Modified surgical drilling protocols influence osseointegration performance and predict value of implant stability parameters during implant healing process
Authors:
- 27 January 2020
- journal article
- research article
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 24 (10) , 3445-3455
Abstract
Objective The aim of this study was to evaluate the effects of three different surgical drilling protocols on changes of implant stability parameters and osseointegration performance during the healing period in rabbit femoral condyles. Material and methods Thirty New Zealand white rabbits were used in this study. Three experimental groups according to different surgical drilling protocols (undersized, standard and oversized preparation) were designed. Measurements of implant stability parameters were performed immediately after implant insertion and then at 1, 2, 4, and 8 weeks after the operation. After the animals were sacrificed, the bone blocks with implant were prepared for histological evaluation and histomorphometric analysis. Results The results demonstrated that the ISQ values of each group increased gradually through the whole healing period, while the damping factor showed the opposite tendency. The histomorphometric analysis revealed that BIC (bone-implant contact) values gradually increased with time until 8 weeks of healing at each group. In addition, the undersized group has the highest initial BIC (25.16% ± 7.25%) and the lowest values were found in oversized group (9.13% ± 5.89%). Moreover, a higher correlation (R2 = 0. 9817) between ISQ and BIC values in oversized group and moderate correlations between DF and BIC values in undersized group (R2 = 0.823) were demonstrated. Conclusions The undersized drilling protocol group presented the highest implant stability and BIC values in the whole healing period, while the similar tendency of results was found between standard and oversized drilling protocol groups. Clinical relevance These results suggested that undersized drilling protocol is mechanically and biologically beneficial in low-density bone. The modifications of surgical drilling protocols would influence the predictive value of implant stability parameters for osseointegration performance.Keywords
This publication has 36 references indexed in Scilit:
- Effect of Drilling Dimension on Implant Placement Torque and Early Osseointegration Stages: An Experimental Study in DogsJournal of Oral and Maxillofacial Surgery, 2012
- The effect of static bone strain on implant stability and bone remodelingBone, 2011
- Influence of surgical technique, implant shape and diameter on the primary stability in cancellous boneJournal of Oral Rehabilitation, 2010
- Influence on early osseointegration of dental implants installed with two different drilling protocols: a histomorphometric study in rabbitClinical Oral Implants Research, 2010
- The role of primary stability for successful immediate loading of dental implants. A literature reviewJournal of Dentistry, 2010
- Histological, histomorphometrical, and radiological evaluation of an experimental implant design with a high insertion torqueClinical Oral Implants Research, 2010
- Improving Bioscience Research Reporting: The ARRIVE Guidelines for Reporting Animal ResearchPLOS Biology, 2010
- Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory studyClinical Oral Implants Research, 2010
- The Effects of Superficial Roughness and Design on the Primary Stability of Dental ImplantsClinical Implant Dentistry and Related Research, 2009
- Histomorphometric and fluorescence microscopic analysis of bone remodelling after installation of implants using an osteotome techniqueClinical Oral Implants Research, 2002