Impact of Mixing on Content Uniformity of Thin Polymer Films Containing Drug Micro-Doses
Open Access
- 29 May 2021
- journal article
- research article
- Published by MDPI AG in Pharmaceutics
- Vol. 13 (6) , 812
Abstract
The impact of mixer type and critical process parameters (CPPs) on critical quality attributes (CQAs), including the drug content uniformity (CU) of slurry-cast polymer films loaded with micro-sized poorly water-soluble drugs were investigated. Previously untested hypothesis was that the best mixer at suitable CPPs promotes uniform drug dispersion within film precursors leading to acceptable dried-film CU at low, ~0.6 wt% drug concentrations. Taguchi design was utilized to select the best of three mixers; low-shear impeller, high-shear planetary, and high-intensity vibrational, for dried-film drug concentration of ~23 wt%. As-received fenofibrate, a model poorly water-soluble drug (~6 µm) was directly mixed with the hydroxypropyl methylcellulose (HPMC) and glycerin aqueous solution. Impeller and planetary mixers yielded desirable film relative standard deviation (RSD), while vibrational mixer could not. For the lowest dried-film drug concentration of ~0.6 wt%, only planetary mixer yielded RSD <6%. The precursor drug homogeneity was a sufficient but not a necessary condition for achieving dried-film RSD <6%. Thus, proper selection of mixer and its CPPs assured desirable film CQAs. However, minor drug particle aggregation was identified via re-dispersion testing which also led to incomplete drug release.Keywords
Funding Information
- National Science Foundation ([EEC-0540855] and [IIP-1919037])
This publication has 42 references indexed in Scilit:
- Incorporation of surface-modified dry micronized poorly water-soluble drug powders into polymer strip filmsInternational Journal of Pharmaceutics, 2018
- Critical material attributes (CMAs) of strip films loaded with poorly water-soluble drug nanoparticles: III. Impact of drug nanoparticle loadingInternational Journal of Pharmaceutics, 2017
- Critical Material Attributes of Strip Films Loaded With Poorly Water-Soluble Drug Nanoparticles: II. Impact of Polymer Molecular WeightJournal of Pharmaceutical Sciences, 2017
- Critical material attributes (CMAs) of strip films loaded with poorly water-soluble drug nanoparticles: I. Impact of plasticizer on film properties and dissolutionEuropean Journal of Pharmaceutical Sciences, 2016
- Preparation of an oral thin film containing meclizine hydrochloride: In vitro and in vivo evaluationInternational Journal of Pharmaceutics, 2015
- Preparation and characterization of fast dissolving pullulan films containing BCS class II drug nanoparticles for bioavailability enhancementDrug Development and Industrial Pharmacy, 2015
- Polymer strip films as a robust, surfactant-free platform for delivery of BCS Class II drug nanoparticlesInternational Journal of Pharmaceutics, 2015
- Preparation and characterization of hydroxypropyl methyl cellulose films containing stable BCS Class II drug nanoparticles for pharmaceutical applicationsInternational Journal of Pharmaceutics, 2012
- Oral strip technology: Overview and future potentialJournal of Controlled Release, 2009
- Production and Characterization of Hot-Melt Extruded Films Containing ClotrimazoleDrug Development and Industrial Pharmacy, 2003