BSBenjamin Sieniewicz

Benjamin Sieniewicz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Benjamin Sieniewicz has a total of 169 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Feasibility of intraprocedural integration of cardiac CT to guide left ventricular lead implantation for CRT upgrades

    by Justin Gould, Baldeep S. Sidhu, Benjamin J. Sieniewicz, Bradley Porter, Angela W. C. Lee, Orod Razeghi, Jonathan M. Behar, Vishal Mehta, Mark K. Elliott, Daniel Toth, et al.

    Background: Optimal positioning of the left ventricular (LV) lead is an important determinant of cardiac resynchronization therapy (CRT) response.Objective: Evaluate the feasibility of intraprocedural integration of cardiac computed tomography (CT) to guide LV lead implantation for CRT upgrades.Methods: Patients undergoing LV lead upgrade underwent ECG‐gated cardiac CT dyssynchrony and LV scar assessment. Target American Heart Association segment selection was determined using latest non‐scarred mechanically activating segments overlaid onto real‐time fluoroscopy with image co‐registration to guide optimal LV lead implantation. Hemodynamic validation was performed using a pressure wire in the LV cavity (dP/dtmax)).Results: 18 patients (male 94%, 55.6% ischemic cardiomyopathy) with RV pacing burden 60.0 ± 43.7% and mean QRS duration 154 ± 30 ms underwent cardiac CT. 10/10 ischemic patients had CT evidence of scar and these segments were excluded as targets. Seventeen out of 18 (94%) patients underwent successful LV lead implantation with delivery to the CT target segment in 15 out of 18 (83%) of patients. Acute hemodynamic response (dP/dtmax ≥ 10%) was superior with LV stimulation in CT target versus nontarget segments (83.3% vs. 25.0%; p = .012). Reverse remodeling at 6 months (LV end‐systolic volume improvement ≥15%) occurred in 60% of subjects (4/8 [50.0%] ischemic cardiomyopathy vs. 5/7 [71.4%] nonischemic cardiomyopathy, p = .608).Conclusion: Intraprocedural integration of cardiac CT to guide optimal LV lead placement is feasible with superior hemodynamics when pacing in CT target segments and favorable volumetric response rates, despite a high proportion of patients with ischemic cardiomyopathy. Multicentre, randomized controlled studies are needed to evaluate whether intraprocedural integration of cardiac CT is superior to standard care.


  • Open Access

    Real-world experience of leadless left ventricular endocardial cardiac resynchronization therapy: A multicenter international registry of the WiSE-CRT pacing system

    by Benjamin J. Sieniewicz, Timothy R. Betts, Simon James, Andrew Turley, Christian Butter, Martin Seifert, Lucas V.A. Boersma, Sam Riahi, Petr Neuzil, Mauro Biffi, et al.


  • Open Access

    High mean entropy calculated from cardiac MRI texture analysis is associated with antitachycardia pacing failure

    by Justin Gould, Bradley Porter, Baldeep S. Sidhu, Simon Claridge, Zhong Chen, Benjamin J. Sieniewicz, Mark Elliott, Vishal Mehta, Fernando O. Campos, Martin J. Bishop, et al.

    Background: Antitachycardia pacing (ATP), which may avoid unnecessary implantable cardioverter‐defibrillator (ICD) shocks, does not always terminate ventricular arrhythmias (VAs). Mean entropy calculated using cardiac magnetic resonance texture analysis (CMR‐TA) has been shown to predict appropriate ICD therapy. We examined whether scar heterogeneity, quantified by mean entropy, is associated with ATP failure and explore potential mechanisms using computer modeling.Methods: A subanalysis of 114 patients undergoing CMR‐TA where the primary endpoint was delivery of appropriate ICD therapy (ATP or shock therapy) was performed. Patients receiving appropriate ICD therapy (n = 33) were dichotomized into “successful ATP” versus “shock therapy” groups. In silico computer modeling was used to explore underlying mechanisms.Results: A total of 16 of 33 (48.5%) patients had successful ATP to terminate VA, and 17 of 33 (51.5%) patients required shock therapy. Mean entropy was significantly higher in the shock versus successful ATP group (6.1 ± 0.5 vs 5.5 ± 0.7, P = .037). Analysis of patients receiving ATP (n = 22) showed significantly higher mean entropy in the six of 22 patients that failed ATP (followed by rescue ICD shock) compared to 16 of 22 that had successful ATP (6.3 ± 0.7 vs 5.5 ± 0.7, P = .048). Computer modeling suggested inability of the paced wavefront in ATP to successfully propagate from the electrode site through patchy fibrosis as a possible mechanism of failed ATP.Conclusions: Our findings suggest lower scar heterogeneity (mean entropy) is associated with successful ATP, whereas higher scar heterogeneity is associated with more aggressive VAs unresponsive to ATP requiring shock therapy that may be due to inability of the paced wavefront to propagate through scar and terminate the VA circuit.


  • Open Access

    Leadless left ventricular endocardial pacing in nonresponders to conventional cardiac resynchronization therapy

    by Baldeep S. Sidhu, Bradley Porter, Justin Gould, Benjamin Sieniewicz, Mark Elliott, Vishal Mehta, Peter P. H. M. Delnoy, Jean‐Claude Deharo, Christian Butter, Martin Seifert, et al.

    Background: Endocardial pacing may be beneficial in patients who fail to improve following conventional epicardial cardiac resynchronization therapy (CRT). The potential to pace anywhere inside the left ventricle thus avoiding myocardial scar and targeting the latest activating segments may be particularly important. The WiSE‐CRT system (EBR systems, Sunnyvale, CA) reliably produces wireless, endocardial left ventricular (LV) pacing. The purpose of this analysis was to determine whether this system improved symptoms or led to LV remodeling in patients who were nonresponders to conventional CRT.Method: An international, multicenter registry of patients who were nonresponders to conventional CRT and underwent implantation with the WiSE‐CRT system was collected.Results: Twenty‐two patients were included; 20 patients underwent successful implantation with confirmation of endocardial biventricular pacing and in 2 patients, there was a failure of electrode capture. Eighteen patients proceeded to 6‐month follow‐up; endocardial pacing resulted in a significant reduction in QRS duration compared with intrinsic QRS duration (26.6 ± 24.4 ms; P = .002) and improvement in left ventricular ejection fraction (LVEF) (4.7 ± 7.9%; P = .021). The mean reduction in left ventricular end‐diastolic volume was 8.3 ± 42.3 cm3 (P = .458) and left ventricular end‐systolic volume (LVESV) was 13.1 ± 44.3 cm3 (P = .271), which were statistically nonsignificant. Overall, 55.6% of patients had improvement in their clinical composite score and 66.7% had a reduction in LVESV ≥15% and/or absolute improvement in LVEF ≥5%.Conclusion: Nonresponders to conventional CRT have few remaining treatment options. We have shown in this high‐risk patient group that the WiSE‐CRT system results in improvement in their clinical composite scores and leads to LV remodeling.


  • Open Access

    Pacing in proximity to scar during cardiac resynchronization therapy increases local dispersion of repolarization and susceptibility to ventricular arrhythmogenesis

    by Caroline Mendonca Costa, Aurel Neic, Eric Kerfoot, Bradley Porter, Benjamin Sieniewicz, Justin Gould, Baldeep Sidhu, Zhong Chen, Gernot Plank, Christopher A. Rinaldi, et al.


  • Open Access

    Erratum to “Comparison of Echocardiographic and Electrocardiographic Mapping for Cardiac Resynchronisation Therapy Optimisation”

    by Helder Pereira, Tom A. Jackson, Simon Claridge, Jonathan M. Behar, Cheng Yao, Benjamin Sieniewicz, Justin Gould, Bradley Porter, Baldeep Sidhu, Jaswinder Gill, et al.

    [This corrects the article DOI: 10.1155/2019/4351693.].

  • Prolonged lead dwell time and lead burden predict bailout transfemoral lead extraction

    by Justin Gould, Baldeep.S. Sidhu, Bradley Porter, Benjamin. J. Sieniewicz, Thomas Teall, Steven.E. Williams, Anoop Shetty, Paolo Bosco, Christopher Blauth, Jaswinder Gill, et al.

    Background: Transvenous lead extraction (TLE) may be performed by superior approach using the original implant vein or via a femoral approach; however, limited comparative data exists. We compare outcomes between femoral versus nonfemoral TLE approaches and determine predictors of bailout transfemoral lead extraction in patients undergoing initial TLE via the original implant vein by a superior approach.Methods: All consecutive TLEs between October 2000 and March 2018 were prospectively collected (n = 1052). Patients were dichotomized into femoral (n = 118) and nonfemoral (n = 934) groups.Results: Demographics were balanced between femoral vs nonfemoral groups. Patients in the femoral group had significantly higher mean lead dwell times (11.6 ± 9.7 vs 6.6 ± 6.6 years, P < .001), mean number of leads extracted (2.7 ± 1.3 vs 2.0 ± 1.0, P < .001), 30‐day procedure related major complications (including deaths) (8.5% vs 1.1%, P < .001) and emergency thoracotomy rates (4.2% vs 0.7%, P = .007). All‐cause 30‐day mortality rates were similar between groups (3.4% vs 2.0%, P = .315). Prolonged lead dwell time and increased number of leads extracted were predictive of a bailout transfemoral approach at multivariable analysis.Conclusion: Femoral approach TLE is associated with increased risk of 30‐day procedure related major complications but not 30‐day all‐cause mortality. Prolonged lead dwell time and increased number of leads extracted are independent predictors for bailout transfemoral lead extraction. Such patients should be considered high risk of major complications and performed by high‐volume lead extraction centers with experience in multiple approaches and techniques including experience with transfemoral lead extraction.


