A review of PET attenuation correction methods for PET-MR
Open Access
- 11 September 2023
- journal article
- review article
- Published by Springer Nature in EJNMMI Physics
- Vol. 10 (1) , 1-45
Abstract
Despite being thirteen years since the installation of the first PET-MR system, the scanners constitute a very small proportion of the total hybrid PET systems installed. This is in stark contrast to the rapid expansion of the PET-CT scanner, which quickly established its importance in patient diagnosis within a similar timeframe. One of the main hurdles is the development of an accurate, reproducible and easy-to-use method for attenuation correction. Quantitative discrepancies in PET images between the manufacturer-provided MR methods and the more established CT- or transmission-based attenuation correction methods have led the scientific community in a continuous effort to develop a robust and accurate alternative. These can be divided into four broad categories: (i) MR-based, (ii) emission-based, (iii) atlas-based and the (iv) machine learning-based attenuation correction, which is rapidly gaining momentum. The first is based on segmenting the MR images in various tissues and allocating a predefined attenuation coefficient for each tissue. Emission-based attenuation correction methods aim in utilising the PET emission data by simultaneously reconstructing the radioactivity distribution and the attenuation image. Atlas-based attenuation correction methods aim to predict a CT or transmission image given an MR image of a new patient, by using databases containing CT or transmission images from the general population. Finally, in machine learning methods, a model that could predict the required image given the acquired MR or non-attenuation-corrected PET image is developed by exploiting the underlying features of the images. Deep learning methods are the dominant approach in this category. Compared to the more traditional machine learning, which uses structured data for building a model, deep learning makes direct use of the acquired images to identify underlying features. This up-to-date review goes through the literature of attenuation correction approaches in PET-MR after categorising them. The various approaches in each category are described and discussed. After exploring each category separately, a general overview is given of the current status and potential future approaches along with a comparison of the four outlined categories.Keywords
Funding Information
- Wellcome Trust (WT 203148/A/16/Z)
- Centre For Medical Engineering, King’s College London (WT 203148/A/16/Z)
This publication has 304 references indexed in Scilit:
- MRI for attenuation correction in PET: methods and challengesMagnetic Resonance Materials in Physics, Biology and Medicine, 2012
- Evaluation of an attenuation correction method for PET/MR imaging of the head based on substitute CT imagesMagnetic Resonance Materials in Physics, Biology and Medicine, 2012
- MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRIJournal of Nuclear Medicine, 2012
- MRI-Based Attenuation Correction for Hybrid PET/MRI Systems: A 4-Class Tissue Segmentation Technique Using a Combined Ultrashort-Echo-Time/Dixon MRI SequenceJournal of Nuclear Medicine, 2012
- Free-Breathing 3D T1-Weighted Gradient-Echo Sequence With Radial Data Sampling in Abdominal MRI: Preliminary ObservationsAmerican Journal of Roentgenology, 2011
- Three-region MRI-based whole-body attenuation correction for automated PET reconstructionNuclear Medicine and Biology, 2010
- Comparison of low‐pitch and respiratory‐averaged CT protocols for attenuation correction of cardiac PET studiesMedical Physics, 2009
- Parallel acquisition techniques for accelerated volumetric interpolated breath‐hold examination magnetic resonance imaging of the upper abdomen: Assessment of image quality and lesion conspicuityJournal of Magnetic Resonance Imaging, 2005
- Reconstruction of attenuation map using discrete consistency conditionsIEEE Transactions on Medical Imaging, 2000
- Simultaneous maximum a posteriori reconstruction of attenuation and activity distributions from emission sinogramsIEEE Transactions on Medical Imaging, 1999