Influence of Inverter Open Circuit Fault on Multiple Physical Quantities in the PMSM
- 6 September 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (1) , 901-916
Abstract
The fault of the drive system mainly occurs in the power transistor of the inverter. Compared with the short-circuit fault, open-circuit fault is not easy to perceive and accurately detect, and it will not cause instantaneously devastating damage to the system. In the case of the open-circuit fault, the motor will be in limp operation mode. At present, most of the research results are focused on fault detection methods, and have not analyzed the situation of multiple physical quantities in the limp mode. In this article, the system hybrid logic dynamic model in different combinations of open-circuit faults under vector control mode is established, and the transient characterization of the current is presented. Furthermore, the system-level analysis model of inverter and motor coupling for fault analysis is proposed, and the change rule of electrical parameters, magnetic field, speed, torque, and loss of PMSM under four fault modes is comprehensively studied. Based on the theory of transient temperature field and fluid dynamics, the three-dimensional global temperature analysis model with electromagnetic-temperature bidirectional coupling is established, and the thermal evolution law and limit temperature rise of permanent magnet synchronous motor (PMSM) are revealed. A lot of experiments are done to verify the analysis correctness, combining with the theoretical research results, the fault conditions, and working range of the motor that can maintain the limp operation are given.Keywords
Funding Information
- Fundamental Research Funds for the Central Universities (2019JBZ101)
This publication has 26 references indexed in Scilit:
- A Novel Diagnostic Technique for Open-Circuited Faults of Inverters Based on Output Line-to-Line Voltage ModelIEEE Transactions on Industrial Electronics, 2016
- A Real-Time Multiple Open-Circuit Fault Diagnosis Method in Voltage-Source-Inverter Fed Vector Controlled DrivesIEEE Transactions on Power Electronics, 2015
- Multiple Open-Circuit Faults Diagnosis in Back-to-Back Converters of PMSG Drives for Wind Turbine SystemsIEEE Transactions on Power Electronics, 2014
- Modeling and Control of Three-Phase PMSMs Under Open-Phase FaultIEEE Transactions on Industry Applications, 2012
- A New Algorithm for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Fed PWM Motor Drives by the Reference Current ErrorsIEEE Transactions on Industrial Electronics, 2012
- A New Approach for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Source InvertersIEEE Transactions on Industry Applications, 2011
- Electrothermal Analysis of Induction Motor With Compound Cage Rotor Used for PHEVIEEE Transactions on Industrial Electronics, 2009
- Open-Transistor Fault Diagnostics in Voltage-Source Inverters by Analyzing the Load CurrentsIEEE Transactions on Industrial Electronics, 2009
- FPGA-Based Real-Time Power Converter Failure Diagnosis for Wind Energy Conversion SystemsIEEE Transactions on Industrial Electronics, 2008
- Convection Heat Transfer and Flow Calculations Suitable for Electric Machines Thermal ModelsIEEE Transactions on Industrial Electronics, 2008