MBMichael Barbour

Michael Barbour

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Michael Barbour has a total of 70 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Patient‐Specific Computational Fluid Dynamics Modeling of Airway Collapse in Infants With Robin Sequence

    by Gautam Jalori, Michael Barbour, Michael Bindschadler, Kelly Evans, Jake Dahl, Alberto Aliseda

    Robin Sequence (RS) is a congenital condition in which patients experience dynamic, periodic obstruction or collapse of the upper airway due to an underdeveloped jaw and a posteriorly displaced tongue. Current clinical techniques for evaluating airway obstruction do not provide quantifiable data and fail to account for the dynamic nature of obstruction or collapse. There is no standardized criterion to characterize obstruction or collapse severity. This study presents the first method that extracts airway motion from 4‐dimensional computed tomography and performs a patient‐specific, moving‐mesh computational fluid dynamics (CFD) analysis of RS patients with complete airway collapse or obstruction. To quantify the effects of airway collapse, airflow dynamics are analyzed using both instantaneous metrics (velocity, pressure, and energy dissipation rate) and cycle‐averaged metrics (resistive work of breathing). These results are compared between a collapsing airway and its synthetic non‐collapsing counterpart. To validate the synthetic non‐collapsing case, it is further compared with a patient‐specific non‐collapsing airway. The results show that, to achieve the same tidal volume, the collapsing case requires significantly greater computed breathing effort (7.55 mJ/cycle) than the synthetic non‐collapsing case (3.68 mJ/cycle). The shorter inspiration time due to the collapse leads to a higher inlet velocity, resulting in 1.7 times the maximum velocity during peak inspiration (just prior to collapse) and a 2.7‐fold higher pressure drop in the collapsing case compared to the synthetic non‐collapsing case. At the onset of collapse, a sharp spike in localized energy dissipation rate is observed due to the abrupt deceleration and dissipation of peak flow velocities. This methodology provides a novel approach to understanding the airflow dynamics of RS patients with airway collapse. It enables quantitative comparison between collapsing and non‐collapsing airways, thereby offering the potential to support more informed and objective clinical decision‐making.

  • Design and Fabrication of the Orthodontic Airway Plate Appliance for Neonates with Pierre Robin Sequence Utilizing Virtual Simulation and 3D-Printing

    by Marielena Layuno-Matos, Michael Barbour, Ezgi Mercan, Geoffrey M. Greenlee, Sheng Zhou, Hannah Case, Kayen Tang, Jeffrey Otjen, Seth Friedman, Kelly N. Evans, et al.

    Objective: Present the workflow and the use of simulation in designing and fabricating an optimal orthodontic airway plate (OAP) to treat patients with Robin sequence (RS) at a pediatric hospital. Design: Narrative description of the workflow, materials, and steps employed to design the OAP appliance for neonates with RS and upper airway obstruction (UAO). Case report of two patients with varying degrees of complexity of RS treated with this therapy. Setting: Dental and bioengineering laboratory, neonatal intensive care unit, and acute care units of a United States tertiary pediatric hospital. Patients, Participants: Syndromic and non-syndromic neonates with RS and severe tongue-based UAO not stabilized with positioning. Interventions: OAP therapy Main Outcome Measure(s): Delivery of an optimal OAP appliance that effectively displaces the tongue forward and relieves UAO. Results: Thirty months after the implementation of the OAP program at our institution, 26 infants with RS had an OAP fabricated and delivered utilizing our existing workflow. With the inclusion of simulation and 3D-printed bending guides, the mean time for appliance fabrication was 5 days, with seven patients requiring multiple delivery attempts. Two patients had pharyngeal tissue trauma related to device malposition or dislodgement. Conclusions: The multidisciplinary collaboration involved in developing our institution's workflow with simulation enhanced the safety and efficiency of our OAP program, enabling the successful delivery of this appliance to 26 infants.


