Precise Point Positioning method. The dead time uncertainty of the link between the optical clock and the maser was evaluated using standard methods based on a model of the maser noise and on the optical frequency measurement uptimes. The measured frequency of the 88Sr+ ion 5 s 2 S 1 / 2 – 4 d 2 D 5 / 2 transition is 444 779 044 095 485.49 ( 19 ) Hz. This result is in excellent agreement with our previous measurements and the uncertainty has been reduced by almost a factor of four, from a fractional frequency uncertainty of 1.7 × 10 − 15 to 4.3 × 10 − 16 .
- 25 November 2022
- Published by IOP Publishing in Metrologia
- Vol. 60 (1) , 015007
Improved absolute frequency measurement of the strontium ion clock using a GPS link to the SI second
We report on an improved absolute frequency measurement of the 5 s 2 S 1 / 2 – 4 d 2 D 5 / 2 optical transition of a single trapped strontium ion using a Global Positioning System (GPS) link to the SI second. Compared to our previous measurement, the systematic uncertainty of the optical clock has been reduced from 1.5 × 10 − 17 to 1.2 × 10 − 17 . The measurement campaign was performed over a two-week period in June 2017, with a total measurement time of 92 h. The traceability to the SI second through International Atomic Time was achieved through a GPS link using the Precise Point Positioning method. The dead time uncertainty of the link between the optical clock and the maser was evaluated using standard methods based on a model of the maser noise and on the optical frequency measurement uptimes. The measured frequency of the 88Sr+ ion 5 s 2 S 1 / 2 – 4 d 2 D 5 / 2 transition is 444 779 044 095 485.49 ( 19 ) Hz. This result is in excellent agreement with our previous measurements and the uncertainty has been reduced by almost a factor of four, from a fractional frequency uncertainty of 1.7 × 10 − 15 to 4.3 × 10 − 16 .
- 1 January 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (1A)
Calibration of gauge blocks by optical interferometry comparison - final report
Main text: Gauge blocks are one of the main artifacts used to calibrate length measuring instruments. The highest grade gauge blocks are calibrated by interferometry making them traceable to the length unit, the metre. The transfer of the wavelength of light to these artifacts is a challenging calibration that requires state-of-the-art equipment, good control of ambient conditions and knowledgeable personnel. It is one of the main calibration services offered by National Metrology Institutes. The Consultative Committee for Length (CCL) has established key comparisons as a means for assuring world-wide traceability and equivalence of length measurements at the highest levels of accuracy. In the key comparison reported here, there were twelve participants from EURAMET, COOMET, AFRIMET, APMP, and SIM regions. This comparison was based on the circulation of seven short steel gauge blocks, six short ceramic gauge blocks, and three steel long gauge blocks. The exercise was successful, and the results of the participants are reported here. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 1 January 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (1A)
Calibration of gauge blocks by optical interferometry comparison - final report
Main text: Gauge blocks are one of the main artifacts used to calibrate length measuring instruments. The highest grade gauge blocks are calibrated by interferometry making them traceable to the length unit, the metre. The transfer of the wavelength of light to these artifacts is a challenging calibration that requires state-of-the-art equipment, good control of ambient conditions and knowledgeable personnel. It is one of the main calibration services offered by National Metrology Institutes. The Consultative Committee for Length (CCL) has established key comparisons as a means for assuring world-wide traceability and equivalence of length measurements at the highest levels of accuracy. In the key comparison reported here, there were twelve participants from EURAMET, COOMET, AFRIMET, APMP, and SIM regions. This comparison was based on the circulation of seven short steel gauge blocks, six short ceramic gauge blocks, and three steel long gauge blocks. The exercise was successful, and the results of the participants are reported here. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- Open Access
- 8 November 1995
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 103 (18) , 7708-7721
Spectroscopic study of vibrational relaxation and cooling of rare-gas excimers formed in a direct current discharge with supersonic expansion
Emission spectra (in the region 100–200 nm) of the excimers Ar2*, Kr2*, and Xe2* produced in a dc jet discharge with supersonic expansion were used to determine vibrational temperatures of the excimers, and to analyze the process of excimer relaxation from high vibrational levels near dissociation of the A3Σ+u(1u) states to the lowest levels. The observed narrow bandwidths of the second continua yielded population distributions with at least 80% in the v=0 levels at thermal equilibrium, for all three gases, corresponding to vibrational temperatures of 280, 95, and 82 K for Ar2*, Kr2*, and Xe2*, respectively. Changes in relative intensities of the first and second continua with pressure were monitored by optical pumping of atoms in the 1s5 metastable level [precursor of the excimer A3Σ+u(1u) state], and the resulting difference spectra were analyzed in terms of vibrational relaxation to the v∼0 levels. A simple model based on collisional relaxation was developed to calculate the VUV band spectra. Comparisons of the Ar2* spectra with the model showed that vibrational relaxation accounted for the observed difference spectra, up to plenum pressures of ∼7 atm. Departures from this model at higher pressures for Ar2*, and particularly the observed behavior of Kr2* and Xe2* difference spectra, indicated that populations in the lowest vibrational levels were affected by additional processes, and not only by vibrational relaxation of excimers formed by association.
- 8 November 1995
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 103 (18) , 7708-7721
Open AccessSpectroscopic study of vibrational relaxation and cooling of rare-gas excimers formed in a direct current discharge with supersonic expansion
Emission spectra (in the region 100–200 nm) of the excimers Ar2*, Kr2*, and Xe2* produced in a dc jet discharge with supersonic expansion were used to determine vibrational temperatures of the excimers, and to analyze the process of excimer relaxation from high vibrational levels near dissociation of the A3Σ+u(1u) states to the lowest levels. The observed narrow bandwidths of the second continua yielded population distributions with at least 80% in the v=0 levels at thermal equilibrium, for all three gases, corresponding to vibrational temperatures of 280, 95, and 82 K for Ar2*, Kr2*, and Xe2*, respectively. Changes in relative intensities of the first and second continua with pressure were monitored by optical pumping of atoms in the 1s5 metastable level [precursor of the excimer A3Σ+u(1u) state], and the resulting difference spectra were analyzed in terms of vibrational relaxation to the v∼0 levels. A simple model based on collisional relaxation was developed to calculate the VUV band spectra. Comparisons of the Ar2* spectra with the model showed that vibrational relaxation accounted for the observed difference spectra, up to plenum pressures of ∼7 atm. Departures from this model at higher pressures for Ar2*, and particularly the observed behavior of Kr2* and Xe2* difference spectra, indicated that populations in the lowest vibrational levels were affected by additional processes, and not only by vibrational relaxation of excimers formed by association.