Randomized clinical trial of the i-gel™ and Magill tracheal tube or single-use ILMA™ and ILMA™ tracheal tube for blind intubation in anaesthetized patients with a predicted difficult airway
Open Access
- 7 June 2011
- journal article
- research article
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 107 (2) , 243-250
Abstract
The single-use supraglottic airway device i-gel™ has been described in several case reports as a conduit for intubation, but no prospective data about success rates of blind intubation are available. Therefore, we performed this prospective randomized controlled trial to compare the success rate of blind tracheal intubation with a Magill PVC tube through the i-gel™ with intubation using an sILMA™ PVC tube through the single-use intubating laryngeal mask airway (sILMA™). With ethics committee approval and written informed consent, 80 patients with predictors of a difficult airway were computer randomized to either supraglottic airway device (SAD). The corresponding tracheal tube (TT) was introduced through the SAD under fibreoptic visualization but without fibreoptic guidance. Primary outcome was blind intubation success rate. Times, airway leak pressure, fibreoptic view, and adverse events were recorded. To control for the influence of the TT, we compared data from 40 patients described in an accompanying study (sILMA™ with Magill TT and i-gel™ with sILMA™ TT). Blind intubation success rate through the sILMA™ (69%) was higher than with the i-gel™ (15%, P<0.001). Data from the other patient group excluded the TT type as the primary cause for the difference in success rate. Removal of SADs was without problems with no difference between the type of SAD. Blind tracheal intubation using the sILMA™ tube through the sILMA™ is much more successful than blind intubation with a Magill PVC tube through the i-gel™. Because of its low success rate, we would not recommend blind intubation through the i-gel™.Keywords
This publication has 25 references indexed in Scilit:
- A comparison of the i‐gel™ with the LMA‐Unique™ in non‐paralysed anaesthetised adult patientsAnaesthesia, 2009
- A randomised crossover trial comparing the i‐gel supraglottic airway and classic laryngeal mask airway*Anaesthesia, 2009
- Evaluation of the i-gel airway in 300 patientsEuropean Journal of Anaesthesiology, 2008
- A Comparison of a Silicone Wire-Reinforced Tube with the Parker and Polyvinyl Chloride Tubes for Tracheal Intubation Through an Intubating Laryngeal Mask Airway in Patients with Normal Airways Undergoing General AnesthesiaAnesthesia & Analgesia, 2008
- Comparison of the single use and reusable intubating laryngeal mask airwayAnaesthesia, 2007
- Difficult Airway Society guidelines for management of the unanticipated difficult intubationAnaesthesia, 2004
- Performance of the Size 5 Laryngeal Mask Airway in Males and FemalesAINS - Anästhesiologie · Intensivmedizin · Notfallmedizin · Schmerztherapie, 2000
- Use of the Intubating Laryngeal Mask AirwayAnesthesiology, 2000
- Difficult tracheal intubation: a retrospective studyAnaesthesia, 1987
- A clinical sign to predict difficult tracheal intubation; a prospective studyCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1985