The Maximum Separation Cluster Analysis Algorithm for Atom-Probe Tomography: Parameter Determination and Accuracy
- 1 August 2014
- journal article
- research article
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 20 (6) , 1662-1671
Abstract
Atom-probe tomography is a materials characterization method ideally suited for the investigation of clustering and precipitation phenomena. To distinguish the clusters from the surrounding matrix, the maximum separation algorithm is widely employed. However, the results of the cluster analysis strongly depend on the parameters used in the algorithm and hence, a wrong choice of parameters leads to erroneous results, e.g., for the cluster number density, concentration, and size. Here, a new method to determine the optimum value of the parameter d max is proposed, which relies only on information contained in the measured atom-probe data set. Atom-probe simulations are employed to verify the method and to determine the sensitivity of the maximum separation algorithm to other input parameters. In addition, simulations are used to assess the accuracy of cluster analysis in the presence of trajectory aberrations caused by the local magnification effect. In the case of Cu-rich precipitates (Cu concentration 40–60 at% and radius 0.25–1.0 nm) in a bcc Fe–Si–Cu matrix, it is shown that the error in concentration is below 10 at% and the error in radius is <0.15 nm for all simulated conditions, provided that the correct value for d max, as determined with the newly proposed method, is employed.Keywords
This publication has 30 references indexed in Scilit:
- Atom probe study of Cu2ZnSnSe4 thin-films prepared by co-evaporation and post-deposition annealingApplied Physics Letters, 2013
- Application of Delaunay tessellation for the characterization of solute-rich clusters in atom probe tomographyUltramicroscopy, 2011
- On the Field Evaporation Behavior of Dielectric Materials in Three-Dimensional Atom Probe: A Numeric SimulationMicroscopy and Microanalysis, 2010
- Clustering and nearest neighbour distances in atom probe tomography: the influence of the interfacesJournal of Microscopy, 2010
- New Techniques for the Analysis of Fine-Scaled Clustering Phenomena within Atom Probe Tomography (APT) DataMicroscopy and Microanalysis, 2007
- Characterization of precipitates in MA/ODS ferritic alloysJournal of Nuclear Materials, 2006
- TEM and 3DAP characterization of an age-hardened Mg–Ca–Zn alloyScripta Materialia, 2005
- Investigation of the early stages of decomposition of Cu–0.7at.% Fe with the tomographic atom probeMaterials Science and Engineering: A, 2003
- An Analysis of the Structure of Irradiation induced Cu-enriched Clusters in Low and High Nickel WeldsMRS Proceedings, 2000
- A general protocol for the reconstruction of 3D atom probe dataApplied Surface Science, 1995