Michael K. DeSantis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Michael K. DeSantis has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Jennifer Tully
US Environmental Protection Agency
5 shared publications - Michael R. Schock
United States Environmental Protection Agency, Office of Research & Development Cincinnati Ohio USA
5 shared publications - Darren A. Lytle
Office of Research and Development (ORD), U.S. Environmental Protection Agency, 26 W. Martin Luther King Dr., Cincinnati, Ohio 45268, United States
4 shared publications - Simoni Triantafyllidou
U.S. Environmental Protection Agency, Office of Research and Development, Center for Environmental Solutions & Emergency Response, Water Infrastructure Division, Drinking Water Management Branch, Cincinnati, OH, USA
2 shared publications Casey Formal
Office of Research and Development, Center for Environmental Solutions & Emergency Response, Water Infrastructure Division, Oak Ridge Associated Universities (ORAU) Student Services Contractor to the U.S. Environmental Protect Agency, Cincinnati 45268, United States
1 shared publicationChantaly Villalona
US Environmental Protection Agency
1 shared publication
Latest Publications
- 9 July 2026
- Published by American Chemical Society (ACS) in Environmental Science & Technology Letters
- Vol. 13 (8) , 1071-1076
Service Line Characterization via Handheld Lead K-Shell X-ray Fluorescence
Lead-lined galvanized iron pipe (LLGIP), installed across the USA during the early 1900s, often goes underreported because of visual exterior similarities and physical material characteristics to galvanized iron pipes (GIPs). However, their interior lead lining interacts with drinking water like traditional lead service lines and will be treated as such in accordance with the USEPA’s Lead and Copper Rule Improvements. Handheld X-ray fluorescence (hhXRF), widely used for elemental analyses of various matrices, is a potential service line identification tool, but it has not yet been comprehensively tested in a controlled setting for this application. This study evaluated the applicability of 57Co K-shell hhXRF as a method for identifying service line materials. A total of 88 exhumed field pipes were gathered and analyzed. Lead results revealed a significantly lower average lead count of 282 (σ 222) cps for GIPs compared to an average of 8,696 (σ 5,861) cps for LLGIPs. The study results demonstrated under laboratory conditions the hhXRF’s ability to 100% successfully differentiate between GIPs and LLGIPs through exterior analysis, a distinction previously only available by physical extraction of the pipe or water sampling. hhXRF did not consistently distinguish LLGIP from brass; thus, existing physical methods are still needed for these materials.
- 9 July 2026
- Published by American Chemical Society (ACS) in Environmental Science & Technology Letters
- Vol. 13 (8) , 1071-1076
Service Line Characterization via Handheld Lead K-Shell X-ray Fluorescence
Lead-lined galvanized iron pipe (LLGIP), installed across the USA during the early 1900s, often goes underreported because of visual exterior similarities and physical material characteristics to galvanized iron pipes (GIPs). However, their interior lead lining interacts with drinking water like traditional lead service lines and will be treated as such in accordance with the USEPA’s Lead and Copper Rule Improvements. Handheld X-ray fluorescence (hhXRF), widely used for elemental analyses of various matrices, is a potential service line identification tool, but it has not yet been comprehensively tested in a controlled setting for this application. This study evaluated the applicability of 57Co K-shell hhXRF as a method for identifying service line materials. A total of 88 exhumed field pipes were gathered and analyzed. Lead results revealed a significantly lower average lead count of 282 (σ 222) cps for GIPs compared to an average of 8,696 (σ 5,861) cps for LLGIPs. The study results demonstrated under laboratory conditions the hhXRF’s ability to 100% successfully differentiate between GIPs and LLGIPs through exterior analysis, a distinction previously only available by physical extraction of the pipe or water sampling. hhXRF did not consistently distinguish LLGIP from brass; thus, existing physical methods are still needed for these materials.
