In vitro evaluation of a low-modulus mesh canine prosthetic hip stem
Authors:
- Denis J. Marcellin-LittleDMDenis J. Marcellin-Little
- Omer CansizogluOCOmer Cansizoglu
- Ola L. A. HarryssonOHOla L. A. Harrysson
- Simon C. RoeSRSimon C. Roe
- 1 September 2010
- journal article
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 71 (9) , 1089-1095
Abstract
Objective—To compare an electron beam melting-processed (EBMP) low-modulus titanium alloy mesh stem with a commercial cobalt-chromium (CC) stem in a canine cadaver model. Sample Population—9 pairs of cadaver femora. Procedures—EBMP stems of 3 sizes were placed in randomly chosen sides of femora (left or right) and CC stems in opposite sides. Stem impaction distances were recorded. Five strain gauges were attached to the femoral surface to record transverse tensile (hoop) strains in the femur during axial loading. Constructs were axially loaded 4 times to 800 N and 4 times to 1,600 N in a materials testing machine. Axial stiffness of constructs and bone surface strains were compared between EBMP and CC constructs. Results—Stems were impacted without creating femoral fissures or fractures. Stem impaction distances were larger for EBMP stems than for CC stems. Mean axial stiffness of EBMP constructs was lower than mean axial stiffness of CC constructs. Subsidence did not differ between groups. Bone strains varied among strain gauge positions and were largest at the distal aspect of the stems. At a load of 1,600 N, bones strains were higher in CC constructs than in EBMP constructs for 2 of 4 medial strain gauges. Conclusions and Clinical Relevance—EBMP stems were successfully impacted and stable and led to a focal decrease in bone strain; this may represent an acceptable option for conventional or custom joint replacement. (Am J Vet Res 2010;71:1089–1095) Although cemented hip stems have been used successfully as part of total hip replacements in humans, their success rate has been reportedly lower in younger patients than in older patients.1 The longterm success of hip stems is affected by aseptic implant loosening, implant wear, and stress-mediated bone resorption (stress shielding).2 Cementless hip stems were originally developed in part because polymethylmethacrylate bone cement was considered to be a contributing factor to aseptic loosening of cemented hip stems.3 A portion of a cementless stem is textured or coated with porous surfaces for bone ongrowth and ingrowth.4,5 Stem stability relies on initial press fit and long-term bone ingrowth into the porous portions of the stems. Cementless stems are large and have a highKeywords
This publication has 33 references indexed in Scilit:
- In vitro evaluation of a custom cutting jig and custom plate for canine tibial plateau levelingAmerican Journal of Veterinary Research, 2008
- Signalment differences in bone mineral content and bone mineral density in canine appendicular bonesVeterinary and Comparative Orthopaedics and Traumatology, 2008
- Characterization of H13 steel produced via electron beam meltingRapid Prototyping Journal, 2004
- The Effects of Implant Orientation, Canal Fill, and Implant Fit on Femoral Strain Patterns and Implant Stability During Catastrophic Testing of a Canine Cementless Femoral ProsthesisVeterinary Surgery, 1995
- Effects of Fit and Bonding Characteristics of Femoral Stems on Adaptive Bone RemodelingJournal of Biomechanical Engineering, 1994
- Femoral Strain Distribution and Subsidence After Physiological Loading of a Cementless Canine Femoral Prosthesis: The Effects of Implant Orientation, Canal Fill, and Implant FitVeterinary Surgery, 1994
- Strain Redistribution in the Canine Femur Resulting from Hip Implants of Different StiffnessesJournal of Investigative Surgery, 1994
- Determination of loading parameters in the canine hip in vivoJournal of Biomechanics, 1993
- Subsidence of an Uncemented Canine Femoral StemVeterinary Surgery, 1992
- Alterations in femoral and acetabular bone strains immediately following cementless total hip arthroplasty: An in vitro canine studyJournal of Orthopaedic Research, 1991