Histological, histomorphometrical, and radiological evaluation of an experimental implant design with a high insertion torque
- 7 July 2010
- journal article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 21 (8) , 877-884
Abstract
Objectives: The aim of this study was to compare bone behaviour around an experimental implant design with a high insertion torque with the Astra‐Tech© implant (control).Materials and methods: In ten 18‐month‐old male minipigs, the last premolars and first molars were extracted to provide space for two implants in each quadrant. A first set of 40 implants were placed 3 months after the extraction and 40 additional implants were installed another 2 months later. The animals were sacrificed 3 months after the first implant installation so that half of the implants had healed for 1 month and the other half for 3 months. Radiological evaluation was performed at baseline, 1 month, 2 months, and 3 months after implant installation. Bone defect depth and area, bone level changes, bone‐to‐implant contact density, and peri‐implant bone fraction were measured histomorphometrically.Results: Radiological analyses revealed a significantly higher bone loss around the experimental implants. Histomorphometric analyses confirmed significantly more bone loss, larger marginal bone defects, and a lower overall peri‐implant bone fraction around the experimental implants.Conclusion: The experimental implant design caused significantly more peri‐implant bone loss compared with the control implant. As strain gauge measurements indicate excessive marginal strains around the experimental implants, osseocompression might have played a role in the observed marginal bone loss. To cite this article: Duyck J, Corpas L, Vermeiren S, Ogawa T, Quirynen M, Vandamme K, Jacobs R, Naert I. Histological, histomorphometrical, and radiological evaluation of an experimental implant design with a high insertion torque. Clin. Oral Impl. Res. 21, 2010; 877–884.Keywords
This publication has 30 references indexed in Scilit:
- Assessment of bone density differences between conventional and bone-condensing techniques using dual energy x-ray absorptiometry and radiographyOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2007
- Effect of intermittent loading and surface roughness on peri‐implant bone formation in a bone chamber modelJournal of Clinical Periodontology, 2007
- Influence of forces on peri‐implant boneClinical Oral Implants Research, 2006
- Biomechanical aspects of oral implantsClinical Oral Implants Research, 2006
- No adverse effects of bone compaction on implant fixation after resorption of compacted bone in dogsActa Orthopaedica, 2005
- Role of mechanical environment and implant design on bone tissue differentiation: current knowledge and future contextsJournal of Dentistry, 2004
- De novo alveolar bone formation adjacent to endosseous implantsClinical Oral Implants Research, 2003
- Influence of the Size of the Microgap on Crestal Bone Changes Around Titanium Implants. A Histometric Evaluation of Unloaded Non‐Submerged Implants in the Canine MandibleJournal of Periodontology, 2001
- The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: an animal experimental studyClinical Oral Implants Research, 2001
- Three‐dimensional force measurements on oral implants: a methodological studyJournal of Oral Rehabilitation, 2000