Robot-assisted total hip arthroplasty
Authors:
- 21 December 2015
- journal article
- review article
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 13 (1) , 47-56
Abstract
Precise and accurate biomechanical reconstruction during total hip arthroplasty (THA) is essential for durable long-term survivorship. Accurate fit of cementless hip implants is also crucial to reduce micromotion between the bone-implant interfaces to allow for stable osseointegration. Robotic technology aims to minimize potential human errors and improve implant alignment and fit, and address persisting concerns with modern-day cementless THA. Although robotic THA dates back to the early 1990s, concerns with increased operating times, costs, and complications led to its withdrawal. However, semi-active systems have renewed interest in robot-assisted joint arthroplasty. We reviewed the current technology, its potential benefits, and the reported clinical and radiographic outcomes. Early evidence suggests that robotic use may lead to more accurate reconstruction of radiographic parameters, such as implant positioning, fit, center-of-rotation, and leg-length discrepancy. Further research is needed to determine if these will translate into better outcomes and improved implant longevity to justify increased costs.Keywords
This publication has 41 references indexed in Scilit:
- Alpharetroviral Self-inactivating Vectors: Long-term Transgene Expression in Murine Hematopoietic Cells and Low GenotoxicityMolecular Therapy, 2012
- Cementless Femoral Fixation in Total Hip ArthroplastyJournal of Bone and Joint Surgery, 2011
- Influence of prosthesis design and implantation technique on implant stresses after cementless revision THRJournal of Orthopaedic Surgery and Research, 2011
- Metal neck and liner impingement in ceramic bearing total hip arthroplastyJournal of Orthopaedic Research, 2010
- Survivorship of 2000 Tapered Titanium Porous Plasma-sprayed Femoral ComponentsClinical Orthopaedics and Related Research, 2009
- Aseptic stem loosening in primary THA: migration analysis of cemented and cementless fixationInternational Orthopaedics, 2008
- Orientation and wear of the acetabular component in third generation alumina-on-alumina ceramic bearingsThe Journal of Bone and Joint Surgery. British volume, 2007
- The dimensional accuracy for preparation of the femoral cavity in HIP arthroplastyArchives of orthopaedic and trauma surgery, 2005
- Anterior thigh pain after cementless total hip arthroplastyInternational Orthopaedics, 2005
- Late Loosening of Press-Fit Cementless Acetabular ComponentsClinical Orthopaedics and Related Research, 2004