GKGeorgios Krokos

Georgios Krokos

*This is an algorithmically generated author record based on publicly available information.

Georgios Krokos has a total of 43 co-authors. Here are the top co-authors by number of shared publications:

  • Gary James R. Cook

    School of Biomedical Engineering and Imaging Sciences, King’s College London, London, UK

    2 shared publications
  • Jane MacKewn

    School of Biomedical Engineering and Imaging Sciences, The PET Centre at St Thomas’ Hospital London, King’s College London, London, UK

    2 shared publications
  • Paul K. Marsden

    School of Biomedical Engineering & Imaging Sciences, King's College London, 4th Floor, Lambeth Wing, St Thomas' Hospital, Lambeth Road Palace, London, SE1 7EH, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND

    2 shared publications
  • Afnan Malaih

    Department of Biomedical Engineering , King's College London Faculty of Life Sciences & Medicine, St Thomas' Hospital, Westminster Bridge Road, London, Greater London, SE1 1UL, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND

    1 shared publication
  • Alexander Hammers

    King’s College London

    1 shared publication
  • Amedeo Chiribiri

    Guy’s and St Thomas’ Hospital & School of Biomedical Engineering and Imaging Sciences, King’s College London Department of Cardiology Westminster Bridge Road, London SE1 7EH

    1 shared publication

Latest Publications

  • Foundations of PET/MR

    by Sami Jeljeli, Gary Cook, Alexander Hammers, Amedeo Chiribiri, Harriet Rogers, Shawna Kinsella, Georgios Krokos, Radhouene Neji


  • Open Access

    Evaluation of manual and automated approaches for segmentation and extraction of quantitative indices from [18F]FDG PET-CT images

    by Georgios Krokos, Tejas Kotwal, Afnan Malaih, Sally Barrington, Price Jackson, Rodney J Hicks, Paul K Marsden, Barbara Malene Fischer

    Utilisation of whole organ volumes to extract anatomical and functional information from computed tomography (CT) and positron emission tomography (PET) images may provide key information for the treatment and follow-up of cancer patients. However, manual organ segmentation, is laborious and time-consuming. In this study, a CT-based deep learning method and a multi-atlas method were evaluated for segmenting the liver and spleen on CT images to extract quantitative tracer information from Fluorine-18 fluorodeoxyglucose ([18F]FDG) PET images of 50 patients with advanced Hodgkin lymphoma (HL). Manual segmentation was used as the reference method. The two automatic methods were also compared with a manually defined volume of interest (VOI) within the organ, a technique commonly performed in clinical settings. Both automatic methods provided accurate CT segmentations, with the deep learning method outperforming the multi-atlas with a DICE coefficient of 0.93 ± 0.03 (mean ± standard deviation) in liver and 0.87 ± 0.17 in spleen compared to 0.87 ± 0.05 (liver) and 0.78 ± 0.11 (spleen) for the multi-atlas. Similarly, a mean relative error of −3.2% for the liver and −3.4% for the spleen across patients was found for the mean standardized uptake value (SUVmean) using the deep learning regions while the corresponding errors for the multi-atlas method were −4.7% and −9.2%, respectively. For the maximum SUV (SUVmax), both methods resulted in higher than 20% overestimation due to the extension of organ boundaries to include neighbouring, high-uptake regions. The conservative VOI method which did not extend into neighbouring tissues, provided a more accurate SUVmax estimate. In conclusion, the automatic, and particularly the deep learning method could be used to rapidly extract information of the SUVmean within the liver and spleen. However, activity from neighbouring organs and lesions can lead to high biases in SUVmax and current practices of manually defining a volume of interest in the organ should be considered instead.


  • Open Access

    A review of PET attenuation correction methods for PET-MR

    by Georgios Krokos, Jane MacKewn, Joel Dunn, Paul Marsden

    Despite being thirteen years since the installation of the first PET-MR system, the scanners constitute a very small proportion of the total hybrid PET systems installed. This is in stark contrast to the rapid expansion of the PET-CT scanner, which quickly established its importance in patient diagnosis within a similar timeframe. One of the main hurdles is the development of an accurate, reproducible and easy-to-use method for attenuation correction. Quantitative discrepancies in PET images between the manufacturer-provided MR methods and the more established CT- or transmission-based attenuation correction methods have led the scientific community in a continuous effort to develop a robust and accurate alternative. These can be divided into four broad categories: (i) MR-based, (ii) emission-based, (iii) atlas-based and the (iv) machine learning-based attenuation correction, which is rapidly gaining momentum. The first is based on segmenting the MR images in various tissues and allocating a predefined attenuation coefficient for each tissue. Emission-based attenuation correction methods aim in utilising the PET emission data by simultaneously reconstructing the radioactivity distribution and the attenuation image. Atlas-based attenuation correction methods aim to predict a CT or transmission image given an MR image of a new patient, by using databases containing CT or transmission images from the general population. Finally, in machine learning methods, a model that could predict the required image given the acquired MR or non-attenuation-corrected PET image is developed by exploiting the underlying features of the images. Deep learning methods are the dominant approach in this category. Compared to the more traditional machine learning, which uses structured data for building a model, deep learning makes direct use of the acquired images to identify underlying features. This up-to-date review goes through the literature of attenuation correction approaches in PET-MR after categorising them. The various approaches in each category are described and discussed. After exploring each category separately, a general overview is given of the current status and potential future approaches along with a comparison of the four outlined categories.


