JVJorrit Visser

Jorrit Visser

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jorrit Visser has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Dosimetric comparison of library of plans and online MRI-guided radiotherapy of cervical cancer in the presence of intrafraction anatomical changes

    by J. Visser, P. de Boer, K. F. Crama, Z. van Kesteren, C. R. N. Rasch, L. J. A. Stalpers, A. Bel

    Online magnetic resonance imaging (MRI)-guided radiotherapy of cervical cancer has the potential to further reduce dose to organs at risk (OAR) as compared to a library of plans (LOP) approach. This study presents a dosimetric comparison of an MRI-guided strategy with a LOP strategy taking intrafraction anatomical changes into account. The 14 patients included in this study were treated with chemo radiation at our institute and received weekly MRIs after informed consent. The MRI-guided strategy consisted of treatment plans created on the weekly sagittal MRI with 3 mm and 5 mm planning target volume (PTV) margin for clinical target volume (CTV) cervix-uterus (MRI_3mm and MRI_5mm). The plans for the LOP strategy were based on interpolations of CTV cervix-uterus on pretreatment full and empty bladder scans. Dose volume histogram (DVH) parameters were compared for targets and OARs as delineated on the weekly transversal MRI, which was acquired on average 10 min after the sagittal MRI. For the MRI_5mm strategy D98% of the high-risk CTV was at least 95% for all weekly MRIs of all patients, while for the LOP and MRI_3mm strategy this requirement was not satisfied for at least one weekly MRI for 1 and 3 patients, respectively. The average reduction of the volume of the reference dose (95% of the prescribed dose) as compared to the LOP strategy was 464 cm3 for the MRI_3mm strategy, and 422 cm3 for the MRI_5mm strategy. The bowel bag constraint V40Gy < 350 cm3 was violated for 13 patients for the LOP strategy and for 5 patients for both MRI_3mm and MRI_5mm strategy. With online MRI-guided radiotherapy of cervical cancer considerable sparing of OARs can be achieved. If a new treatment plan can be generated and delivered within 10 min, an online MRI-guided strategy with a 5 mm PTV margin for CTV cervix-uterus is sufficient to account for intrafraction anatomical changes. NL44492.018.13.


  • Open Access

    Predictive value of pediatric respiratory-induced diaphragm motion quantified using pre-treatment 4DCT and CBCTs

    by Sophie C. Huijskens, Irma W. E. M. van Dijk, Jorrit Visser, Brian V. Balgobind, Coen R. N. Rasch, Tanja Alderliesten, Arjan Bel

    In adults, a single pre-treatment four-dimensional CT (4D-CT) acquisition is often used to account for respiratory-induced target motion during radiotherapy. However, studies have indicated that a 4D-CT is not always representative for respiratory motion. Our aim was to investigate whether respiratory-induced diaphragm motion in children on a single pre-treatment 4DCT can accurately predict respiratory-induced diaphragm motion as observed on cone beam CTs (CBCTs). Twelve patients (mean age 14.5 yrs.; range 8.6–17.9 yrs) were retrospectively included based on visibility of the diaphragm on abdominal or thoracic imaging data acquired during free breathing. A 4DCT for planning purposes and daily/weekly CBCTs (total 125; range 4–29 per patient) acquired prior to dose delivery were available. The amplitude, corresponding to the difference in position of the diaphragm in cranial-caudal direction in end-inspiration and end-expiration phases, was extracted from the 4DCT (A4DCT). The amplitude in CBCTs (ACBCT) was defined as displacement between averaged in- and expiration diaphragm positions on corresponding projection images, and the distribution of ACBCT was compared to A4DCT (one-sample t-test, significance level p < 0.05). Over all patients, the mean A4DCT was 10.4 mm and the mean ACBCT 11.6 mm. For 9/12 patients, A4DCT differed significantly (p < 0.05) from ACBCT. Differences > 3 mm were found in 69/125 CBCTs (55%), with A4DCT mostly underestimating ACBCT. For 7/12 patients, diaphragm positions differed significantly from the baseline position. Respiratory-induced diaphragm motion determined on 4DCT does not accurately predict the daily respiratory-induced diaphragm motion observed on CBCTs, as the amplitude and baseline position differed statistically significantly in the majority of patients. Regular monitoring of respiratory motion during the treatment course using CBCTs could yield a higher accuracy when a daily adaptation to the actual breathing amplitude takes place.


  • Open Access

    Quality assurance of the PREOPANC trial (2012-003181-40) for preoperative radiochemotherapy in pancreatic cancer

    by Eva Versteijne, Eelco Lens, Astrid van der Horst, Arjan Bel, Jorrit Visser, Cornelis J. A. Punt, Mustafa Suker, Casper H. J. van Eijck, Geertjan van Tienhoven

    The Dutch Pancreatic Cancer Group initiated the national, multicentre, controlled PREOPANC trial, randomising between preoperative radiochemotherapy and direct explorative laparotomy for patients with (borderline) resectable pancreatic cancer. The aim of this dummy run is to evaluate compliance with the radiotherapy protocol of this trial, and the quality of delineation and radiation plans.