  • Descriptive Summary and Experience Introducing the Orthodontic Airway Plate to Treat Upper Airway Obstruction for Infants With Robin Sequence

    by Hannah F. Case, Marielena Layuno Matos, Kayen Tang, Lindsay Boven, Kara Brodie, Michael Barbour, Lindsey Benedict, Zeenia C. Billimoria, Randall Bly, Tracy Brundage, et al.

    Objectives: (1) Provide our narrative experience treating patients with Robin Sequence (RS) with our orthodontic airway plate (OAP) protocol and (2) report initial patient outcomes. A secondary objective is to share OAP clinician survey results. Design: (1) Narrative experience of a care pathway for neonates with RS and upper airway obstruction (UAO). (2) Retrospective review of initial series of patients with RS treated with this pathway. A clinician survey was also administered. Setting: Neonatal intensive care unit and acute care units of a tertiary children's hospital, with continuity outpatient multidisciplinary craniofacial clinic care. Patients and Participants: Neonates with RS and severe base of tongue UAO not stabilized with positioning, and without mechanical ventilation, profound dysphagia, or microstomia. Interventions: Adapt an OAP clinical pathway Main Outcome Measure(s): Lessons learned, clinical course, and respiratory metrics. Results: In August 2023, our institution launched an OAP treatment pathway. Lessons learned highlight the importance of multidisciplinary communication, patient selection, and patience. Nine patients completed OAP therapy. oAHI values improved from mean 71/h (range 16-189, SD 55.1) to mean oAHI 7.9/h (range 1.1-12.7, SD 3.8). Pretreatment, 7 patients were on high-flow nasal cannula, one each on low-flow nasal cannula and continuous positive airway pressure. All OAP graduates advanced to room air. Clinician survey results suggested high OAP care preparedness and satisfaction. Conclusions: The OAP can be introduced in new setting and delivered as a safe and effective nonsurgical intervention for UAO in RS. Interdisciplinary collaboration is key to treatment success. Infants undergoing OAP treatment can safely discharge home and experience sustained respiratory improvements.


  • Dynamic Airway CT for Morphometric Analysis of Pediatric Tracheomalacia Throughout Respiration

    by Hannah F. Case, Michael Bindschadler, Michael Barbour, Tanya Meyer, John P. Dahl, Seth D. Friedman, Alberto Aliseda, Randall A. Bly

    Dynamic airway computed topography (4D‐CT) can be used to evaluate the trachea in pediatric patients with tracheomalacia. The 4D‐CT enables objective and quantitative evaluation throughout all phases of respiration; however, current systems focus on qualitative review of generated 4D images. Few analytic workflows are available to assist in the extraction of the quantitative geomorphic data generated. In this study, we share a protocol developed within the 3D Slicer framework that performs semi‐automatic tracheal segmentation and subsequent geomorphic analysis. This methodology is applied to 4 sample cases with varying degrees of tracheal collapse throughout all phases of respiration to demonstrate output of cross‐sectional area, aspect ratio (defined as the ratio between minor‐to‐major luminal axis lengths), and tracheal volume (bound by the subglottis and carina) metrics.


  • Structure From Motion Reconstruction of the Pediatric Larynx: A Clinical Case Series

    by Michael C. Barbour, Shaunak N. Amin, Hannah F. Case, Seth D. Friedman, Francisco A. Perez, Randall A. Bly, Kaalan E. Johnson, Sanjay R. Parikh, Clare M. Richardson, John P. Dahl, et al.

