A new fluoroscopic view for evaluation of anteromedial cortex reduction quality during cephalomedullary nailing for intertrochanteric femur fractures: the 30° oblique tangential projection
Open Access
- 5 November 2020
- journal article
- research article
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 21 (1) , 1-8
Abstract
Background: Anteromedial cortex-to-cortex reduction is a key parameter for stable reconstruction of the fracture fragments during the intertrochanteric fracture fixation. This paper introduces the oblique fluoroscopic projection as a novel method to evaluate the quality of anteromedial cortical apposition.Methods: Three proximal femur specimens were marked with steel wires along five anatomic landmarks: Greater trochanter, Lesser trochanter, Intertrochanteric line, Anterolateral tubercle and the Anteromedial cortical line. After obtaining the standard femoral neck AP and lateral fluoroscopic images, the C-arm was rotated by every 5°increments until a clear tangential view of the antero-medial-inferior corner cortex was observed. 98 cases of intertrochanteric hip fractures were enrolled from April 2018 to October 2019. After fixation with the nails, the intra-operative anteromedial cortex reduction quality was evaluated from the AP, the true lateral, and the new anteromedial oblique fluoroscopic images. The fluoroscopic results were compared with the post-operative 3D-CT reconstruction images.Results: The specimen study showed that internal rotation of the C-arm to approximately 30 ° can remove all the obscure shadows and clearly display the antero-medial-inferior cortical tangent line. Clinically,the positive, neutral and negative apposition of different cortices via intra-operative fluoroscopic images showed79, 19 and 0 cases of medial cortical apposition in AP views; 2, 68 and 28 cases of anterior cortices in lateral views;and 22, 51 and 25cases of anteromedial cortical apposition in oblique views respectively. The post-operative 3D-CT reconstruction images revealed that the final anteromedial cortical contact was noted in 62 cases (63.3%), and lost in 36 cases (36.7%). The overall coincidence rate between intra-operative fluoroscopy and post-operative 3D-CT was 63.3% (62/98) in AP view,79.6% (78/98) in lateral view, and 86.7% (85/98) in oblique view(p < 0.001). Negative cortical apposition in oblique view was highly predictive of a final loss of cortical support on 3D CT (24/25 cases, 96%).And non-negative cortical apposition in oblique view was highly associated with true cortical support on 3D CT images (61/73 cases, 83.6%) (p < 0.001).Conclusions: Besides the AP and lateral projections, an anteromedial oblique view of 30° certifies to be a very useful means for evaluation of the fracture reduction quality of anteromedial cortical apposition.Keywords
Funding Information
- National Natural Science Foundation of China (81772323)
This publication has 18 references indexed in Scilit:
- Anteromedial cortical support reduction in unstable pertrochanteric fractures: a comparison of intra-operative fluoroscopy and post-operative three dimensional computerised tomography reconstructionInternational Orthopaedics, 2017
- Wiring technique for lesser trochanter fixation in proximal IM nailing of unstable intertrochanteric fractures: A modified candy-package wiring techniqueInjury, 2017
- Proximal femoral nails anti-rotation versus dynamic hip screws for treatment of stable intertrochanteric femur fractures: an outcome analyses with a minimum 4 years of follow-upBMC Musculoskeletal Disorders, 2016
- Effect of three remplissage techniques on tendon coverage and shoulder kinematics: a navigated robotic biomechanical studyBMC Musculoskeletal Disorders, 2016
- Fracture reduction with positive medial cortical support: a key element in stability reconstruction for the unstable pertrochanteric hip fracturesArchives of orthopaedic and trauma surgery, 2015
- Prevention of excessive postoperative sliding of the short femoral nail in femoral trochanteric fracturesArchives of orthopaedic and trauma surgery, 2015
- Intramedullary fixation of pertrochanteric hip fractures with the short AO-ASIF proximal femoral nailArchives of orthopaedic and trauma surgery, 2003
- The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip.Journal of Bone and Joint Surgery, 1995
- Unstable intertrochanteric fractures of the hip. Treatment with Ender pins compared with a compression hip-screw.Journal of Bone and Joint Surgery, 1988
- Mechanics of the Treatment of Hip InjuriesClinical Orthopaedics and Related Research, 1980