Open-Circuit Fault detection and localization for a Three-Phase Gird-Connected Active Neutral Point Clamped Inverter
Authors:
- 1 April 2019
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 753-758
Abstract
This paper proposes a new fault detection method for a grid-connected three-level active neutral point clamped (ANPC) inverter. The method is able to identify the open-circuit fault and its location by calculating the current average in specified regions and considering the grid power factor. The implementation of the method does not require the additional hardware and the complex calculation.Keywords
This publication has 9 references indexed in Scilit:
- Open-circuit fault detection and localization in five-level active NPC converter2017
- A Fault-Tolerant Single-Phase Grid-Connected Inverter Topology With Enhanced Reliability for Solar PV ApplicationsIEEE Journal of Emerging and Selected Topics in Power Electronics, 2017
- Fault tolerant Active Neutral Point Clamped inverter: Short-circuit and open-circuit failures2015
- Diagnosis of open-circuit switch faults in multilevel active-NPC (ANPC) inverters2014
- Fault detection and diagnosis of grid-connected power inverters using PCA and current mean value2012
- Fault detection and reconfiguration strategy for ANPC converters2012
- Method for Detecting an Open-Switch Fault in a Grid-Connected NPC Inverter SystemIEEE Transactions on Power Electronics, 2011
- An Industry-Based Survey of Reliability in Power Electronic ConvertersIEEE Transactions on Industry Applications, 2011
- A Survey on Neutral-Point-Clamped InvertersIEEE Transactions on Industrial Electronics, 2009