Predictive value of pediatric respiratory-induced diaphragm motion quantified using pre-treatment 4DCT and CBCTs
Open Access
- 11 October 2018
- journal article
- research article
- Published by Springer Nature in Radiation Oncology
- Vol. 13 (1) , 198
Abstract
In adults, a single pre-treatment four-dimensional CT (4D-CT) acquisition is often used to account for respiratory-induced target motion during radiotherapy. However, studies have indicated that a 4D-CT is not always representative for respiratory motion. Our aim was to investigate whether respiratory-induced diaphragm motion in children on a single pre-treatment 4DCT can accurately predict respiratory-induced diaphragm motion as observed on cone beam CTs (CBCTs). Twelve patients (mean age 14.5 yrs.; range 8.6–17.9 yrs) were retrospectively included based on visibility of the diaphragm on abdominal or thoracic imaging data acquired during free breathing. A 4DCT for planning purposes and daily/weekly CBCTs (total 125; range 4–29 per patient) acquired prior to dose delivery were available. The amplitude, corresponding to the difference in position of the diaphragm in cranial-caudal direction in end-inspiration and end-expiration phases, was extracted from the 4DCT (A4DCT). The amplitude in CBCTs (ACBCT) was defined as displacement between averaged in- and expiration diaphragm positions on corresponding projection images, and the distribution of ACBCT was compared to A4DCT (one-sample t-test, significance level p < 0.05). Over all patients, the mean A4DCT was 10.4 mm and the mean ACBCT 11.6 mm. For 9/12 patients, A4DCT differed significantly (p < 0.05) from ACBCT. Differences > 3 mm were found in 69/125 CBCTs (55%), with A4DCT mostly underestimating ACBCT. For 7/12 patients, diaphragm positions differed significantly from the baseline position. Respiratory-induced diaphragm motion determined on 4DCT does not accurately predict the daily respiratory-induced diaphragm motion observed on CBCTs, as the amplitude and baseline position differed statistically significantly in the majority of patients. Regular monitoring of respiratory motion during the treatment course using CBCTs could yield a higher accuracy when a daily adaptation to the actual breathing amplitude takes place.Keywords
Funding Information
- KWF Kankerbestrijding (2016-10113)
This publication has 34 references indexed in Scilit:
- An analysis of respiratory induced kidney motion on four-dimensional computed tomography and its implications for stereotactic kidney radiotherapyRadiation Oncology, 2013
- Planning 4-Dimensional Computed Tomography (4DCT) Cannot Adequately Represent Daily Intrafractional Motion of Abdominal TumorsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2013
- Novel Assessment of Renal Motion in Children as Measured via Four-Dimensional Computed TomographyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Quantification of the Variability of Diaphragm Motion and Implications for Treatment Margin ConstructionInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Analysis of abdominal organ motion using four-dimensional CTChinese Journal of Cancer, 2009
- Radiation Therapy Preparation by a Multidisciplinary Team for Childhood Cancer Patients Aged 3½ to 6 YearsJournal of Pediatric Oncology Nursing, 2009
- Comparison of Different Strategies to Use Four-Dimensional Computed Tomography in Treatment Planning for Lung Cancer PatientsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- Measurement of inter and intra fraction organ motion in radiotherapy using cone beam CT projection imagesPhysics in Medicine & Biology, 2008
- Active Breathing Control for Hodgkin’s Disease in Childhood and Adolescence: Feasibility, Advantages, and LimitsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Phase versus amplitude sorting of 4D‐CT dataJournal of Applied Clinical Medical Physics, 2006