Hemodynamics of Saline Flushing in Endoscopic Imaging of Partially Occluded Coronary Arteries
Authors:
- 8 January 2024
- journal article
- research article
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 15 (2) , 211-223
Abstract
Purpose Intravascular endoscopy can aid in the diagnosis of coronary atherosclerosis by providing direct color images of coronary plaques. The procedure requires a blood-free optical path between the catheter and plaque, and achieving clearance safely remains an engineering challenge. In this study, we investigate the hemodynamics of saline flushing in partially occluded coronary arteries to advance the development of intravascular forward-imaging catheters that do not require balloon occlusion. Methods In-vitro experiments and CFD simulations are used to quantify the influence of plaque size, catheter stand-off distance, saline injection flowrate, and injection orientation on the time required to achieve blood clearance. Results Experiments and simulation of saline injection from a dual-lumen catheter demonstrated that flushing times increase both as injection flow rate (Reynolds number) decreases and as the catheter moves distally away from the plaque. CFD simulations demonstrated that successful flushing was achieved regardless of lumen axial orientation in a 95% occluded artery. Flushing time was also found to increase as plaque size decreases for a set injection flowrate, and a lower limit for injection flowrate was found to exist for each plaques size, below which clearance was not achieved. For the three occlusion sizes investigated (90, 95, 97% by area), successful occlusion was achieved in less than 1.2 s. Investigation of the pressure fields developed during injection, highlight that rapid clearance can be achieved while keeping the arterial overpressure to < 1 mmHg. Conclusions A dual lumen saline injection catheter was shown to produce clearance safely and effectively in models of partially occluded coronary arteries. Clearance was achieved across a range of engineering and clinical parameters without the use of a balloon occlusion, providing development guideposts for a fluid injection system in forward-imaging coronary endoscopes.Keywords
Funding Information
- NIH (1R43HL139323-01)
- National Science Foundation (GCR 2120774)
- CoMotion, University of Washington
This publication has 43 references indexed in Scilit:
- The use of central venous catheters for intravenous contrast injection for CT examinationsBritish Journal of Radiology, 2011
- Evaluation of Contrast Agents for Enhanced Visualization in Optical Coherence TomographyInvestigative Ophthalmology & Visual Science, 2010
- Crossing of a calcified “balloon uncrossable” coronary chronic total occlusion facilitated by a laser catheterInternational Journal of Cardiology, 2010
- Scanning fiber endoscopy with highly flexible, 1 mm catheterscopes for wide‐field, full‐color imagingJournal of Biophotonics, 2010
- Detection of Vulnerable Coronary Plaques by Color Fluorescent AngioscopyJACC: Cardiovascular Imaging, 2010
- Expert review document on methodology, terminology, and clinical applications of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosisEuropean Heart Journal, 2009
- Implication of Plaque Color Classification for Assessing Plaque VulnerabilityJACC: Cardiovascular Interventions, 2008
- Update on Coronary Angioscopy: Review of a 20‐Year Experience and Potential Application for Detection of Vulnerable PlaqueJournal of Interventional Cardiology, 2006
- Pathophysiology of Coronary Artery DiseaseCirculation, 2005
- Use of a perforated balloon catheter to deliver concentrated heparin into the wall of the normal canine arteryJACC, 1990