- Open Access
- 17 March 2022
- Published by Wiley in AWWA Water Science
- Vol. 4 (2)
A holistic approach to lead pipe scale analysis: Importance, methodology, and limitations
With lead service lines (LSLs) remaining for decades to come, scale analyses are critical to helping limit lead exposure from drinking water. This laboratory has used an integrated suite of analytical techniques to characterize the elemental composition, mineral identification, and physical features of scales, helping the water industry to evaluate, predict, and reduce lead corrosion. The methods used in this laboratory to prepare and analyze the LSL scale, and guidance to achieving reliable and meaningful results, are described. Primary methods include the following: optical microscopy, powder X‐ray diffraction, inductively coupled plasma spectroscopy, X‐ray fluorescence, scanning electron microscopy with energy dispersive spectroscopy, combustion and coulometric analyses of C and S, and X‐ray absorption spectroscopy. Examples of associated pitfalls and ways to avoid them are provided, including pipe excavation/transport, sample preparation, analysis, and data interpretation. Illustrative examples are presented of practical scale analysis questions that could be answered by combinations of pipe scale analyses.
- 17 March 2022
- Published by Wiley in AWWA Water Science
- Vol. 4 (2)
Open AccessA holistic approach to lead pipe scale analysis: Importance, methodology, and limitations
With lead service lines (LSLs) remaining for decades to come, scale analyses are critical to helping limit lead exposure from drinking water. This laboratory has used an integrated suite of analytical techniques to characterize the elemental composition, mineral identification, and physical features of scales, helping the water industry to evaluate, predict, and reduce lead corrosion. The methods used in this laboratory to prepare and analyze the LSL scale, and guidance to achieving reliable and meaningful results, are described. Primary methods include the following: optical microscopy, powder X‐ray diffraction, inductively coupled plasma spectroscopy, X‐ray fluorescence, scanning electron microscopy with energy dispersive spectroscopy, combustion and coulometric analyses of C and S, and X‐ray absorption spectroscopy. Examples of associated pitfalls and ways to avoid them are provided, including pipe excavation/transport, sample preparation, analysis, and data interpretation. Illustrative examples are presented of practical scale analysis questions that could be answered by combinations of pipe scale analyses.
- Open Access
- 16 December 2020
- Published by Elsevier in Environment International
- Vol. 146, 106259
Variability and sampling of lead (Pb) in drinking water: Assessing potential human exposure depends on the sampling protocol
- 16 December 2020
- Published by Elsevier in Environment International
- Vol. 146, 106259
Open AccessVariability and sampling of lead (Pb) in drinking water: Assessing potential human exposure depends on the sampling protocol
- 26 October 2020
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 54 (22) , 14302-14311
Orthophosphate Interactions with Destabilized PbO2 Scales
This research presents two case studies in which a change in the disinfectant from free chlorine to chloramine caused an increase in lead corrosion. In both systems, the predominantly tetravalent lead (PbO2) scales destabilized as a result of disinfectant change. Orthophosphate corrosion control was used in both systems, and the effect of this treatment chemical on the destabilized PbO2 scales was examined. The absence of chemical reactivity between PbO2 and phosphorus is well known, and this research confirms that phosphorus does not interact with the legacy PbO2 scales. Instead, phosphorus and calcium were found to permeate through the destabilized PbO2 material and react with divalent lead [Pb(II)] at the surface of a basal litharge (PbO) layer. This reaction precipitated a crystalline lead phosphate in both systems, which could not be specifically identified by any known powder diffraction files. Further analysis suggested that the compound formed was not the typically modeled hydroxypyromorphite but rather a calcium-substituted hydroxypyromorphite. During scale formation, calcium is frequently bound to the Pb(II) phosphate crystal lattice structure, causing measurable crystal lattice distortion in powder X-ray diffraction patterns. The results of this study illustrate the longevity of legacy scales and how disequilibrium compounds persist long after treatment changes have been made.
