Soumyadeep Ray
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Soumyadeep Ray has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Nitin Gupta
MNIT
9 shared publications R. A. Gupta
MNIT Jaipur
5 shared publicationsRam Avtar Gupta
Department of Electrical Engineering, MNIT Jaipur, Rajasthan, India
4 shared publicationsNitin Gupta
Department of Electrical Engineering; Malaviya National Institute of Technology Jaipur; Jaipur India
3 shared publications- Abhijit Dasgupta
School of Electrical Engineering, KIIT University, Bhubaneswar
2 shared publications Niharika Gotherwal
Department of Electrical Engineering, MNIT Jaipur, India, 302017
2 shared publications
Latest Publications
- 7 February 2019
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 47 (3) , 230-247
Mathematical and Experimental Investigation on Advanced PLL for Cascaded H-Bridge Multilevel Inverter in Active Filtering Application
Cascaded H-bridge multilevel inverter (CHB-MLI)-based shunt active power filter (SAPF) is one of the finest solutions for power quality improvement in case of medium-voltage distribution sector. Performance of SAPF degrades due to the presence of DC offset and harmonics in the grid voltage since this will result phase angle and frequency error. Therefore, modified single-phase synchronous reference frame theory comprising of advanced PLL is presented in this article. The advanced PLL can track frequency and phase angle accurately even though source voltage is having DCor harmonic content. A detailed mathematical modeling and stability analysis of this PLL is presented using Routh-Hurwitz criteria. A novel systematic design procedure using gravitational search algorithm (GSA) and an Eigen value analysis is proposed for calculating optimal PLL parameters. Closed-loop SAPF control stability is tested using root-locus analysis. An extensive experimental analysis of the proposed control applied to CHB-MLI-based SAPF has been performed under distorted source voltage and non-linear loading conditions to show the effectiveness of the proposed control over recently published work. Source current maintains its sinusoidal shape, properly synchronized with grid voltage and having distortion limit in compliance with IEEE-519 standard irrespective of source voltage conditions during the operation of SAPF.
- 7 February 2019
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 47 (3) , 230-247
Mathematical and Experimental Investigation on Advanced PLL for Cascaded H-Bridge Multilevel Inverter in Active Filtering Application
Cascaded H-bridge multilevel inverter (CHB-MLI)-based shunt active power filter (SAPF) is one of the finest solutions for power quality improvement in case of medium-voltage distribution sector. Performance of SAPF degrades due to the presence of DC offset and harmonics in the grid voltage since this will result phase angle and frequency error. Therefore, modified single-phase synchronous reference frame theory comprising of advanced PLL is presented in this article. The advanced PLL can track frequency and phase angle accurately even though source voltage is having DCor harmonic content. A detailed mathematical modeling and stability analysis of this PLL is presented using Routh-Hurwitz criteria. A novel systematic design procedure using gravitational search algorithm (GSA) and an Eigen value analysis is proposed for calculating optimal PLL parameters. Closed-loop SAPF control stability is tested using root-locus analysis. An extensive experimental analysis of the proposed control applied to CHB-MLI-based SAPF has been performed under distorted source voltage and non-linear loading conditions to show the effectiveness of the proposed control over recently published work. Source current maintains its sinusoidal shape, properly synchronized with grid voltage and having distortion limit in compliance with IEEE-519 standard irrespective of source voltage conditions during the operation of SAPF.
- 14 December 2018
- Published by Springer Nature
- p. 547-558
Modified Three-Layered Artificial Neural Network-Based Improved Control of Multilevel Inverters for Active Filtering
- 14 December 2018
- Published by Springer Nature
- p. 547-558
Modified Three-Layered Artificial Neural Network-Based Improved Control of Multilevel Inverters for Active Filtering
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Improved single phase SRF algorithm for CHB inverter based shunt active power filter under non-ideal supply conditions
This paper presents five-level cascaded H-bridge multilevel inverter based shunt active power filter for medium voltage and high power distribution system. An improved single-phase synchronous reference frame theory based control algorithm is proposed in this paper for solving current related power quality problems. This control is well capable of improving power factor and maintaining better voltage regulation in the distribution sector. This proposed control is a complete solution in case of balanced and/or unbalanced loading condition in existing distribution system. This control algorithm is equally effective in case of distorted and/or unbalanced supply voltage condition. The proposed system is designed in Simulink platform of MATLAB software. The effectiveness of the proposed algorithm is tested in different possible conditions. Test results suggest its effectiveness over conventional control algorithms.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Improved single phase SRF algorithm for CHB inverter based shunt active power filter under non-ideal supply conditions
This paper presents five-level cascaded H-bridge multilevel inverter based shunt active power filter for medium voltage and high power distribution system. An improved single-phase synchronous reference frame theory based control algorithm is proposed in this paper for solving current related power quality problems. This control is well capable of improving power factor and maintaining better voltage regulation in the distribution sector. This proposed control is a complete solution in case of balanced and/or unbalanced loading condition in existing distribution system. This control algorithm is equally effective in case of distorted and/or unbalanced supply voltage condition. The proposed system is designed in Simulink platform of MATLAB software. The effectiveness of the proposed algorithm is tested in different possible conditions. Test results suggest its effectiveness over conventional control algorithms.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 291-296
Advanced PWM for balancing DC-link voltages in seven-level CHB inverter based active filter
DC-link voltage balancing among different capacitors is a serious issue in case of multilevel inverter based shunt active power filter in medium-voltage and high-power distribution sector. Therefore, this paper presents an advanced pulse width modulation (PWM) technique for seven-level cascaded H-bridge inverter in order to maintain voltage balance among different dc-links. This modulation method is well capable of balanced charging and discharging of dc-link voltages without increasing circuit complexity. This method also can be well applicable when number of H-Bridges changes. This modulation technique is very effective in terms of voltage balancing as well as for maintaining voltage output THD at lower level. The proposed modulation technique along with synchronous reference frame theory is used in shunt type active power filtering application and found very effective during the operation of transient and steady-state condition. The proposed system is implemented in Simulink platform of MALTAB software and performance shows its effectiveness over conventional PWM techniques used for cascaded inverters.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 291-296
Advanced PWM for balancing DC-link voltages in seven-level CHB inverter based active filter
DC-link voltage balancing among different capacitors is a serious issue in case of multilevel inverter based shunt active power filter in medium-voltage and high-power distribution sector. Therefore, this paper presents an advanced pulse width modulation (PWM) technique for seven-level cascaded H-bridge inverter in order to maintain voltage balance among different dc-links. This modulation method is well capable of balanced charging and discharging of dc-link voltages without increasing circuit complexity. This method also can be well applicable when number of H-Bridges changes. This modulation technique is very effective in terms of voltage balancing as well as for maintaining voltage output THD at lower level. The proposed modulation technique along with synchronous reference frame theory is used in shunt type active power filtering application and found very effective during the operation of transient and steady-state condition. The proposed system is implemented in Simulink platform of MALTAB software and performance shows its effectiveness over conventional PWM techniques used for cascaded inverters.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 572-577
Active and reactive power management of photovoltaic fed CHB inverter based active filter with improved control under normal/distorted supply
This paper proposes Cascaded H-bridge (CHB) inverter based shunt type active filtering scheme with PV arrays as a source for medium-voltage, high-power distribution system with modified control strategy which can work under normal/distorted supply conditions. This module can minimize reactive power burden as well as maintain unity power factor operation of the distribution grid during night time and can supply active and reactive power in day time with proposed modified control strategy. Self-charging algorithm is used as a DC voltage controller for faster dynamic response and enhanced phase-locked loop (EPLL) is used for synchronizing this module with grid, which can restrict harmonic content propagation into the control algorithm in distorted supply condition. PV array with boost converter is used as a DC voltage source of each H-Bridge, where perturb and observe (P and O) MPPT algorithm decides the switching pattern of boost converter for improving efficiency of the proposed system. A detailed simulated study of proposed topology is conducted in MATLAB/Simulink. This scheme with modified control algorithm is rigorously tested in different linear/non-linear loading conditions as well as with different irradiations and normal/distorted supply conditions. Transient and steady-state behavior of the proposed system decides effectiveness of the projected scheme under distorted supply voltage conditions.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 572-577
Active and reactive power management of photovoltaic fed CHB inverter based active filter with improved control under normal/distorted supply
This paper proposes Cascaded H-bridge (CHB) inverter based shunt type active filtering scheme with PV arrays as a source for medium-voltage, high-power distribution system with modified control strategy which can work under normal/distorted supply conditions. This module can minimize reactive power burden as well as maintain unity power factor operation of the distribution grid during night time and can supply active and reactive power in day time with proposed modified control strategy. Self-charging algorithm is used as a DC voltage controller for faster dynamic response and enhanced phase-locked loop (EPLL) is used for synchronizing this module with grid, which can restrict harmonic content propagation into the control algorithm in distorted supply condition. PV array with boost converter is used as a DC voltage source of each H-Bridge, where perturb and observe (P and O) MPPT algorithm decides the switching pattern of boost converter for improving efficiency of the proposed system. A detailed simulated study of proposed topology is conducted in MATLAB/Simulink. This scheme with modified control algorithm is rigorously tested in different linear/non-linear loading conditions as well as with different irradiations and normal/distorted supply conditions. Transient and steady-state behavior of the proposed system decides effectiveness of the projected scheme under distorted supply voltage conditions.