    Objective: Endoscopy is the gold‐standard diagnostic modality for many pediatric airway disorders but does not enable quantitative assessment of airway morphology. In a series of pediatric patients, we aim to demonstrate that structure from motion (SfM) photogrammetry, a computer‐vision algorithm, can accurately reconstruct three‐dimensional (3D) models of laryngeal anatomy directly from bronchoscopy videos.Study Design: Prospective case series.Setting: Tertiary academic pediatric hospital.Methods: Pediatric patients undergoing direct laryngoscopy/bronchoscopy and same‐day neck and chest computed tomography (CT) as a part of clinical care were recruited. Optical calibration of the imaging system occurred after each bronchoscopy. SfM was used to reconstruct 3D surfaces from bronchoscopy videos. SfM‐reconstructed surfaces were compared against CT‐derived geometries to determine reconstruction accuracy at glottic and subglottic levels.Results: SfM reconstruction was successfully completed for all four patients. Circular equivalent diameter (DCE) of cross‐sectional area slices measured from SfM‐reconstructed airways was highly accurate compared to DCE measured from the gold‐standard CT scans, with root mean squared error of 0.1, 0.375, and 0.225 mm at the glottis, proximal subglottis, and distal subglottis subsites, respectively. This represents average percent errors of 2%, 4%, and 4%, for each site, respectively.Conclusion: We demonstrate the feasibility of reconstructing laryngeal anatomy with high fidelity from SfM photogrammetry in a clinical series of pediatric patients. This reproducible method provides highly accurate anatomic models directly from endoscopy, enabling quantitative assessment without CT scanning and radiation exposure. This approach has the potential to impact many areas of otolaryngology, including virtual surgical planning, simulation, and family counseling.


  • Synthetic vascular graft that heals and regenerates

    by Le Zhen, Elina Quiroga, Sharon A. Creason, Ningjing Chen, Tanmay R. Sapre, Jessica M. Snyder, Sarah L. Lindhartsen, Brendy S. Fountaine, Michael C. Barbour, Syed Faisal, et al.


  • Hemodynamics of Saline Flushing in Endoscopic Imaging of Partially Occluded Coronary Arteries

    by Syed Faisal, Michael Barbour, Eric J. Seibel, Alberto Aliseda

    Purpose Intravascular endoscopy can aid in the diagnosis of coronary atherosclerosis by providing direct color images of coronary plaques. The procedure requires a blood-free optical path between the catheter and plaque, and achieving clearance safely remains an engineering challenge. In this study, we investigate the hemodynamics of saline flushing in partially occluded coronary arteries to advance the development of intravascular forward-imaging catheters that do not require balloon occlusion. Methods In-vitro experiments and CFD simulations are used to quantify the influence of plaque size, catheter stand-off distance, saline injection flowrate, and injection orientation on the time required to achieve blood clearance. Results Experiments and simulation of saline injection from a dual-lumen catheter demonstrated that flushing times increase both as injection flow rate (Reynolds number) decreases and as the catheter moves distally away from the plaque. CFD simulations demonstrated that successful flushing was achieved regardless of lumen axial orientation in a 95% occluded artery. Flushing time was also found to increase as plaque size decreases for a set injection flowrate, and a lower limit for injection flowrate was found to exist for each plaques size, below which clearance was not achieved. For the three occlusion sizes investigated (90, 95, 97% by area), successful occlusion was achieved in less than 1.2 s. Investigation of the pressure fields developed during injection, highlight that rapid clearance can be achieved while keeping the arterial overpressure to < 1 mmHg. Conclusions A dual lumen saline injection catheter was shown to produce clearance safely and effectively in models of partially occluded coronary arteries. Clearance was achieved across a range of engineering and clinical parameters without the use of a balloon occlusion, providing development guideposts for a fluid injection system in forward-imaging coronary endoscopes.

  • Fluid dynamics in intracranial aneurysms treated with flow-diverting stents: effect of multiple geometrical parameters

