Active Humidity Control Chamber for Desorption Electrospray Ionization-Mass Spectrometry Imaging Applications
Open Access
- 22 August 2025
- journal article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 36 (9) , 1995-1999
Abstract
Ambient ionization techniques enable mass spectrometry (MS) to expand into broader experimental contexts, although it is increasingly clear that results are influenced by the environmental conditions at the site of sampling. Desorption electrospray ionization (DESI), in particular, is affected by variations in relative humidity (RH) levels. Here we describe the design, development, and construction of an environmental control chassis that can actively modulate RH within ± 3% of user-defined set points across a broad humidity range (15%-70% RH). Preliminary characterization demonstrated differential analyte responses across a range of set points, with observed enhancement of leucine-enkephalin, sulfadimethoxine (negative mode), and maltose (positive mode) in response to increased humidity. The measurable differences in analyte signals across discrete humidity set points underscore the importance of environmental control in ambient ionization strategies. The humidity control system outlined here can be translated to other DESI platforms, with construction information provided herein.Keywords
Funding Information
- Biological and Environmental Research (DE-SC0019404, DE-SC0022207)
This publication has 15 references indexed in Scilit:
- Desorption Electrospray Ionization Cyclic Ion Mobility-Mass Spectrometry Imaging for Traumatic Brain Injury Spatial MetabolomicsAnalytical Chemistry, 2024
- Effects of Relative Humidity and Phase on the Molecular Detection of Nascent Sea Spray Aerosol Using Extractive Electrospray IonizationAnalytical Chemistry, 2024
- Desorption Electrospray Ionization Mass Spectrometry: 20 YearsAccounts of Chemical Research, 2023
- Spatiochemically Profiling Microbial Interactions with Membrane Scaffolded Desorption Electrospray Ionization-Ion Mobility-Imaging Mass Spectrometry and Unsupervised SegmentationAnalytical Chemistry, 2019
- DESI Spray Stability in the Negative Ion Mode Is Dependent on Relative HumidityJournal of the American Society for Mass Spectrometry, 2018
- Humidity Affects Relative Ion Abundance in Direct Analysis in Real Time Mass Spectrometry of Hexamethylene Triperoxide DiamineAnalytical Chemistry, 2014
- Effect of internal and external conditions on ionization processes in the FAPA ambient desorption/ionization sourceAnalytical and Bioanalytical Chemistry, 2014
- Development of capabilities for imaging mass spectrometry under ambient conditions with desorption electrospray ionization (DESI)International Journal of Mass Spectrometry, 2007
- Ambient mass spectrometry using desorption electrospray ionization (DESI): instrumentation, mechanisms and applications in forensics, chemistry, and biologyJournal of Mass Spectrometry, 2005
- Versatile New Ion Source for the Analysis of Materials in Open Air under Ambient ConditionsAnalytical Chemistry, 2005