LTLorenz Theiler

Lorenz Theiler

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lorenz Theiler has a total of 24 co-authors. Here are the top co-authors by number of shared publications:

  • M. Kleine-Brueggeney

    Department of Anaesthesiology and Pain Therapy, Bern University Hospital, University of Bern, Bern, Switzerland

    6 shared publications
  • R. Greif

    Department of Anaesthesiology and Pain Therapy, Bern University Hospital, University of Bern, Bern, Switzerland

    4 shared publications
  • Robert Greif

    Faculty of Medicine, University of Bern, Bern, Schweiz

    4 shared publications
  • S. Nabecker

    University Hospital Inselspital and University of Bern, Dept of Anaesthesiology & Pain Medicine, Bern, Switzerland

    3 shared publications
  • C. Riggenbach

    University Hospital Inselspital and University of Bern, Dept of Anaesthesiology & Pain Medicine, Bern, Switzerland

    2 shared publications
  • M. Kotarlic

    University Hospital Inselspital and University of Bern, Dept of Anaesthesiology & Pain Medicine, Bern, Switzerland

    2 shared publications

Latest Publications

  • Loss of Resistance: A Randomized Controlled Trial Assessing 4 Low-fidelity Epidural Puncture Simulators

    by T.H. Pedersen, J. Meuli, E.J. Plazikowski, M. Buttenberg, M. Kleine-Brueggeney, C. Seidl, L. Theiler, R. Greif

    (Eur J Anaesthesiol 2017;34:602–608) Placing an epidural catheter for administration of regional anesthesia is considered to be a difficult skill for anesthesia residents to master. In one study, first-year residents had only an 80% success rate after 90 attempts at epidural catheter placement. With such a steep learning curve, it would be beneficial to have significant simulated experiences before performing the procedure on patients. Several simulators are commercially available for practicing identification of the epidural space using a loss of resistance (LOR) technique. However, these simulators can be quite expensive, ranging in price between €1500 and 3000. The use of various fruits have been studied to simulate the feel of LOR during epidural procedures with the banana found to best simulate the sensation. In this single-blinded, randomized, controlled study the investigators compared 3 commercially available simulators and a banana for their ability to simulate the LOR feel essential to successful epidural placement.


  • Clinical performance of five pediatric supraglottic airway devices

    by S. Nabecker, L. Theiler, C. Riggenbach, M. Kleine-Brueggeney, R. Greif

    • 1 October 2012
      • Vol. 78  (10) , 1088-94

    Survey on controversies in airway management among anesthesiologists in the UK, Austria and Switzerland.

    by L Theiler, H Fischer, N Voelke, R Basciani, F Hasty, Robert Greif

    While surveys about anesthesia practice appear regularly in the anesthesia literature, they are usually bound to one country. We compared the approach to specific airway management issues among anesthesiologists from three different European countries. A questionnaire was distributed during the main session of three anesthesia meetings in Austria (A), the UK, and Switzerland (CH). Questions concerned whether anesthesiologists routinely check for risk factors associated with difficult mask ventilation; whether anesthesiologists are used to mask ventilate prior to administering neuromuscular blocking drugs (NMBD); whether anesthesiologists apply cricoid pressure. We evaluated 266 questionnaires. No significant differences in the frequency of checking predictors were found, except for "age" (UK: 28%, A: 13%, CH:11%, P=0.01). Fewer anesthesiologists from the UK always check mask ventilation before NMBD (UK: 34%, A: 72%, CH: 67%, P<0.001); but they check mask ventilation more often when risk factors are present (UK: 36%, A: 13%, CH: 20%, P=0.004). Very few anesthesiologists from the UK never apply cricoid pressure (UK: 2%, A: 40%, CH: 49%, P<0.001), but almost all of them apply it in case of rapid sequence intubation (UK: 96%, A: 52%, CH:30%, P<0.001). Answers from anesthesiologists in the UK differed significantly from those in A and CH. Anesthesiologists in the UK check mask ventilation after induction less frequently, but they check more often when risk factors of difficult mask ventilation are present. Cricoid pressure seems to remain an important part of the rapid sequence induction technique in the UK, whereas anesthesiologists in Austria and Switzerland rely less on this technique.

