Carol W. Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Carol W. Chen has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Ann C. Gaffey
Department of Surgery, Hospital of the University of Pennsylvania, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
1 shared publication - Christian A. Bermudez
Division of Cardiovascular Surgery, University of Pennsylvania Health System, Philadelphia, Pa
1 shared publication - Jason J. Han
Division of Cardiac Surgery, Department of Surgery, Cooper University Hospital, Camden, USA
1 shared publication - Jennifer J. Chung
Division of Cardiovascular Surgery, Department of Surgery, Perelman School of Medicine, University of Pennsylvania, Silverstein 6, 3400 Spruce St, Philadelphia, PA, 19104, USA
1 shared publication - Joyce Wald
Division of Cardiovascular Medicine, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
1 shared publication - Pavan Atluri
Department of Cardiac Surgery Thomas Jefferson University Philadelphia Pennsylvania USA
1 shared publication
Latest Publications
- Open Access
- 13 February 2018
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 13 (1) , 1-6
Is there a difference in bleeding after left ventricular assist device implant: centrifugal versus axial?
Continuous-flow left ventricular assist devices (CF-LVAD) have become the standard of care for patients with end stage heart failure. Device reliability has increased, bringing the potential for VAD, compared to transplant, into debate. However, complications continue to limit VADs as first line therapy. Bleeding is a major morbidity. A debate exists as to the difference in bleeding profile between the major centrifugal and axial flow devices. We hypothesized that there would be similar adverse bleeding event profiles between the 2 major CF-LVADs. We retrospectively investigated isolated CF LVADs performed at our institution between July 2010 and July 2015: HeartMateII (HMII, n = 105) and HeartWare (HVAD, n = 34). We reviewed demographic, perioperative and short- and long-term outcomes. There was no significant difference in demographics or comorbidities. There was a low incidence of gastrointestinal (GI) bleed 3.9% in HMII and 2.9% in HVAD (p = 0.78). Preoperatively, the cohorts did not differ in coagulation measures (p = 0.95). Within the post-operative period, there was no difference in product transfusion: red blood cells (p = 0.10), fresh frozen plasma (p = 0.19), and platelets (p = 0.89). Post-operatively, a higher but not significantly different number of HMII patients returned to the operating room for bleeding (n = 27) compared to HVAD (n = 6, p = 0.35). There was no difference in rates of stroke (p = 0.65), re-intubation (p = 0.60), driveline infection (p = 0.05), and GI bleeding (p = 0.31). The patients had equivalent ICU LOS (p = 0.86) and index hospitalization LOS (p = 0.59). We found no difference in the rate of bleeding complications between the current commercially available axial and centrifugal flow devices.
- 13 February 2018
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 13 (1) , 1-6
Open AccessIs there a difference in bleeding after left ventricular assist device implant: centrifugal versus axial?
Continuous-flow left ventricular assist devices (CF-LVAD) have become the standard of care for patients with end stage heart failure. Device reliability has increased, bringing the potential for VAD, compared to transplant, into debate. However, complications continue to limit VADs as first line therapy. Bleeding is a major morbidity. A debate exists as to the difference in bleeding profile between the major centrifugal and axial flow devices. We hypothesized that there would be similar adverse bleeding event profiles between the 2 major CF-LVADs. We retrospectively investigated isolated CF LVADs performed at our institution between July 2010 and July 2015: HeartMateII (HMII, n = 105) and HeartWare (HVAD, n = 34). We reviewed demographic, perioperative and short- and long-term outcomes. There was no significant difference in demographics or comorbidities. There was a low incidence of gastrointestinal (GI) bleed 3.9% in HMII and 2.9% in HVAD (p = 0.78). Preoperatively, the cohorts did not differ in coagulation measures (p = 0.95). Within the post-operative period, there was no difference in product transfusion: red blood cells (p = 0.10), fresh frozen plasma (p = 0.19), and platelets (p = 0.89). Post-operatively, a higher but not significantly different number of HMII patients returned to the operating room for bleeding (n = 27) compared to HVAD (n = 6, p = 0.35). There was no difference in rates of stroke (p = 0.65), re-intubation (p = 0.60), driveline infection (p = 0.05), and GI bleeding (p = 0.31). The patients had equivalent ICU LOS (p = 0.86) and index hospitalization LOS (p = 0.59). We found no difference in the rate of bleeding complications between the current commercially available axial and centrifugal flow devices.