Thrombotic and bleeding events are the most common hematologic complications in patients with mechanically assisted circulation and are closely related to device-induced platelet dysfunction. In this study, we sought to link computational fluid dynamics (CFD) modeling of blood pumps with device-induced platelet defects. Fresh human blood was circulated in circulatory loops with four pumps (CentriMag, HVAD, HeartMate II, and CH-VAD) operated under a total of six clinically representative conditions. Blood samples were collected and analyzed for glycoprotein (GP) IIb/IIIa activation and receptor shedding of GPIbα and GPVI. In parallel, CFD modeling was performed to characterize the blood flow in these pumps. Numerical indices of platelet defects were derived from CFD modeling incorporating previously derived power-law models under constant shear conditions. Numerical results were correlated with experimental results by regression analysis. The results suggested that a scalar shear stress of less than 75 Pa may have limited contribution to platelet damage. The platelet defect indices predicted by the CFD power-law models after excluding shear stress <75 Pa correlated excellently with experimentally measured indices. Although numerical prediction based on the power-law model cannot directly reproduce the experimental data. The power-law model has proven its effectiveness, especially for quantitative comparisons.Keywords
This publication has 39 references indexed in Scilit:
- Eighth annual INTERMACS report: Special focus on framing the impact of adverse eventsThe Journal of Heart and Lung Transplantation, 2017
- Flow features and device‐induced blood trauma in CF‐VADs under a pulsatile blood flow condition: A CFD comparative studyInternational Journal for Numerical Methods in Biomedical Engineering, 2017
- Activation and shedding of platelet glycoprotein IIb/IIIa under non-physiological shear stressMolecular and Cellular Biochemistry, 2015
- Computational simulations of flow dynamics and blood damage through a bileaflet mechanical heart valve scaled to pediatric size and flowJournal of Biomechanics, 2014
- Platelet glycoprotein Ibα ectodomain shedding and non-surgical bleeding in heart failure patients supported by continuous-flow left ventricular assist devicesThe Journal of Heart and Lung Transplantation, 2014
- An analysis of pump thrombus events in patients in the HeartWare ADVANCE bridge to transplant and continued access protocol trialThe Journal of Heart and Lung Transplantation, 2014
- Results of the Post-U.S. Food and Drug Administration-Approval Study With a Continuous Flow Left Ventricular Assist Device as a Bridge to Heart TransplantationJACC, 2011
- Multicenter Evaluation of an Intrapericardial Left Ventricular Assist SystemJACC, 2011
- Pathologic high shear stress induces apoptosis events in human plateletsBiochemical and Biophysical Research Communications, 2004
- Fluid mechanics of arterial stenosis: Relationship to the development of mural thrombusAnnals of Biomedical Engineering, 1997