    • 6 February 2012
      • Vol. 78  (5) , 550-5

    Standard vs. point-of-care measurement of fibrinogen: potential impact on clinical decisions.

    by N Urwyler, L Theiler, M Hirschberg, M Kleine-Brueggeney, G Colucci, R Greif

    Intraoperative major bleeding is a common complication during surgery and can lead to the transfusion of blood products and/or procoagulant drugs. This is a therapeutic challenge, and adherence to guidelines is desirable to preserve blood product resources. The intraoperative administration of fibrinogen concentrate, a pro-coagulant drug, in bleeding patients might reduce the use and therefore the risks associated with blood products. In this observational pilot study we determined whether fibrinogen measured by point-of-care thromboelastometry (Rotem®, fibtem-test) would lead to a similar therapeutical decision concerning the administration of fibrinogen concentrate when compared to the standard method (Clauss). Blood samples of 36 patients undergoing major surgery were simultaneously analyzed using both methods. According to the cutoff values of current guidelines based on the standard method, no patient would receive fibrinogen concentrate. In comparison, if point-of-care thromboelastometry were used and its cutoff for fibrinogen applied, 16 patients (44%, P<0.001) would receive fibrinogen concentrate. The method used for intraoperative coagulation monitoring has a major impact on therapeutic decisions concerning the use of blood products and/or pro-coagulant drugs. If fibrinogen was measured by point-of-care thromboelastometry instead of the standard method according to Clauss, the use of fibrinogen concentrate would increase significantly and less fresh frozen plasma would be administered.


  • Open Access

    Randomized trial comparing the i-gel™ and Magill tracheal tube with the single-use ILMA™ and ILMA™ tracheal tube for fibreoptic-guided intubation in anaesthetized patients with a predicted difficult airway

    by M. Kleine-Brueggeney, L. Theiler, N. Urwyler, A. Vogt, R. Greif

    The i-gel™ is a single-use supraglottic airway device (SAD) that allows fibreoptic-guided tracheal intubation through the device. Until now, no prospective data for this procedure are available. Therefore, in a prospective randomized controlled trial, we evaluated fibreoptic-guided tracheal intubation with a standard Rüsch™ PVC tracheal tube (TT) through the i-gel™ compared with the single-use ILMA™ (sILMA™) TT through the sILMA™ in patients with a predicted difficult airway. With ethics committee approval and written informed consent, 160 patients were randomly assigned to either SAD. After placement of the SAD, a fibreoptic bronchoscope was introduced into the trachea as a railroad for the TT. Primary outcome variable was the first-attempt fibreoptic-guided intubation success rate. Secondary variables included time for insertion and intubation, airway leak pressures, fibreoptic view, and adverse events. Data are presented as mean (sd) or percentages. A P-value of P=0.21). Most of the failed intubations were rescued by conventional laryngoscopy. Airway leak pressure was higher for the sILMA™. There were no problems during removal of either type of SAD. Fibreopic-guided tracheal intubation through the i-gel™ using a standard Rüsch™ Magill TT is successful and an alternative to the sILMA™ with the sILMA™ TT.


  • Open Access

    Randomized clinical trial of the i-gel™ and Magill tracheal tube or single-use ILMA™ and ILMA™ tracheal tube for blind intubation in anaesthetized patients with a predicted difficult airway

    by L. Theiler, M. Kleine-Brueggeney, N. Urwyler, T. Graf, C. Luyet, R. Greif

    The single-use supraglottic airway device i-gel™ has been described in several case reports as a conduit for intubation, but no prospective data about success rates of blind intubation are available. Therefore, we performed this prospective randomized controlled trial to compare the success rate of blind tracheal intubation with a Magill PVC tube through the i-gel™ with intubation using an sILMA™ PVC tube through the single-use intubating laryngeal mask airway (sILMA™). With ethics committee approval and written informed consent, 80 patients with predictors of a difficult airway were computer randomized to either supraglottic airway device (SAD). The corresponding tracheal tube (TT) was introduced through the SAD under fibreoptic visualization but without fibreoptic guidance. Primary outcome was blind intubation success rate. Times, airway leak pressure, fibreoptic view, and adverse events were recorded. To control for the influence of the TT, we compared data from 40 patients described in an accompanying study (sILMA™ with Magill TT and i-gel™ with sILMA™ TT). Blind intubation success rate through the sILMA™ (69%) was higher than with the i-gel™ (15%, P<0.001). Data from the other patient group excluded the TT type as the primary cause for the difference in success rate. Removal of SADs was without problems with no difference between the type of SAD. Blind tracheal intubation using the sILMA™ tube through the sILMA™ is much more successful than blind intubation with a Magill PVC tube through the i-gel™. Because of its low success rate, we would not recommend blind intubation through the i-gel™.