Shilun Du
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shilun Du has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Yong Lei
State Key Lab of Fluid Power & Mechatronic Systems, Zhejiang University, HangZhou, ZheJiang, 315000, China
9 shared publications - Tian Xu
Zhejiang University
4 shared publications Tian Xu
University of Virginia The Department of Mechanical and Aerospace Engineering Within the School of Engineering and Applied Science Charlottesville, VA 22302
3 shared publicationsYingda Hu
State Key Lab of Fluid Power & Mechatronic Systems, Zhejiang University, HangZhou, ZheJiang, 315000, China
3 shared publications- Yingda Hu
Zhejiang University State Key Laboratory of Fluid Power and Mechatronic Systems, Department of Mechanical Engineering Hangzhou 310027
3 shared publications Fan Wei
State Key Lab of Fluid Power & Mechatronic Systems, Zhejiang University, HangZhou, ZheJiang, 315000, China
2 shared publications
Latest Publications
- 13 January 2026
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 277, 109241
A novel multi-field interaction cutting model for ultrasonically activated surgical devices
- 13 January 2026
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 277, 109241
A novel multi-field interaction cutting model for ultrasonically activated surgical devices
- 28 October 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (21) , 215018
Development and evaluation of a novel organ-specific biomechanics-guided contrast-enhanced CT volume synthesis model *
Objective . C ontrast- E nhanced C omputed T omography (CECT) is a critical medical imaging modality, yet acquiring and annotating such datasets remains time-consuming. Generative models show potential in augmenting datasets, but existing methods mainly focus on single-organ CECT with small deformations and struggle to generate diverse data with large deformations.We aim to propose a novel biomechanics-guided CECT volume synthesizing model for generating deformed CECT volumes, and evaluate the effectiveness of deformation-augmented CECT datasets for downstream tasks. Approach . First, we develop a biomechanics-guided deformable CECT volume synthesizing framework using deformation as input to a C onditional G enerative A dversarial N etworks, and using sequential deformations to further generate temporally consistent deformed CECT volumes. Second, we propose a module for transition region generation and contrast adjustment in CECT. Third, we trained the deformable synthesis model on liver and kidney CECT datasets and used it for dataset augmentation. The synthesized CECT volumes fidelity was verified through qualitative and quantitative tests. The augmented dataset’s effectiveness was evaluated for downstream tasks, including segmentation and multi-organ deformable image registration. Main Results . For image fidelity, the mean D ice S imilarity C oefficient (DSC) and S tructural S imilarity I ndex M easure for the synthesized CECT volumes continuity are 0.838 and 0.988, higher than the real CT volumes. Our method outperforms existing approaches in comparative experiments. The specificity and sensitivity in radiologist Turing test are 47.5 % and 48.0 % . Comparison between deformed ex vivo porcine liver CT and synthesized CECT shows the model generates realistic deformed CT. In segmentation, model on augmented datasets achieves a mean mAP@50 scores of 0.641, outperforming 0.399 without augmentation. In deformable image registration, DSC improves by 7 % as the augmented training frames increases. Significance . The proposed model can synthesize deformable CECT volumes, augmenting dataset diversity and size. The synthesized CECT volumes reveal good volume continuity and perceptual similarity to real CECT. The augmented datasets can improve the performance for downstream tasks.
- 28 October 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (21) , 215018
Development and evaluation of a novel organ-specific biomechanics-guided contrast-enhanced CT volume synthesis model *
Objective . C ontrast- E nhanced C omputed T omography (CECT) is a critical medical imaging modality, yet acquiring and annotating such datasets remains time-consuming. Generative models show potential in augmenting datasets, but existing methods mainly focus on single-organ CECT with small deformations and struggle to generate diverse data with large deformations.We aim to propose a novel biomechanics-guided CECT volume synthesizing model for generating deformed CECT volumes, and evaluate the effectiveness of deformation-augmented CECT datasets for downstream tasks. Approach . First, we develop a biomechanics-guided deformable CECT volume synthesizing framework using deformation as input to a C onditional G enerative A dversarial N etworks, and using sequential deformations to further generate temporally consistent deformed CECT volumes. Second, we propose a module for transition region generation and contrast adjustment in CECT. Third, we trained the deformable synthesis model on liver and kidney CECT datasets and used it for dataset augmentation. The synthesized CECT volumes fidelity was verified through qualitative and quantitative tests. The augmented dataset’s effectiveness was evaluated for downstream tasks, including segmentation and multi-organ deformable image registration. Main Results . For image fidelity, the mean D ice S imilarity C oefficient (DSC) and S tructural S imilarity I ndex M easure for the synthesized CECT volumes continuity are 0.838 and 0.988, higher than the real CT volumes. Our method outperforms existing approaches in comparative experiments. The specificity and sensitivity in radiologist Turing test are 47.5 % and 48.0 % . Comparison between deformed ex vivo porcine liver CT and synthesized CECT shows the model generates realistic deformed CT. In segmentation, model on augmented datasets achieves a mean mAP@50 scores of 0.641, outperforming 0.399 without augmentation. In deformable image registration, DSC improves by 7 % as the augmented training frames increases. Significance . The proposed model can synthesize deformable CECT volumes, augmenting dataset diversity and size. The synthesized CECT volumes reveal good volume continuity and perceptual similarity to real CECT. The augmented datasets can improve the performance for downstream tasks.
