Latest Publications

  • Open Access

    Platelet Adhesion Dynamics Following High Mechanical Shear Stress Exposure: Distinct Mechanisms and a Unified Kinetic Framework

    by Dong Han, Shigang Wang, Wenji Sun, Kiersten P. Clark, Bartley P. Griffith, Zhongjun Wu

    Background: Platelet adhesion to collagen and von Willebrand factor (VWF) is essential for primary hemostasis. High mechanical shear stress (HMSS) generated by blood pumps induces blood damage that is strongly associated with hemostatic disorders in patients receiving mechanical circulatory support (MCS). However, the dynamic process of platelet adhesion and thrombus formation following HMSS exposure remains poorly understood.Methods: Fresh healthy human blood was circulated in an in vitro blood pump loop under clinically relevant operating conditions. Baseline blood and HMSS-exposed blood collected after 2 and 4 h were perfused through collagen- or VWF-coated microfluidic channels for real-time visualization and quantitative analysis of platelet adhesion. Platelet activation, platelet receptor expression, and VWF degradation were also evaluated.Results: On collagen-coated surfaces, normal platelets readily adhered and progressively formed enlarging, stable thrombi. In contrast, HMSS-exposed platelets formed predominantly smaller aggregates and showed a progressive loss of large thrombi. On VWF-coated surfaces, platelets adhered predominantly as individual cells, while HMSS exposure increased platelet translocation, indicating reduced adhesion stability. Despite these distinct adhesion phenotypes and different degrees of HMSS-induced blood damage, the temporal evolution of platelet accumulation under all experimental conditions was consistently described by the same first-order saturation relationship.Conclusions: HMSS-induced blood damage differentially impairs platelet adhesive function by limiting thrombus propagation on collagen while weakening platelet–VWF interactions. A simple kinetic framework is introduced to describe the temporal evolution of platelet accumulation, providing a quantitative tool for evaluating platelet adhesive function and the hemocompatibility of MCS devices.

  • Open Access

    Predicting Device‐Induced Platelet Damage in Assisted Circulation Using a New Biophysical Model and Experimental Validation

    by Anik Tarafder, Dong Han, Bartley P. Griffith, Zhongjun J. Wu

    Background: Platelet activation and receptor shedding caused by non‐physiological shear stress remain a critical challenge in the design and clinical performance of circulatory assist devices. Computational fluid dynamics (CFD)‐based approaches have been widely used by coupling flow‐derived scalar shear stress with empirical damage models to predict platelet activation. In this study, we evaluate the effectiveness of our recently proposed biophysical damage model for predicting platelet activation and receptor shedding caused by circulatory assist devices. Methods: Four rotary blood pumps have been chosen for this study: One axial pump (HeartMate II) and three centrifugal pumps (HeartMate 3, BrioVAD, and CentriMag). CFD simulations were performed under three clinically relevant circulatory support conditions: HeartMate II, HeartMate 3, BrioVAD at a pressure head of 75 mmHg, along with CentriMag at pressure heads of 75, 150, and 350 mmHg. The resulting platelet damage indices were compared with experimentally measured platelet activation (PAC‐1 expression) and receptor shedding (GPIbα and GPVI) data. Results: HeartMate 3, BrioVAD, and CentriMag operating at 75 mmHg caused the lowest levels of platelet activation and receptor shedding, while CentriMag, operating at 350 mmHg, produced the highest, 10 times more activation, and six times more receptor shedding compared to at 75 mmHg. Strong correlations were observed between CFD predicted and in vitro data for all biomarkers (), with the highest agreement observed for GPVI shedding (). Conclusion: The biophysical model preserved the relative trends observed previously with the power‐law formulation, while demonstrating improved agreement with experimental data.

  • A New Multifunction Oxygenator With a Dual-Chamber Gas Exchanger to Reduce Dependence on Oxygen Supply

    by Dong Han, Jiafeng Zhang, Aakash Shah, Bartley P. Griffith, Zhongjun J. Wu

    Although extracorporeal membrane oxygenation (ECMO) systems have been used to provide temporary support for patients with severe respiratory or cardiac failure, they are often bedridden, in part because of their bulky size which relies solely on an unlimited source of wall oxygen. However, there is an unmet clinical need for ambulatory ECMO which necessitates downsizing the ECMO system. We sought to develop a new oxygenator to reduce the dependence on the oxygen supply source. The proposed oxygenator features a dual-chamber gas exchangers, with one chamber primarily responsible for carbon dioxide removal using ambient air and a subsequent chamber primarily responsible for oxygen transfer using pure oxygen. Computational fluid dynamics was used to analyze the blood flow field to avoid adverse stagnation and optimize gas exchange performance. Bovine blood was used for in vitro gas transfer test. This new oxygenator demonstrated the capability to provide adequate respiratory support (both carbon dioxide removal and oxygen transfer) to adult patients at blood rate of 4–6 L/min with an oxygen supply of only 2 L/min. The reduced use of oxygen with this new oxygenator may pave the way for the development of potable ECMO systems.


  • Linking Computational Fluid Dynamics Modeling to Device-Induced Platelet Defects in Mechanically Assisted Circulation

    by Jiafeng Zhang, Dong Han, Zengsheng Chen, Shigang Wang, Wenji Sun, Bartley P. Griffith, Zhongjun J. Wu

    Thrombotic and bleeding events are the most common hematologic complications in patients with mechanically assisted circulation and are closely related to device-induced platelet dysfunction. In this study, we sought to link computational fluid dynamics (CFD) modeling of blood pumps with device-induced platelet defects. Fresh human blood was circulated in circulatory loops with four pumps (CentriMag, HVAD, HeartMate II, and CH-VAD) operated under a total of six clinically representative conditions. Blood samples were collected and analyzed for glycoprotein (GP) IIb/IIIa activation and receptor shedding of GPIbα and GPVI. In parallel, CFD modeling was performed to characterize the blood flow in these pumps. Numerical indices of platelet defects were derived from CFD modeling incorporating previously derived power-law models under constant shear conditions. Numerical results were correlated with experimental results by regression analysis. The results suggested that a scalar shear stress of less than 75 Pa may have limited contribution to platelet damage. The platelet defect indices predicted by the CFD power-law models after excluding shear stress <75 Pa correlated excellently with experimentally measured indices. Although numerical prediction based on the power-law model cannot directly reproduce the experimental data. The power-law model has proven its effectiveness, especially for quantitative comparisons.