Influence of Occlusal Stress on Implant Abutment Junction and Implant Bone Interface: A Finite Element Analysis Study
- 1 January 2022
- journal article
- research article
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 23 (12) , 1190-1194
Abstract
The aim of the present study was to assess the occlusal stress on the implant-abutment junction and implant-bone interface of a long-span implant-supported prosthesis made of two different prosthetic materials. A computerized tomography of the mandible was used to get the finite element model of the bone. The comparative groups were made as follows: S1 and S2 - 3.7 × 11 mm (44 region) and 4.5 × 11 mm (47 region), S1A and S2A - screw-retained porcelain-fused-to-metal prosthesis, S1B and S2B - cement-retained porcelain-fused-to-metal prosthesis, S1C and S2C - screw-retained zirconia prosthesis, and S1D - cement-retained zirconia prosthesis. Maximum stress generated on the implant-abutment interface of all the prostheses under vertical and oblique load was assessed. For all the comparative groups, maximum level of stress was generated at the cervical level of the implant-bone interface in comparison to the apical and middle-third level under both vertical and oblique load. No statistically significant difference between zirconia and porcelain-fused-to-metal prosthesis was seen at the implant-abutment interface and the cervical third of the implant-bone interface. A significant difference was found between all screw-retained and cement-retained groups. The present study concluded that the short implants in combination with standard-length implants using either porcelain-fused-to-metal or zirconia as prosthetic material in the form of long-span implant-supported prosthesis can be a viable treatment option in the posterior mandible. The accuracy of the diagnosis, examination, and knowledge of the site where the implant must be inserted, and the choice of superstructure is important for the stability and lifespan of the implant prosthesis.Keywords
This publication has 11 references indexed in Scilit:
- Flexural strengths of implant-supported zirconia based bridges in posterior regionsThe Journal of Advanced Prosthodontics, 2014
- Comparison of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible – A computed tomography-based three-dimensional finite element analysisJournal of Biomechanics, 2013
- Short Implants in Partially Edentulous Maxillae and Mandibles: A 10 to 20 Years Retrospective EvaluationInternational Journal of Dentistry, 2012
- Kennedy Classification and Treatment Options: A Study of Partially Edentulous Patients Being Treated in a Specialized Prosthetic ClinicJournal of Prosthodontics, 2012
- From porcelain-fused-to-metal to zirconia: Clinical and experimental considerationsDental Materials, 2011
- An overview of zirconia ceramics: Basic properties and clinical applicationsJournal of Dentistry, 2007
- In vitro effect of load cycling on metal-ceramic cement- and screw-retained implant restorationsThe Journal of Prosthetic Dentistry, 2007
- Screw Loosening for Standard and Wide Diameter Implants in Partially Edentulous Cases: 3- to 7-Year Longitudinal DataImplant Dentistry, 2004
- Randomized clinical trial comparing the efficacy of mandibular implant-supported overdentures and conventional dentures in diabetic patients. Part III: Comparisons of patient satisfactionThe Journal of Prosthetic Dentistry, 1999
- THE EDENTULOUS PREDICAMENT. I: A PROSPECTIVE STUDY OF THE EFFECTIVENESS OF IMPLANT-SUPPORTED FIXED PROSTHESESThe Journal of the American Dental Association, 1996