- 26 October 2020
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 54 (22) , 14302-14311
Orthophosphate Interactions with Destabilized PbO2 Scales
This research presents two case studies in which a change in the disinfectant from free chlorine to chloramine caused an increase in lead corrosion. In both systems, the predominantly tetravalent lead (PbO2) scales destabilized as a result of disinfectant change. Orthophosphate corrosion control was used in both systems, and the effect of this treatment chemical on the destabilized PbO2 scales was examined. The absence of chemical reactivity between PbO2 and phosphorus is well known, and this research confirms that phosphorus does not interact with the legacy PbO2 scales. Instead, phosphorus and calcium were found to permeate through the destabilized PbO2 material and react with divalent lead [Pb(II)] at the surface of a basal litharge (PbO) layer. This reaction precipitated a crystalline lead phosphate in both systems, which could not be specifically identified by any known powder diffraction files. Further analysis suggested that the compound formed was not the typically modeled hydroxypyromorphite but rather a calcium-substituted hydroxypyromorphite. During scale formation, calcium is frequently bound to the Pb(II) phosphate crystal lattice structure, causing measurable crystal lattice distortion in powder X-ray diffraction patterns. The results of this study illustrate the longevity of legacy scales and how disequilibrium compounds persist long after treatment changes have been made.
- 22 October 2020
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 54 (21) , 13672-13679
Lead Particle Size Fractionation and Identification in Newark, New Jersey’s Drinking Water
Following a pH reduction in their drinking water over a span of more than 20 years, the City of Newark, New Jersey, has struggled with elevated lead (Pb) release from Pb service lines and domestic plumbing in the zone fed by the Pequannock Water Treatment Plant. In response, Newark initiated orthophosphate addition and provided faucet-mounted point-of-use (POU) filters and pitcher filters certified for Pb and particulate reduction under NSF/ANSI Standards 53 and 42 to residential homes in that zone. Water chemistry analysis and size fractionation sampling were performed at four of these houses. Analysis of the particulate material retained by the fractionation filters revealed that Pb was dominantly present in the water as fine Pb(II) orthophosphate particles. A considerable amount of the particulates occurred as a nanoscale fraction that sometimes passed through the POU faucet or pitcher filtration units. Scanning electron microscopy, transmission electron microscopy, and energy-dispersive spectroscopy analyses showed that the nanoparticles (5(PO4)3Cl. Electron diffraction and X-ray analyses supported the presence of hydroxypyromorphite and chloropyromorphite nanoparticles and the size range estimates from the imaging. This research confirmed that nonadherent Pb(II)-orthophosphate nanoparticles were an important form of Pb in drinking water in the Pequannock water quality zone of Newark.
- 22 October 2020
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 54 (21) , 13672-13679
Lead Particle Size Fractionation and Identification in Newark, New Jersey’s Drinking Water
Following a pH reduction in their drinking water over a span of more than 20 years, the City of Newark, New Jersey, has struggled with elevated lead (Pb) release from Pb service lines and domestic plumbing in the zone fed by the Pequannock Water Treatment Plant. In response, Newark initiated orthophosphate addition and provided faucet-mounted point-of-use (POU) filters and pitcher filters certified for Pb and particulate reduction under NSF/ANSI Standards 53 and 42 to residential homes in that zone. Water chemistry analysis and size fractionation sampling were performed at four of these houses. Analysis of the particulate material retained by the fractionation filters revealed that Pb was dominantly present in the water as fine Pb(II) orthophosphate particles. A considerable amount of the particulates occurred as a nanoscale fraction that sometimes passed through the POU faucet or pitcher filtration units. Scanning electron microscopy, transmission electron microscopy, and energy-dispersive spectroscopy analyses showed that the nanoparticles (5(PO4)3Cl. Electron diffraction and X-ray analyses supported the presence of hydroxypyromorphite and chloropyromorphite nanoparticles and the size range estimates from the imaging. This research confirmed that nonadherent Pb(II)-orthophosphate nanoparticles were an important form of Pb in drinking water in the Pequannock water quality zone of Newark.
