High mean entropy calculated from cardiac MRI texture analysis is associated with antitachycardia pacing failure
Open Access
- 29 May 2020
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 43 (7) , 737-745
Abstract
Background: Antitachycardia pacing (ATP), which may avoid unnecessary implantable cardioverter‐defibrillator (ICD) shocks, does not always terminate ventricular arrhythmias (VAs). Mean entropy calculated using cardiac magnetic resonance texture analysis (CMR‐TA) has been shown to predict appropriate ICD therapy. We examined whether scar heterogeneity, quantified by mean entropy, is associated with ATP failure and explore potential mechanisms using computer modeling.Methods: A subanalysis of 114 patients undergoing CMR‐TA where the primary endpoint was delivery of appropriate ICD therapy (ATP or shock therapy) was performed. Patients receiving appropriate ICD therapy (n = 33) were dichotomized into “successful ATP” versus “shock therapy” groups. In silico computer modeling was used to explore underlying mechanisms.Results: A total of 16 of 33 (48.5%) patients had successful ATP to terminate VA, and 17 of 33 (51.5%) patients required shock therapy. Mean entropy was significantly higher in the shock versus successful ATP group (6.1 ± 0.5 vs 5.5 ± 0.7, P = .037). Analysis of patients receiving ATP (n = 22) showed significantly higher mean entropy in the six of 22 patients that failed ATP (followed by rescue ICD shock) compared to 16 of 22 that had successful ATP (6.3 ± 0.7 vs 5.5 ± 0.7, P = .048). Computer modeling suggested inability of the paced wavefront in ATP to successfully propagate from the electrode site through patchy fibrosis as a possible mechanism of failed ATP.Conclusions: Our findings suggest lower scar heterogeneity (mean entropy) is associated with successful ATP, whereas higher scar heterogeneity is associated with more aggressive VAs unresponsive to ATP requiring shock therapy that may be due to inability of the paced wavefront to propagate through scar and terminate the VA circuit.Keywords
This publication has 24 references indexed in Scilit:
- A Systematic Review and Meta-analysis of the Association Between Implantable Cardioverter-Defibrillator Shocks and Long-term MortalityCanadian Journal of Cardiology, 2015
- Reduction in Inappropriate Therapy and Mortality through ICD ProgrammingNew England Journal of Medicine, 2012
- Structural Heterogeneity Alone Is a Sufficient Substrate for Dynamic Instability and Altered RestitutionCirculation: Arrhythmia and Electrophysiology, 2010
- Differences in effects of electrical therapy type for ventricular arrhythmias on mortality in implantable cardioverter-defibrillator patientsHeart Rhythm, 2010
- Alternans and spiral breakup in a human ventricular tissue modelAmerican Journal of Physiology-Heart and Circulatory Physiology, 2006
- Long-Term Clinical Course of Patients After Termination of Ventricular Tachyarrhythmia by an Implanted DefibrillatorCirculation, 2004
- Antitachycardia Pacing for Ventricular Tachycardia Using Implantable Cardioverter Defibrillators:Pacing and Clinical Electrophysiology, 2004
- Prophylactic Implantation of a Defibrillator in Patients with Myocardial Infarction and Reduced Ejection FractionNew England Journal of Medicine, 2002
- Randomized Comparison of Antiarrhythmic Drug Therapy With Implantable Defibrillators in Patients Resuscitated From Cardiac ArrestCirculation, 2000
- Canadian Implantable Defibrillator Study (CIDS)Circulation, 2000