    by Fanette Chassagne, Michael C. Barbour, Michael R. Levitt, Alberto Aliseda

    Characterizing the haemodynamics in intracranial aneurysms is of high interest as it impacts aneurysm growth, rupture and treatment, especially with flow-diverting stents (FDS). Flow in these geometries is known to depend on the Dean, Reynolds and Womersley numbers, $De$ , $Re$ , $Wo$ , but is also influenced by geometrical parameters such as the sac shape or the size of the opening. Via particle image velocimetry, this parametric study aimed at evaluating the combined effects of $Re$ , $De$ , $Wo$ and the geometry of the aneurysmal sac on the haemodynamics before and after treatment with FDS. Eight ellipsoidal idealized aneurysm models were created with two curvatures of the parent vessel, two aspect ratios of the sac and two neck sizes. Before treatment, a single counter-rotating vortex, whose strength increases with $Re$ and $De$ , as well as with the neck size and the aspect ratio, was observed in the sac for all but one geometry. After treatment with FDS, four different flow topologies were observed, depending on the geometry: no separation, separation for part of the cycle, two opposing vortices or a single counter-rotating vortex. A linear model with interaction revealed the predominant effect of $De$ and the curvature of the parent vessel on the haemodynamics before and after treatment. This work once more demonstrated the primary role of haemodynamics in the treatment of intracranial aneurysms with FDS. Future work will consider the complexity of patient-specific geometries, and their effects on both the haemodynamics in the sac and the porosity of the FDS.


  • Open Access

    P-016 Lagrangian trajectory simulations with synchrotron microtomography improves hemodynamic analysis of intracranial aneurysms treated with flow diverting stents

    by D Bass, L Marsh, V Chivukula, M Barbour, P Fillingham, L Kim, A Aliseda, M Levitt

    Background Successful treatment of cerebral aneurysms with flow diverting stents (FDS) depends upon altering biomechanical forces to precipitate stable thrombus formation. Computational fluid dynamics (CFD) simulations can model such forces for treatment outcome prediction, and particle tracking methods can simulate the behavior of components of blood such as platelets. Previous work using a porous medium (PM) to simulate the stent surface demonstrated changes in particle tracking metrics following treatment.(1) However, the fidelity of the PM representation of the stent (and its effect on intraaneurysmal blood flow) has not been established, and previous studies of PM methods for aneurysm coils suggest the potential for inaccuracies.(2) Thus, the goal of this study is to perform CFD and particle tracking in simulations of patient-specific aneurysms before and after FDS treatment, and evaluate the accuracy of the PM method compared to actual FDS geometry. Method Data were collected from patients with unruptured intracranial aneurysms treated with FDS. Three-dimensional reconstructions of patient blood vessels were created from rotational angiography and segmented for CFD simulations. A porous layer with face permeability, pressure-jump coefficient, and thickness corresponding to the geometry of the FDS was applied across the aneurysm neck in each patient. To provide a ground truth, each patients’ segmented arterial anatomy was used to 3D-print optically-clear silicone phantoms. Each phantom was treated with an FDS that was deployed by an experienced neurosurgeon and replicated the patient’s in vivo treatment. Phantoms were then imaged by microtomography to obtain high resolution volumetric reconstructions of the implanted FDS. Simulations were run for both the PM and microtomography FDS conditions in each patient, with patient-specific boundary conditions derived from endovascular measurements of blood flow and velocity obtained before and after treatment. Massless particles injected into these simulations were individually tracked to calculate particle tracking metrics, such as residence time and shear stress history. The hemodynamic results were compared between the PM and microtomographic simulations. Results Nine subjects have undergone microtomography, with a goal of 25 subjects total for the study. We anticipate that the PM method will exaggerate the effects of treatment on residence time and shear stress history in comparison to the ground truth microtomography simulations. The inaccuracy of the PM method will be quantified, and corrective factors derived for application in future CFD studies. Conclusions Appreciating how endovascular therapies alter fluid biomechanics is critical to understanding what hemodynamic changes are needed to achieve treatment success. Improving the accuracy of the computational representation of endovascular treatment devices will increase the confidence and clinical utility of these methods. 1. Marsh LMM, Barbour MC, Chivukula VK, Chassagne F, Kelly CM, Levy SH, et al. Platelet Dynamics and Hemodynamics of Cerebral Aneurysms Treated with Flow-Diverting Stents. Ann Biomed Eng. 2019;September. 2. Chivukula VK, Marsh L, Chasagne F, Barbour M, Kelly C, Levy S, et al. Lagrangian Trajectory Simulation of Platelets and Synchrotron Microtomography Augment Hemodynamic Analysis of Intracranial Aneurysms Treated with Embolic Coils. J Biomech Eng. 2021;July. Disclosures D. Bass: None. L. Marsh: None. V. Chivukula: None. M. Barbour: None. P. Fillingham: None. L. Kim: None. A. Aliseda: None. M. Levitt: 1; C; Medtronic: Investigator-initiated unrestricted educational grant, Stryker: Investigator-initiated unrestricted educational grant. 2; C; Medtronic, Stereotaxis. 4; C; Fluid Biomed. 5; C; Metis Innovative, Aeaean Advisors. 6; C; JNIS and Frontiers in Surgery Editorial Boards.

