Hugo K. J. Swanstein
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hugo K. J. Swanstein has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Kris Gommeren
Department of Companion Animal Clinical Sciences University of Liege Liege Belgium
2 shared publications- Soren R. Boysen
Faculty of Veterinary Medicine, University of Calgary, Calgary, Canada
2 shared publications A. V. Müller
Department of Veterinary Clinical Sciences, University Hospital for Companion Animals University of Copenhagen Frederiksberg Denmark
1 shared publicationJ. L. Willesen
Department of Veterinary Clinical Sciences, University Hospital for Companion Animals University of Copenhagen Frederiksberg Denmark
1 shared publication- Laura Cole
Department of Clinical Science and Services Royal Veterinary College Hatfield UK
1 shared publication Rebecca Langhorn
Department of Veterinary Clinical Sciences University of Copenhagen Frederiksberg Denmark
1 shared publication
Latest Publications
- 25 May 2026
- Published by Wiley in Journal of Veterinary Emergency and Critical Care
- Vol. 36 (3) , 384-390
Point‐of‐Care Ultrasound and Clinical Findings in 14 Cats With High‐Rise Syndrome
Objective: To describe point‐of‐care ultrasound (POCUS) and clinical findings in cats with high‐rise syndrome. Design: Retrospective descriptive study. Setting: University hospital. Animals: Fourteen cats that fell from a height. Measurements and Main Results: Data were normally distributed and are reported as mean (±SD). Cats fell from 1–9 stories. Mean respiratory rate was 53 (±23)/min; two of 14 cats were in respiratory distress. Mean animal trauma triage score was 2 (±2). Twelve cats survived to discharge, and two were euthanized due to a poor prognosis or financial constraints. POCUS included abdominal POCUS and pleural and lung ultrasound (PLUS) examinations. Abdominal POCUS was unremarkable in all cats. PLUS diagnosed pneumothorax in five of 14 cats (three unilateral, two bilateral) based on loss of lung sliding (5/5), presence of lung point (5/5), and presence of asynchronous curtain signs (2/5). The two cats in respiratory distress presented with bilateral pneumothorax and asynchronous curtain signs. PLUS identified coalescent B‐lines in six cats and ventral lung consolidation in one. A combination of limb ( n = 7), abdominal ( n = 5), and thoracic ( n = 9) radiographs were obtained. Abdominal radiographs were unremarkable. Limb and pelvic radiographs identified fractures in six cats (femoral, spinal, tibial, or pelvic). Thoracic radiographs identified three cats with pneumothorax and two with pulmonary contusions. Of the five cats that had pneumothorax identified on PLUS, three had pneumothorax identified on thoracic radiographs. Of the five cats with coalescent B‐lines seen on PLUS, three had unremarkable thoracic radiographs, and two had findings consistent with pulmonary contusions. Conclusions: This study describes POCUS and clinical findings in cats with high‐rise syndrome and reports absent lung sliding in combination with lung point or asynchronous curtain signs to ultrasonographically support a diagnosis of pneumothorax. Thoracic radiographs failed to detect several abnormalities that were identified with PLUS.
- 25 May 2026
- Published by Wiley in Journal of Veterinary Emergency and Critical Care
- Vol. 36 (3) , 384-390
Point‐of‐Care Ultrasound and Clinical Findings in 14 Cats With High‐Rise Syndrome
Objective: To describe point‐of‐care ultrasound (POCUS) and clinical findings in cats with high‐rise syndrome. Design: Retrospective descriptive study. Setting: University hospital. Animals: Fourteen cats that fell from a height. Measurements and Main Results: Data were normally distributed and are reported as mean (±SD). Cats fell from 1–9 stories. Mean respiratory rate was 53 (±23)/min; two of 14 cats were in respiratory distress. Mean animal trauma triage score was 2 (±2). Twelve cats survived to discharge, and two were euthanized due to a poor prognosis or financial constraints. POCUS included abdominal POCUS and pleural and lung ultrasound (PLUS) examinations. Abdominal POCUS was unremarkable in all cats. PLUS diagnosed pneumothorax in five of 14 cats (three unilateral, two bilateral) based on loss of lung sliding (5/5), presence of lung point (5/5), and presence of asynchronous curtain signs (2/5). The two cats in respiratory distress presented with bilateral pneumothorax and asynchronous curtain signs. PLUS identified coalescent B‐lines in six cats and ventral lung consolidation in one. A combination of limb ( n = 7), abdominal ( n = 5), and thoracic ( n = 9) radiographs were obtained. Abdominal radiographs were unremarkable. Limb and pelvic radiographs identified fractures in six cats (femoral, spinal, tibial, or pelvic). Thoracic radiographs identified three cats with pneumothorax and two with pulmonary contusions. Of the five cats that had pneumothorax identified on PLUS, three had pneumothorax identified on thoracic radiographs. Of the five cats with coalescent B‐lines seen on PLUS, three had unremarkable thoracic radiographs, and two had findings consistent with pulmonary contusions. Conclusions: This study describes POCUS and clinical findings in cats with high‐rise syndrome and reports absent lung sliding in combination with lung point or asynchronous curtain signs to ultrasonographically support a diagnosis of pneumothorax. Thoracic radiographs failed to detect several abnormalities that were identified with PLUS.