- 1 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Comparative analysis of conventional and modified peak-detection based control technique for cascaded H-bridge multilevel inverter based shunt active power filter
This paper presents a modified peak-detection algorithm based control theory for three-phase, three-wire (3P-3W) Shunt Active Power Filter (SAPF) where Cascaded H-Bridge Multilevel Inverter (CHB-MLI) is used as a voltage source inverter (VSI) unit for reactive power compensation, power factor correction and harmonic mitigation in medium-voltage and high-power distribution system. The proposed control theory is implemented in MATLAB/Simulink platform and a rigorous comparative analysis is done with well known p-q theory and synchronous reference frame (SRF) theory to prove its effectiveness. Comparative study shows that modified control algorithm gives better transient performance in terms of settling time and peak overshoot.
- 1 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Comparative analysis of conventional and modified peak-detection based control technique for cascaded H-bridge multilevel inverter based shunt active power filter
This paper presents a modified peak-detection algorithm based control theory for three-phase, three-wire (3P-3W) Shunt Active Power Filter (SAPF) where Cascaded H-Bridge Multilevel Inverter (CHB-MLI) is used as a voltage source inverter (VSI) unit for reactive power compensation, power factor correction and harmonic mitigation in medium-voltage and high-power distribution system. The proposed control theory is implemented in MATLAB/Simulink platform and a rigorous comparative analysis is done with well known p-q theory and synchronous reference frame (SRF) theory to prove its effectiveness. Comparative study shows that modified control algorithm gives better transient performance in terms of settling time and peak overshoot.
- 1 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Performance comparison of reference current extraction techniques for indirect current control based shunt active filter
The shunt active filters play a dominant role for eradication of power quality problems in modern era, where the majority of load has non-linear nature. It is very important for an active filter to acquire accurate reference current extraction technique as the inaccuracy leads to incorrect compensation and lost control over the DC link. In this paper, three significantapproachesnamely the instantaneous power theory (IPT), unit vector control (UVT) and synchronous reference frame theory (SRF) for reference current extraction have been assessed, evaluated and compared. Thesecontrol schemes are based on indirect current control technique (ICC) and in all methods PI controller is used for stabilization of the DC-link voltage. The advantages and limitations of reference current extraction methods found in literature have been also discussed and justified on the basis of MATLAB simulations for current source type of load, voltage source type of load and transient load conditions.
- 1 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Performance comparison of reference current extraction techniques for indirect current control based shunt active filter
The shunt active filters play a dominant role for eradication of power quality problems in modern era, where the majority of load has non-linear nature. It is very important for an active filter to acquire accurate reference current extraction technique as the inaccuracy leads to incorrect compensation and lost control over the DC link. In this paper, three significantapproachesnamely the instantaneous power theory (IPT), unit vector control (UVT) and synchronous reference frame theory (SRF) for reference current extraction have been assessed, evaluated and compared. Thesecontrol schemes are based on indirect current control technique (ICC) and in all methods PI controller is used for stabilization of the DC-link voltage. The advantages and limitations of reference current extraction methods found in literature have been also discussed and justified on the basis of MATLAB simulations for current source type of load, voltage source type of load and transient load conditions.
- 2 August 2016
- Published by Taylor & Francis in IETE Technical Review
- Vol. 34 (5) , 463-477
A Comprehensive Review on Cascaded H-bridge Inverter-Based Large-Scale Grid-Connected Photovoltaic
- 2 August 2016
- Published by Taylor & Francis in IETE Technical Review
- Vol. 34 (5) , 463-477
A Comprehensive Review on Cascaded H-bridge Inverter-Based Large-Scale Grid-Connected Photovoltaic