- Open Access
- 4 March 2019
- Published by Wiley in AWWA Water Science
- Vol. 1 (2)
Water quality–pipe deposit relationships in Midwestern lead pipes
The conventional wisdom of lead‐scale solubility has been built over the years by geochemical solubility models, experimental studies, and field sampling using multiple protocols. Rarely have the mineral phases from scales formed in real‐world drinking water lead service lines (LSLs) been compared with theoretical predictions. In this study, model predictions are compared with LSL scales from 22 drinking water distribution systems. The results show that only 9 of the 22 systems had LSL scales that followed model predictions. The remaining systems had unpredictable scales, some with unknown lead release characteristics, demonstrating that predicting scale formation and lead release solely by models cannot be relied on in all cases to protect human health. Therefore, for many systems with LSLs, pilot studies with existing LSL scales will be necessary to evaluate and optimize corrosion control, and correspondingly, appropriate residential water sampling will be needed to demonstrate consistent and optimal system corrosion control.
- 4 March 2019
- Published by Wiley in AWWA Water Science
- Vol. 1 (2)
Open AccessWater quality–pipe deposit relationships in Midwestern lead pipes
The conventional wisdom of lead‐scale solubility has been built over the years by geochemical solubility models, experimental studies, and field sampling using multiple protocols. Rarely have the mineral phases from scales formed in real‐world drinking water lead service lines (LSLs) been compared with theoretical predictions. In this study, model predictions are compared with LSL scales from 22 drinking water distribution systems. The results show that only 9 of the 22 systems had LSL scales that followed model predictions. The remaining systems had unpredictable scales, some with unknown lead release characteristics, demonstrating that predicting scale formation and lead release solely by models cannot be relied on in all cases to protect human health. Therefore, for many systems with LSLs, pilot studies with existing LSL scales will be necessary to evaluate and optimize corrosion control, and correspondingly, appropriate residential water sampling will be needed to demonstrate consistent and optimal system corrosion control.
- 15 February 2018
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 52 (6) , 3365-3374
Mineralogical Evidence of Galvanic Corrosion in Drinking Water Lead Pipe Joints
Galvanic corrosion as a mechanism of toxic lead release into drinking water has been under scientific debate in the U.S. for over 30 years. Visual and mineralogical analysis of 28 lead pipe joints, excavated after 60+ years from 8 U.S. water utilities, provided the first direct view of three distinct galvanic corrosion patterns in practice: (1) no evidence of galvanic corrosion; (2) galvanic corrosion with lead cathode; (3) galvanic corrosion with lead anode. Pattern 3 is consistent with empirical galvanic series (lead→brass→copper in order of increasing nobility) and poses the greatest risk of Pb exposure. Pattern 2 is consistent with galvanic battery reversion. The identification of copper-sulfate minerals (Pattern 2), and lead-sulfate and lead-chloride minerals (Pattern 3) in galvanic zones illustrated the migration of chloride and sulfate toward the anode. Geochemical modeling confirmed the required pH drop from the bulk water level to at least pH 3.0-4.0 (Pattern 2) and pH2 formation.
- 15 February 2018
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 52 (6) , 3365-3374
Mineralogical Evidence of Galvanic Corrosion in Drinking Water Lead Pipe Joints
Galvanic corrosion as a mechanism of toxic lead release into drinking water has been under scientific debate in the U.S. for over 30 years. Visual and mineralogical analysis of 28 lead pipe joints, excavated after 60+ years from 8 U.S. water utilities, provided the first direct view of three distinct galvanic corrosion patterns in practice: (1) no evidence of galvanic corrosion; (2) galvanic corrosion with lead cathode; (3) galvanic corrosion with lead anode. Pattern 3 is consistent with empirical galvanic series (lead→brass→copper in order of increasing nobility) and poses the greatest risk of Pb exposure. Pattern 2 is consistent with galvanic battery reversion. The identification of copper-sulfate minerals (Pattern 2), and lead-sulfate and lead-chloride minerals (Pattern 3) in galvanic zones illustrated the migration of chloride and sulfate toward the anode. Geochemical modeling confirmed the required pH drop from the bulk water level to at least pH 3.0-4.0 (Pattern 2) and pH2 formation.