Abstract
Objective: To investigate the frequency and distribution of B‐, I‐, and Z‐lines in clinically healthy cats and to determine whether there is a difference in frequency and distribution between two different lung ultrasound protocols.Design: Prospective cross‐sectional study from June to September 2022.Setting: Companion animal referral hospital.Animals: Sixty‐four cats determined to be healthy based on history and physical examination.Interventions: All cats had point‐of‐care lung ultrasound performed with frequency of B‐, I‐, and Z‐lines recorded. Findings of a modified Calgary pleura and lung ultrasound (PLUS) protocol (19 sites recorded) and a veterinary Brief Lung Ultrasound Exam (VetBLUE) protocol (nine sites), both including the subxiphoid site, were compared.Measurements and Main Results: B‐lines were identified in 14%–27% of cats depending on the protocol used, with a median of 95% of clinically healthy cats regardless of protocol used. B‐lines were rarely detected at the subxiphoid view. A significant difference between protocols was found when comparing the percentage of cats with B‐ and I‐lines.

This publication has 33 references indexed in Scilit: