Lag screw cut-out is one of the major postoperative complications on femoral trochanteric fractures. However, precise analyses of excessive sliding and lag screw cut-out were limited. The purpose of this study was to investigate the factors that induce this unfavorable event. From April 2010 to April 2013, 226 patients were operated in our institute using a short femoral nail. Among them, 177 patients (29 males and 148 females) with a mean age of 84 years (60–97 years), who were followed up >3 months, were included in this study. The postoperative sliding distance, fracture type (AO/OTA classification), tip-apex distance (TAD), reduction pattern in the postoperative X-ray (antero-posterior and lateral views), bone quality (canal flare and cortical indices), walking ability at the time of pre-injury and final follow-up, and complications were investigated retrospectively. The mean sliding distance was 3.7 mm, and one cut-out case (0.6 %) was observed. The sliding distance of the AO/OTA 31-A2 fractures was significantly longer than that of the A1 fractures (p < 0.0001). Regarding the reduction pattern, the sliding distance of the intramedullary type was longer than that of the extramedullary and anatomical types in the lateral view (p < 0.01, p < 0.001, respectively). Further, even in the medial and anatomical types, where the reduction patterns are recommended in the antero-posterior view, the sliding distance of the intramedullary type was significantly longer than that of the anatomical type in the lateral view. There was no correlation of bone quality with the sliding distance. Because the sliding distance increased in the intramedullary type in the lateral view of unstable fractures, an accurate reduction in the lateral view at surgery is important, particularly in unstable fractures.Keywords
This publication has 14 references indexed in Scilit:
- Occurrence of secondary fracture around intramedullary nails used for trochanteric hip fractures: A systematic review of 13,568 patientsInjury, 2012
- Postoperative stability on lateral radiographs in the surgical treatment of pertrochanteric hip fracturesArchives of orthopaedic and trauma surgery, 2012
- PFNA and PFN in Intertrochanteric Fractures - Comparison Study of Sliding -Hip & Pelvis, 2010
- Hip fracture incidence in Japan: estimates of new patients in 2007 and 20-year trendsArchives of Osteoporosis, 2009
- Fracture and Dislocation Classification Compendium - 2007Journal of Orthopaedic Trauma, 2007
- The Anterior and Medial Reduction of Intertrochanteric Fractures: A Simple Method to Obtain a Stable ReductionJournal of Orthopaedic Trauma, 2007
- RAB-Plate versus Sliding Hip Screw for Unstable Trochanteric Hip Fractures: Stability of the Fixation and Modes of Failure???Radiographic Analysis of 218 FracturesThe Journal of Trauma: Injury, Infection, and Critical Care, 2001
- Trochanteric hip fractures Fixation failure commoner with femoral medialization, a comparison of 101 casesActa Orthopaedica, 1996
- The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip.Journal of Bone and Joint Surgery, 1995
- Trochanteric FracturesClinical Orthopaedics and Related Research, 1990