A Novel Semiemperical Friction Coefficient Model Between Needle and Polyvinyl Alcohol Tissue Phantom and Its Validation by Using Computational Inverse Technique
- 7 March 2022
- journal article
- research article
- Published by ASME International in Journal of Tribology
- Vol. 144 (8) , 1-18
Abstract
Needle–tissue interactive force is vital for developing a virtual simulation and planning system (SPS) and optimizing needle control strategy, wherein the friction coefficient is an important parameter but difficult to pre-determine. The existing studies on friction coefficient estimation were lack of qualitative analysis and did not consider the effect of normal pressure and interactive velocity, which may lead to the inaccuracy of the friction calculation. In this paper, we proposed a novel semiempirical friction coefficient model based on the modified classical elastic friction theory that constructs the relationship between the friction coefficient and parameters such as the normal pressure and velocity. The proposed friction coefficient model is validated by using the computational inverse technique based on coupled finite element material point (CFEMP) contact algorithm. The results show that the friction coefficient between the needle and polyvinyl alcohol (PVA) tissue phantom varies from 0.091 to 0.242 with different normal pressure (7.95–17.80 kPa) and insertion velocity (1–9 mm/s), which agrees well with the experimental data. The results of the paper can help to better understand the intrinsic characteristics of the needle–tissue interactions and optimal needle actuation strategies.Keywords
This publication has 24 references indexed in Scilit:
- The significance of rate dependency in blade insertions into a gelatin soft tissue phantomTribology International, 2013
- Detailed finite element modelling of deep needle insertions into a soft tissue phantom using a cohesive approachComputer Methods in Biomechanics and Biomedical Engineering, 2013
- Estimation of the Cutting Force Using the Dynamic Friction Coefficient Obtained by Reaction Force During the Needle InsertionProcedia CIRP, 2013
- An adaptive finite element material point method and its application in extreme deformation problemsComputer Methods in Applied Mechanics and Engineering, 2012
- Coupling of finite element method with material point method by local multi-mesh contact methodComputer Methods in Applied Mechanics and Engineering, 2011
- Estimation of fracture toughness of liver tissue: Experiments and validationMedical Engineering & Physics, 2011
- PVA hydrogel properties for biomedical applicationJournal of the Mechanical Behavior of Biomedical Materials, 2011
- Numerical simulation of microneedles' insertion into skinComputer Methods in Biomechanics and Biomedical Engineering, 2011
- Needle insertion into soft tissue: A surveyMedical Engineering & Physics, 2006