- 26 November 2024
- Published by ASME International in Journal of Tribology
- Vol. 147 (7) , 1-33
A Novel Friction Coefficient Model Parameters Identification Method for Needle–Tissue Insertion Procedure
In endoscopic liver vascular insertion surgeries, during the process of angiographic operation, the success of vascular staining depends on precise needle insertion control which heavily relies on experienced surgeons. Endoscopic vascular insertion surgical navigation system shows the potential to improve position precision; however, it relies on needle–tissue interaction model and parameter identification to provide essential information for improving needle insertion accuracy, in which the friction coefficient is an important parameter but difficult to determine. In this paper, a novel needle–tissue friction coefficient identification method was proposed with unknown tissue Young's modulus under endoscopic liver surgery scenarios. A modified friction coefficient model was proposed including the adhesion and elastic friction component to describe needle–tissue dynamic interaction process which can predict the friction coefficient more precisely. The proposed parameter estimation method based on the modified friction model can simultaneously estimate friction coefficient and Young's modulus. The proposed method was demonstrated by the friction coefficient measurement experiment. The results showed that the friction coefficient model prediction results agreed well with expected value. The proposed method can be applied to provide essential tissue-needle interactive information to improve needle insertion precision in endoscopic liver vascular insertion surgery scenarios.
- 26 November 2024
- Published by ASME International in Journal of Tribology
- Vol. 147 (7) , 1-33
A Novel Friction Coefficient Model Parameters Identification Method for Needle–Tissue Insertion Procedure
In endoscopic liver vascular insertion surgeries, during the process of angiographic operation, the success of vascular staining depends on precise needle insertion control which heavily relies on experienced surgeons. Endoscopic vascular insertion surgical navigation system shows the potential to improve position precision; however, it relies on needle–tissue interaction model and parameter identification to provide essential information for improving needle insertion accuracy, in which the friction coefficient is an important parameter but difficult to determine. In this paper, a novel needle–tissue friction coefficient identification method was proposed with unknown tissue Young's modulus under endoscopic liver surgery scenarios. A modified friction coefficient model was proposed including the adhesion and elastic friction component to describe needle–tissue dynamic interaction process which can predict the friction coefficient more precisely. The proposed parameter estimation method based on the modified friction model can simultaneously estimate friction coefficient and Young's modulus. The proposed method was demonstrated by the friction coefficient measurement experiment. The results showed that the friction coefficient model prediction results agreed well with expected value. The proposed method can be applied to provide essential tissue-needle interactive information to improve needle insertion precision in endoscopic liver vascular insertion surgery scenarios.
- 18 October 2023
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 243, 107858
Needle-tissue interaction model based needle path planning method
- 18 October 2023
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 243, 107858
Needle-tissue interaction model based needle path planning method
- 11 October 2023
- Published by Springer Nature
- p. 117-131
Digital Twin Model Based Robot-Assisted Needle Insertion Navigation System with Visual and Force Feedback
- 11 October 2023
- Published by Springer Nature
- p. 117-131
Digital Twin Model Based Robot-Assisted Needle Insertion Navigation System with Visual and Force Feedback
- 16 September 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 147, 106129
A novel computational fracture toughness model for soft tissue in needle insertion
- 16 September 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 147, 106129
A novel computational fracture toughness model for soft tissue in needle insertion
- 7 March 2022
- Published by ASME International in Journal of Tribology
- Vol. 144 (8) , 1-18
A Novel Semiemperical Friction Coefficient Model Between Needle and Polyvinyl Alcohol Tissue Phantom and Its Validation by Using Computational Inverse Technique
Needle–tissue interactive force is vital for developing a virtual simulation and planning system (SPS) and optimizing needle control strategy, wherein the friction coefficient is an important parameter but difficult to pre-determine. The existing studies on friction coefficient estimation were lack of qualitative analysis and did not consider the effect of normal pressure and interactive velocity, which may lead to the inaccuracy of the friction calculation. In this paper, we proposed a novel semiempirical friction coefficient model based on the modified classical elastic friction theory that constructs the relationship between the friction coefficient and parameters such as the normal pressure and velocity. The proposed friction coefficient model is validated by using the computational inverse technique based on coupled finite element material point (CFEMP) contact algorithm. The results show that the friction coefficient between the needle and polyvinyl alcohol (PVA) tissue phantom varies from 0.091 to 0.242 with different normal pressure (7.95–17.80 kPa) and insertion velocity (1–9 mm/s), which agrees well with the experimental data. The results of the paper can help to better understand the intrinsic characteristics of the needle–tissue interactions and optimal needle actuation strategies.
- 7 March 2022
- Published by ASME International in Journal of Tribology
- Vol. 144 (8) , 1-18
A Novel Semiemperical Friction Coefficient Model Between Needle and Polyvinyl Alcohol Tissue Phantom and Its Validation by Using Computational Inverse Technique
Needle–tissue interactive force is vital for developing a virtual simulation and planning system (SPS) and optimizing needle control strategy, wherein the friction coefficient is an important parameter but difficult to pre-determine. The existing studies on friction coefficient estimation were lack of qualitative analysis and did not consider the effect of normal pressure and interactive velocity, which may lead to the inaccuracy of the friction calculation. In this paper, we proposed a novel semiempirical friction coefficient model based on the modified classical elastic friction theory that constructs the relationship between the friction coefficient and parameters such as the normal pressure and velocity. The proposed friction coefficient model is validated by using the computational inverse technique based on coupled finite element material point (CFEMP) contact algorithm. The results show that the friction coefficient between the needle and polyvinyl alcohol (PVA) tissue phantom varies from 0.091 to 0.242 with different normal pressure (7.95–17.80 kPa) and insertion velocity (1–9 mm/s), which agrees well with the experimental data. The results of the paper can help to better understand the intrinsic characteristics of the needle–tissue interactions and optimal needle actuation strategies.