Is there a difference in bleeding after left ventricular assist device implant: centrifugal versus axial?
Open Access
- 13 February 2018
- journal article
- research article
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 13 (1) , 1-6
Abstract
Continuous-flow left ventricular assist devices (CF-LVAD) have become the standard of care for patients with end stage heart failure. Device reliability has increased, bringing the potential for VAD, compared to transplant, into debate. However, complications continue to limit VADs as first line therapy. Bleeding is a major morbidity. A debate exists as to the difference in bleeding profile between the major centrifugal and axial flow devices. We hypothesized that there would be similar adverse bleeding event profiles between the 2 major CF-LVADs. We retrospectively investigated isolated CF LVADs performed at our institution between July 2010 and July 2015: HeartMateII (HMII, n = 105) and HeartWare (HVAD, n = 34). We reviewed demographic, perioperative and short- and long-term outcomes. There was no significant difference in demographics or comorbidities. There was a low incidence of gastrointestinal (GI) bleed 3.9% in HMII and 2.9% in HVAD (p = 0.78). Preoperatively, the cohorts did not differ in coagulation measures (p = 0.95). Within the post-operative period, there was no difference in product transfusion: red blood cells (p = 0.10), fresh frozen plasma (p = 0.19), and platelets (p = 0.89). Post-operatively, a higher but not significantly different number of HMII patients returned to the operating room for bleeding (n = 27) compared to HVAD (n = 6, p = 0.35). There was no difference in rates of stroke (p = 0.65), re-intubation (p = 0.60), driveline infection (p = 0.05), and GI bleeding (p = 0.31). The patients had equivalent ICU LOS (p = 0.86) and index hospitalization LOS (p = 0.59). We found no difference in the rate of bleeding complications between the current commercially available axial and centrifugal flow devices.Keywords
This publication has 22 references indexed in Scilit:
- Temporal Differences in Causes of Mortality After Left Ventricular Assist Device ImplantationThe Annals of Thoracic Surgery, 2015
- 5 Risk for Bleeding after MCSD Implant: An Analysis of 2358 Patients in INTERMACSThe Journal of Heart and Lung Transplantation, 2011
- Acquired von Willebrand Syndrome After Continuous-Flow Mechanical Device Support Contributes to a High Prevalence of Bleeding During Long-Term Support and at the Time of TransplantationJACC, 2010
- Increased Incidence of Gastrointestinal Bleeding Following Implantation of the HeartMate II LVADJournal of Cardiac Surgery, 2010
- Advanced Heart Failure Treated with Continuous-Flow Left Ventricular Assist DeviceThe New England journal of medicine, 2009
- Impact of Left Ventricular Assist Device Bridging on Posttransplant OutcomesThe Annals of Thoracic Surgery, 2009
- Incidence and Patterns of Adverse Event Onset During the First 60 Days After Ventricular Assist Device ImplantationThe Annals of Thoracic Surgery, 2009
- Extended Mechanical Circulatory Support With a Continuous-Flow Rotary Left Ventricular Assist DeviceJACC, 2009
- Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devicesThe Journal of Thoracic and Cardiovascular Surgery, 2009
- Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease☆European Journal of Cardio-Thoracic Surgery, 2008