Cascaded H-bridge multilevel inverter (CHB-MLI)-based shunt active power filter (SAPF) is one of the finest solutions for power quality improvement in case of medium-voltage distribution sector. Performance of SAPF degrades due to the presence of DC offset and harmonics in the grid voltage since this will result phase angle and frequency error. Therefore, modified single-phase synchronous reference frame theory comprising of advanced PLL is presented in this article. The advanced PLL can track frequency and phase angle accurately even though source voltage is having DCor harmonic content. A detailed mathematical modeling and stability analysis of this PLL is presented using Routh-Hurwitz criteria. A novel systematic design procedure using gravitational search algorithm (GSA) and an Eigen value analysis is proposed for calculating optimal PLL parameters. Closed-loop SAPF control stability is tested using root-locus analysis. An extensive experimental analysis of the proposed control applied to CHB-MLI-based SAPF has been performed under distorted source voltage and non-linear loading conditions to show the effectiveness of the proposed control over recently published work. Source current maintains its sinusoidal shape, properly synchronized with grid voltage and having distortion limit in compliance with IEEE-519 standard irrespective of source voltage conditions during the operation of SAPF.Keywords
This publication has 11 references indexed in Scilit:
- Design of a fast response time single-phase PLL with dc offset rejection capabilityElectric Power Systems Research, 2017
- A Comprehensive Review on Cascaded H-bridge Inverter-Based Large-Scale Grid-Connected PhotovoltaicIETE Technical Review, 2016
- Topological aspects of power quality improvement techniques: A comprehensive overviewRenewable and Sustainable Energy Reviews, 2016
- A critical review of detection and classification of power quality eventsRenewable and Sustainable Energy Reviews, 2015
- Proportional–integral/proportional–integral‐derivative tuning procedure of a single‐phase shunt active power filter using Bode diagramIET Power Electronics, 2014
- Single‐phase phase locked loop with DC offset and noise rejection for photovoltaic invertersIET Power Electronics, 2014
- Real-time implementation of PI and fuzzy logic controllers based shunt active filter control strategies for power quality improvementInternational Journal of Electrical Power & Energy Systems, 2012
- A Digital Signal Processor Based Performance Evaluation of Three-phase Four-wire Shunt Active Filter for Harmonic Elimination, Reactive Power Compensation, and Balancing of Non-linear Loads under Non-ideal Mains VoltagesElectric Power Components and Systems, 2012
- A Novel Reference Signal Generation Method for Power-Quality Improvement of Unified Power-Quality ConditionerIEEE Transactions on Power Delivery, 2011
- Placement of power quality monitors using enhanced genetic algorithm and wavelet transformIET Generation, Transmission & Distribution, 2011