- 17 October 2025
- Published by Wiley in Journal of Small Animal Practice
- Vol. 67 (2) , 186-190
Monitoring a severe Aelurostrongylus abstrusus infection in a kitten with point‐of‐care ultrasound and radiography
A 4‐month‐old male intact domestic shorthair kitten was referred due to acute onset of severe respiratory distress. Aelurostrongylus abstrusus infection was diagnosed by Baermann technique. The kitten showed a fluctuating respiratory status despite anthelmintic and supportive therapy; severe initial distress followed by partial improvement, deterioration by Day 33 and marked recovery by Day 63. Monitoring included clinical examinations, oxygen saturation, faecal analysis, thoracic radiography and lung point‐of‐care ultrasound on Days 1, 10, 33 and 63. Lung ultrasound and thoracic radiographs consistently revealed diffusely distributed pulmonary disease and pleural involvement. Several pathological lung ultrasound features were identified, such as increased B‐lines, subpleural nodules, lung consolidations with and without air‐bronchograms, vascular sign and pleural line irregularity. This is the first report comparing lung ultrasound and thoracic radiography in a kitten with Aelurostrongylus abstrusus .
- 17 October 2025
- Published by Wiley in Journal of Small Animal Practice
- Vol. 67 (2) , 186-190
Monitoring a severe Aelurostrongylus abstrusus infection in a kitten with point‐of‐care ultrasound and radiography
A 4‐month‐old male intact domestic shorthair kitten was referred due to acute onset of severe respiratory distress. Aelurostrongylus abstrusus infection was diagnosed by Baermann technique. The kitten showed a fluctuating respiratory status despite anthelmintic and supportive therapy; severe initial distress followed by partial improvement, deterioration by Day 33 and marked recovery by Day 63. Monitoring included clinical examinations, oxygen saturation, faecal analysis, thoracic radiography and lung point‐of‐care ultrasound on Days 1, 10, 33 and 63. Lung ultrasound and thoracic radiographs consistently revealed diffusely distributed pulmonary disease and pleural involvement. Several pathological lung ultrasound features were identified, such as increased B‐lines, subpleural nodules, lung consolidations with and without air‐bronchograms, vascular sign and pleural line irregularity. This is the first report comparing lung ultrasound and thoracic radiography in a kitten with Aelurostrongylus abstrusus .
- 1 July 2025
- Published by Wiley in Journal of Veterinary Emergency and Critical Care
- Vol. 35 (4) , 368-377
Comparison of Two Lung Ultrasound Protocols for Identification and Distribution of B‐, I‐, and Z‐Lines in Clinically Healthy Cats
Objective: To investigate the frequency and distribution of B‐, I‐, and Z‐lines in clinically healthy cats and to determine whether there is a difference in frequency and distribution between two different lung ultrasound protocols.Design: Prospective cross‐sectional study from June to September 2022.Setting: Companion animal referral hospital.Animals: Sixty‐four cats determined to be healthy based on history and physical examination.Interventions: All cats had point‐of‐care lung ultrasound performed with frequency of B‐, I‐, and Z‐lines recorded. Findings of a modified Calgary pleura and lung ultrasound (PLUS) protocol (19 sites recorded) and a veterinary Brief Lung Ultrasound Exam (VetBLUE) protocol (nine sites), both including the subxiphoid site, were compared.Measurements and Main Results: B‐lines were identified in 14%–27% of cats depending on the protocol used, with a median of 95% of clinically healthy cats regardless of protocol used. B‐lines were rarely detected at the subxiphoid view. A significant difference between protocols was found when comparing the percentage of cats with B‐ and I‐lines.