  • Open Access

    O-071 Estimation of optimal coil packing density using lagrangian particle tracking

    by D Bass, L Marsh, M Barbour, V Chivukula, P Fillingham, L Kim, A Aliseda, M Levitt

    Background Aneurysm coil packing density has been studied as a surrogate for treatment outcome, but clinical results are conflicting. Previous work applying computational fluid dynamics simulations to coil embolization of cerebral aneurysms found that embolization increases residence time (RT) and lowers cumulative shear (shear history; SH) of blood components within the aneurysm dome, suggesting that embolization promotes clot formation via a low shear stress-mediated pathway associated with stagnation of flow.1 The goal of this investigation is to determine whether RT and SH can be used to identify optimal coil packing density for coiled cerebral aneurysm outcome prediction, using particle tracking simulations. Method Computational fluid dynamics simulations of patient-specific aneurysms were performed before and after coil embolization treatment. Massless particles were virtually injected and individually tracked in each simulation, and blood flow was simulated with patient-specific boundary conditions. The coil mass was treated as a porous medium with a porosity corresponding to the in vivo treatment packing density. Simulations were also run with porosities corresponding to 50%, 150%, and 200% of the in vivo treatment packing density for each subject. Results Five subjects were included. The relative decrease in the rate of particles entering an aneurysm had a strong correlation with increasing packing density (R2 = 0.944, P < 0.001). A packing density of approximately 33.3% resulted in approximately a 70% reduction in particles entering the aneurysm. Above this packing density, the absolute number of particles was considered to be too low to be statistically reliable, and therefore further particle tracking analyses focused on simulations with packing densities less than 33.3%. Within these simulations, increasing packing density was associated with a linear increase in RT (R2 = 0.462, P < 0.003) and a decrease in SH (R2 = 0.547, P < 0.001), with SH nearing 0 as packing density approached 33.3%. Conclusions The results show that increasing packing density has a predictable effect on biologically relevant metrics calculated via computational fluid dynamics with particle tracking. These changes are thought to reflect alterations in the biomechanical microenvironment that promote stable thrombus formation, which is critical for the success of endovascular therapies. Our results suggest that the maximal hemodynamic effects of packing density may be achieved near a 33.3% threshold. Reference Bass DI, Marsh LMM, Fillingham P, Lim D, Chivukula VK, Kim LJ, et al. Modeling the mechanical microenvironment of coiled cerebral aneurysms. J Biomech Eng. 2023;145(4):1-8. Disclosures D. Bass: None. L. Marsh: None. M. Barbour: None. V. Chivukula: None. P. Fillingham: None. L. Kim: None. A. Aliseda: None. M. Levitt: 1; C; Medtronic: Investigator-initiated unrestricted educational grant; consultant Stryker: Investigator-initiated unrestricted educational grant, Stryker: Investigator-initiated unrestricted educational grant. 2; C; Medtronic, Stereotaxis, Metis Innovative. 4; C; Fluid Biomed. 5; C; Aeaean Advisers. 6; C; JNIS and Frontiers in Surgery Editorial Boards.