A model‐based method for reporting mammographic diagnostic reference levels for any compressed breast thickness: A refined reporting approach
Open Access
- 21 August 2025
- journal article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (9) , e70206
Abstract
Background: Mammography is a critical tool for early breast cancer detection, but its use of ionizing radiation necessitates careful monitoring and optimization of patient exposure to ensure safety. Conventional methods for reporting diagnostic reference levels (DRLs) rely on wide compressed breast thickness (CBT) ranges, which lack the precision to account for individual variations, limiting their effectiveness in optimizing mammographic radiation doses. Purpose: To develop an equation‐based approach that provides a DRL for any given CBT. Methods: The 75th percentile of median average glandular dose (AGD) values from nine centers (a total of 187,704 mammograms) was employed for the DRL estimation using three approaches: (1) estimating a DRL for a CBT range assumed to represent typical women in the population (simplest/common approach), (2) reporting DRLs per different 10‐mm CBT ranges (improved approach), and (3) as a DRL equation (the proposed approach), which was generated from fitting the values of the estimated DRLs versus each corresponding CBT. The differences in these approaches’ results were compared. Results: For our population, the curve fitting of the DRLs versus their corresponding CBTs resulted in a bi‐exponential equation with high‐fitting reliability ( R 2 > 0.98). The equation approach provides continuous DRL values to serve any given CBT. The difference in the estimated DRLs by the equation approach and the improved range‐based reporting approach can range between several percentages to more than 35% and can exceed that to more than 175% when compared with the estimated simplest approach's DRL. Conclusions: The proposed DRL equation approach is reliable and can be used to provide more precise results for any given CBT value rather than the conventional range‐based reporting approaches. Vendors can adopt the proposed approach by integrating an option to input DRL equations to automate the optimization of mammographic dose.Keywords
This publication has 17 references indexed in Scilit:
- ICRP Publication 135: Diagnostic Reference Levels in Medical ImagingAnnals of the ICRP, 2017
- Radiation dose affected by mammographic composition and breast size: first application of a radiation dose management system for full-field digital mammography in Korean womenWorld Journal of Surgical Oncology, 2017
- Diagnostic reference levels for digital mammography in New South WalesJournal of Medical Imaging and Radiation Oncology, 2016
- Limitations of diagnostic reference level (DRL) and introduction of acceptable quality dose (AQD)British Journal of Radiology, 2015
- Breast Cancer Mortality in Mammographic Screening in Europe: A Review of Incidence-Based Mortality StudiesJournal of Medical Screening, 2012
- A comparison of mean glandular dose diagnostic reference levels within the all-digital Irish nationalbreast screening programme and the Irish symptomatic breast servicesRadiation Protection Dosimetry, 2012
- Optimal beam quality selection based on contrast-to-noise ratio and mean glandular dose in digital mammographyAustralasian Physics & Engineering Sciences in Medicine, 2010
- Comparison of Acquisition Parameters and Breast Dose in Digital Mammography and Screen-Film Mammography in the American College of Radiology Imaging Network Digital Mammographic Imaging Screening TrialAmerican Journal of Roentgenology, 2010
- A survey of clinical factors and patient dose in mammographyMedical Physics, 2001
- Absorbed Dose Tn Mammary RadiographyActa Radiologica: Therapy, Physics, Biology, 1976