Abstract
Lead-lined galvanized iron pipe (LLGIP), installed across the USA during the early 1900s, often goes underreported because of visual exterior similarities and physical material characteristics to galvanized iron pipes (GIPs). However, their interior lead lining interacts with drinking water like traditional lead service lines and will be treated as such in accordance with the USEPA’s Lead and Copper Rule Improvements. Handheld X-ray fluorescence (hhXRF), widely used for elemental analyses of various matrices, is a potential service line identification tool, but it has not yet been comprehensively tested in a controlled setting for this application. This study evaluated the applicability of 57Co K-shell hhXRF as a method for identifying service line materials. A total of 88 exhumed field pipes were gathered and analyzed. Lead results revealed a significantly lower average lead count of 282 (σ 222) cps for GIPs compared to an average of 8,696 (σ 5,861) cps for LLGIPs. The study results demonstrated under laboratory conditions the hhXRF’s ability to 100% successfully differentiate between GIPs and LLGIPs through exterior analysis, a distinction previously only available by physical extraction of the pipe or water sampling. hhXRF did not consistently distinguish LLGIP from brass; thus, existing physical methods are still needed for these materials.