  • Open Access

    Standardisation of conventional and advanced iterative reconstruction methods for Gallium-68 multi-centre PET-CT trials

    by Georgios Krokos, Lucy C. Pike, Gary J. R. Cook, Paul K. Marsden

    Purpose: To assess the applicability of the Fluorine-18 performance specifications defined by EANM Research Ltd (EARL), in Gallium-68 multi-centre PET-CT trials using conventional (ordered subset expectation maximisation, OSEM) and advanced iterative reconstructions which include the systems’ point spread function (PSF) and a Bayesian penalised likelihood algorithm (BPL) commercially known as Q.CLEAR. The possibility of standardising the two advanced reconstruction methods was examined. Methods: The NEMA image quality phantom was filled with Gallium-68 and scanned on a GE PET-CT system. PSF and BPL with varying post-reconstruction Gaussian filter width (2–6.4 mm) and penalisation factor (200–1200), respectively, were applied. The average peak-to-valley ratio from six profiles across each sphere was estimated to inspect any edge artefacts. Image noise was assessed using background variability and image roughness. Six GE and Siemens PET-CT scanners provided Gallium-68 images of the NEMA phantom using both conventional and advanced reconstructions from which the maximum, mean and peak recoveries were drawn. Fourteen patients underwent 68Ga-PSMA PET-CT imaging. BPL (200-1200) reconstructions of the data were compared against PSF smoothed with a 6.4-mm Gaussian filter. Results: A Gaussian filter width of approximately 6 mm for PSF and a penalisation factor of 800 for BPL were needed to suppress the edge artefacts. In addition, those reconstructions provided the closest agreement between the two advanced iterative reconstructions and low noise levels with the background variability and the image roughness being lower than 7.5% and 11.5%, respectively. The recoveries for all methods generally performed at the lower limits of the EARL specifications, especially for the 13- and 10-mm spheres for which up to 27% (conventional) and 41% (advanced reconstructions) lower limits are suggested. The lesion standardised uptake values from the clinical data were significantly different between BPL and PSF smoothed with a Gaussian filter of 6.4 mm wide for all penalisation factors except for 800 and 1000. Conclusion: It is possible to standardise the advanced reconstruction methods with the reconstruction parameters being also sufficient for minimising the edge artefacts and noise in the images. For both conventional and advanced reconstructions, Gallium-68 specific recovery coefficient limits were required, especially for the smallest phantom spheres.


  • Open Access

    Artificial Intelligence for the Characterization of Pulmonary Nodules, Lung Tumors and Mediastinal Nodes on PET/CT

    by Marie Manon Krebs Krarup, Georgios Krokos, Manil Subesinghe, Arjun Nair, Barbara Malene Fischer


  • Qualification of the Seven Dementias Platform UK PET-MR Scanners for Multicentre Trials

    by Georgios Krokos, Jane MacKewn, Lucy Pike, William Hallett, Pawel Markiewicz, Anna Barnes, Marilena Rega, Tim D. Fryer, Roido Manavaki, Jose M. Anton-Rodriguez, et al.

    Standardisation of PET scanners participating in multicentre trials is important in achieving reliable results and in maximizing the power of the study. The first multicentre clinical trial studies involving seven PET-MR scanners in the UK (four GE SIGNA and three Siemens mMR) are underway, led by Dementias Platform UK. In this study, the qualification of the seven scanners was tested using the NEMA image quality phantom. Consistent scanning methodology was followed across all sites with a 5:1 sphere-to-background contrast ratio and a CT-based μ-map used for attenuation correction. The reconstruction parameters were consistent between scanners of the same manufacturer. The SUVmean and SUVmax for all spheres were comparable between all scanners and within EARL performance specifications. Moreover, the averaged SUV values from all scanners were similar with the averaged corresponding values from 25 PET-CT scanners across the UK currently eligible to participate in multicentre trials. In conclusion, these preliminary results support the reliable comparison of PET performance across the PET-MR scanners.


  • Open Access

    Experimental validation of estimated spatially variant radioisotope-specific point spread functions using published positron range simulations and fluorine-18 measurements

    by Jose M Anton-Rodriguez, Georgios Krokos, Fotis Aristeidis Kotasidis, Marie-Claude Asselin, Olivia Morris, Peter Julyan, Anthony Archer, Julian C Matthews

    In this work we compare spatially variant radioisotope specific point spread functions (PSFs) derived from published positron range data with measured data using a High Resolution Research Tomograph (HRRT). Spatially variant PSFs were measured on a HRRT for fluorine-18, carbon-11 and gallium-68 using an array of printed point sources. For gallium-68, this required modification of the original design to handle its longer positron range. Using the fluorine-18 measurements and previously published data from Monte-Carlo simulations of positron range, estimated PSFs for carbon-11 and gallium-68 were calculated and compared with experimental data. A double 3D Gaussian function was fitted to the estimated and measured data and used to model the spatially varying PSFs over the scanner field of view (FOV). Differences between the measured and estimated PSFs were quantified using the full-width-at-half-maximum (FWHM) and full-width-at-tenth-maximum (FWTM) in the tangential, radial and axial directions. While estimated PSFs were generally in agreement with the measured PSFs over the entire FOV better agreement was observed (FWHM and FWTM differences of less than 10%) when using one of the two sets of positron range simulations, especially for gallium-68 and for the FWTM. Spatially variant radioisotope specific PSFs can be accurately estimated from fluorine-18 measurements and published positron range data. We have experimentally validated this approach for carbon-11 and gallium-68, and such an approach may be applicable to other radioisotopes such as oxygen-15 for which measurements are not practical.