  • Open Access

    Optimization of CRT programming using non‐invasive electrocardiographic imaging to assess the acute electrical effects of multipoint pacing

    by Benjamin J. Sieniewicz, Tom Jackson, Simon Claridge, Helder Pereira, Justin Gould, Baldeep Sidhu, Bradley Porter, Steve Niederer, Cheng Yao, Christopher A. Rinaldi

    Aim: Quadripolar lead technology and multi‐point pacing (MPP) are important clinical adjuncts in cardiac resynchronization therapy (CRT) pacing aimed at reducing the rate of non‐response to therapy. Mixed results have been achieved using MPP and it is critical to identify which patients require this approach and how to configure their MPP stimulation, in order to achieve optimal electrical resynchronization.Methods & Results: We sought to investigate whether electrocardiographic imaging (ECGi), using the CARDIOINSIGHT™ inverse ECG mapping system, could identify alterations in electrical resynchronization during different methods of device optimization. In no patient did a single form of programming optimization provide the best electrical response. The effects of utilizing MPP were idiosyncratic and highly patient specific. ECGi activation maps were clearly able to discern changes in bulk LV activation during differing MPP programming. In two of the five subjects, MPP resulted in more rapid activation of the left ventricle compared to standard CRT; however, in the remaining three patients, the use of MPP did not appear to acutely improve electrical resynchronization. Crucially, this cohort showed evidence of extensive LV scarring which was well visualized using both CMR and ECGi voltage mapping.Conclusions: Our work suggests a potential role for ECGi in the optimization of non‐responders to CRT, as it allows the fusion of activation maps and scar analysis above and beyond interrogation of the 12 lead ECG.


  • Transvenous lead extraction in patients with cardiac resynchronization therapy devices is not associated with increased 30-day mortality

    by Justin Gould, Magdalena Klis, Bradley Porter, Benjamin J Sieniewicz, Baldeep S Sidhu, Simon Claridge, Steven E Williams, Anoop Shetty, Mark O’Neill, Jaswinder Gill, et al.

    Transvenous lead extraction (TLE) may be necessary due to system infection/erosion or lead malfunction. Cardiac resynchronization therapy (CRT) patients undergoing TLE may be at greater risk due to increased comorbidities. We examined whether patients with CRT systems undergoing TLE had more comorbidities and higher 30-day mortality than those with non-CRT devices. All TLEs between October 2000 and December 2016 were prospectively collected. During this period 925 TLEs occurred (CRT group 231, non-CRT group 694). Cardiac resynchronization therapy patients were older (68.1 ± 10.8 years vs. 64.3 ± 16.1 years, P = 0.024); more likely male (85.7% vs. 69%, P < 0.001); had lower mean left ventricular ejection fraction (34.1 ± 12.7% vs. 48.3 ± 12.9%, P < 0.001); had higher prevalence of renal impairment (33.8% vs. 13.7%, P < 0.001) and were more likely to have ≥2 comorbidities (84% vs. 40.1%, P < 0.001). Mean lead dwell time was lower in the CRT group (5.6 ± 5.5 years vs. 7.6 ± 7.1 years, P = 0.002). There was no significant difference in all-cause 30-day mortality rates between CRT (3.0%, n = 7) and non-CRT patients (2.0%, n = 14) (P = 0.443). The majority of deaths in both groups were due to sepsis. Univariate and multivariate analysis showed age, renal impairment and sepsis were associated with increased risk of 30-day mortality. Transvenous lead extraction of a CRT system did not predict 30-day mortality. Transvenous lead extraction in CRT patients was not associated with increased 30-day mortality when compared with non-CRT patients. Age, renal impairment and sepsis were independent predictors of 30-day mortality. Sepsis was the main cause of 30-day mortality.


  • Open Access

    Is heart failure with mid range ejection fraction (HFmrEF) a distinct clinical entity or an overlap group?

    by Jessica Webb, Jane Draper, Lauren Fovargue, Ben Sieniewicz, Justin Gould, Simon Claridge, Carys Barton, Silapiya Smith, Kristin Tondel, Ronak Rajani, et al.