- 1 July 2025
- Published by Wiley in Journal of Veterinary Emergency and Critical Care
- Vol. 35 (4) , 368-377
Comparison of Two Lung Ultrasound Protocols for Identification and Distribution of B‐, I‐, and Z‐Lines in Clinically Healthy Cats
Objective: To investigate the frequency and distribution of B‐, I‐, and Z‐lines in clinically healthy cats and to determine whether there is a difference in frequency and distribution between two different lung ultrasound protocols.Design: Prospective cross‐sectional study from June to September 2022.Setting: Companion animal referral hospital.Animals: Sixty‐four cats determined to be healthy based on history and physical examination.Interventions: All cats had point‐of‐care lung ultrasound performed with frequency of B‐, I‐, and Z‐lines recorded. Findings of a modified Calgary pleura and lung ultrasound (PLUS) protocol (19 sites recorded) and a veterinary Brief Lung Ultrasound Exam (VetBLUE) protocol (nine sites), both including the subxiphoid site, were compared.Measurements and Main Results: B‐lines were identified in 14%–27% of cats depending on the protocol used, with a median of 95% of clinically healthy cats regardless of protocol used. B‐lines were rarely detected at the subxiphoid view. A significant difference between protocols was found when comparing the percentage of cats with B‐ and I‐lines.
- Open Access
- 10 September 2024
- Published by SAGE Publications in Journal of Feline Medicine and Surgery
- Vol. 26 (9)
Feline friendly POCUS: how to implement it into your daily practice
Practical relevance: Cats are great pretenders; they often hide illness until they are critical. This makes patients of this species challenging to assess and manage in the emergency setting where quick and stress-free diagnosis and treatment are necessary. Veterinary point-of-care ultrasound (POCUS) is a rapid, evidence-based, non-invasive, repeatable, cage-side ultrasonographic examination designed to answer clinically driven questions without compromising feline wellbeing. Integrating feline friendly POCUS as an extension of the physical examination to streamline diagnostic and therapeutic interventions, thereby limiting stress and improving overall patient care, is advocated by the authors of this article. Equipment: Given the multitude of ultrasound machines and probes available that are portable, meaning they can be moved around the clinic and used patient-side, it should be possible for most practitioners to integrate POCUS into daily practice. The authors’ preferred equipment for feline POCUS is a microconvex probe and a portable machine with a fixed pre-set. This set-up allows the clinician to complete all POCUS (abdominal, lung and pleural space, and heart) without needing to move the patient, change probes or restrain the patient in a particular position, ultimately saving time, personnel and cost while maintaining patient comfort and safety. Aim: This review aims to serve as a valuable resource for veterinarians seeking to improve their feline patient care through the judicious utilisation of POCUS. In this article, the complex challenges posed by cats are addressed, and the different POCUS techniques, applications and clinical recommendations are discussed. Evidence base: This review draws on the published literature, as well as the authors’ own collective experience when providing recommendations.
- 10 September 2024
- Published by SAGE Publications in Journal of Feline Medicine and Surgery
- Vol. 26 (9)
Open AccessFeline friendly POCUS: how to implement it into your daily practice
Practical relevance: Cats are great pretenders; they often hide illness until they are critical. This makes patients of this species challenging to assess and manage in the emergency setting where quick and stress-free diagnosis and treatment are necessary. Veterinary point-of-care ultrasound (POCUS) is a rapid, evidence-based, non-invasive, repeatable, cage-side ultrasonographic examination designed to answer clinically driven questions without compromising feline wellbeing. Integrating feline friendly POCUS as an extension of the physical examination to streamline diagnostic and therapeutic interventions, thereby limiting stress and improving overall patient care, is advocated by the authors of this article. Equipment: Given the multitude of ultrasound machines and probes available that are portable, meaning they can be moved around the clinic and used patient-side, it should be possible for most practitioners to integrate POCUS into daily practice. The authors’ preferred equipment for feline POCUS is a microconvex probe and a portable machine with a fixed pre-set. This set-up allows the clinician to complete all POCUS (abdominal, lung and pleural space, and heart) without needing to move the patient, change probes or restrain the patient in a particular position, ultimately saving time, personnel and cost while maintaining patient comfort and safety. Aim: This review aims to serve as a valuable resource for veterinarians seeking to improve their feline patient care through the judicious utilisation of POCUS. In this article, the complex challenges posed by cats are addressed, and the different POCUS techniques, applications and clinical recommendations are discussed. Evidence base: This review draws on the published literature, as well as the authors’ own collective experience when providing recommendations.